Q2000A (Voltage) & Q2000B (Current)
The QUANTA Q2000A and Q2000B are a high-quality ±1,999-count DC voltmeter and ammeter, respectively. The base meters are digital indicators for use in electrically-noisy industrial environments. With the addition of analog and control outputs, these meters can provide two-wire current-loop signals to a central control room and provide local alarm or control. A 1/8 DIN case with screw terminals for signal and power is standard. A wide range of options are available. POWER AND DISPLAY OPTIONS The QUANTA Q2000A and Q2000B are available with an LED or an LCD display and with six types of meter power: 120 V ac, 240 V ac, 24 V ac, 5 V dc and 9-32 V dc (isolated) and 26-56 V dc (isolated). ANALOG OUTPUT OPTIONS A 1 mV/count (±2 V full-scale) analog output is standard and is ideal for driving a strip-chart recorder. An additional analog output can be provided by an optional vertical plug-in board. Available output signals are 0-5 V dc, 0-10 V dc, 0-1 mA (source or sink) and 4-20 mA (source or sink). The top and bottom of each output range can be scaled to fit a user-selected display span. CONTROL OUTPUT OPTIONS Additional outputs can be provided by a horizontal upper board. Available options include single-setpoint control with one 10 A relay, dual-setpoint control with two 10 A relays, 4-20 mA proportional control (source or sink), time-proportional 2 A solid-state relay control, and isolated, parallel BCD output. For additional information, please refer to the QUANTA and Mechanical sections. SPECIFICATIONS
ANALOG INPUT Q2000A
ANALOG INPUT Q2000B
INPUT CONFIGURATION Configuration: Bipolar, single-ended Polarity: Automatic Span adjustment: ±4% NOISE REJECTION NMR: 75 dB, 50/60 Hz CMR: 120 dB, DC to 60hZ CMV: 1500 Vp per HV test, 354 Vp per IEC spacing ACCURACY AT 25°C Maximum Error: ±0.05% of reading ±1 count Span tempco: ±0.01% of reading/°C Step response: 1 s to 99.9% of span Warmup to rated accuracy: 10 min CONVERSION Technique: Dual-slope, average-value Signal integration period: 100 ms Read rate: 2.5/s DISPLAY LED: 0.56 in (14.2 mm) 7-segment, red LCD: 0.50 in (12.7 mm) 7-segment liquid crystal Symbols: 1.8.8.8 Decimal point positions: Three positions selectable by jumpers behind lens or at connector Overrange indication: Three-least significant digits blanked POWER AC voltages: 120, 240 or 24 V ac +10%/15% AC frequency: 49-440 Hz DC voltages: 9-32 V dc, isolated to 300 Vp; 26-56 V dc, isolated to 300 Vp; 5 V dc ±5%, non-isolated Power consumption: 8 W max ENVIRONMENTAL Operating temperature: 0 to 60°C Storage temperature: 40 to +85°C Relative humidity: 95% at 40°C (non-condensing) MECHANICAL Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical section for drawings) Weight: 17 oz (480 g) Case material: 94V-0 UL-rated polycarbonate |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2003,
NEWPORT Electronics, Inc. All rights reserved.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||