ADDRESSING
Having received the ETX or XOFF character, then the STX or XON
character, the next character received is the address of the
unit that is to receive data. There are 32 possible addresses,
from code 30 to code 4F hex. These correspond to addresses set
up on the DIP switch jumper on the card. Units with the address,
“0” ASCII 30 hex, will display all data, including the address
code sent, and this address will cause any unit to receive data.
Handshake: No handshake required–accepts continuous data. |
|
PROTOCOLS
The following serial ASCII protocols are jumper switch selectable:
Mode 0: Each printable character as it is received is placed
in the least significant position and all characters are shifted
left one position. Following a carriage return character, the
next valid character received causes the display to clear and
that character is placed in the least significant position (if
it is a printable character).
Mode 1: Printable characters are placed in a buffer on
reception. Receipt of the carriage return character causes the
buffer contents to be transferred to the display.
Mode 2: 269 Temperature Meter display–display is updated
on reception of the carriage return character. When the transmitting
meter is measuring temperatures, the remote display repeats
the four characters shown on the 269, followed by degrees C
or degrees F. When the transmitting 269 is indicating millivolts,
the remote display repeats the four characters in the middle
four positions, and negative indication is in the left hand
position. Overload indication is with E’s.
Mode 3: P6000 Universal Counter (without units of measurement)
Display is updated on reception of the carriage return character.
The display repeats the 6 characters shown on the P5000. The
P5000 must be configured to transmit a 9 character message,
not a 12 character message. |
Recognized Codes–Other Codes Ignored
|
ASCII
Code
|
Keyboard
Character
|
Action
|
|
03
|
Ctrl
C
|
EXT:
stops the display from listening to further data except code
02 |
|
13
|
Ctrl
S
|
XOFF:
same as ETX |
|
02
|
Ctrl
B
|
STX:
starts the display listening to data. If the instrument has
an address other than 0 the next character must be the address
of the instrument or a 0 or it will return to not listening
|
|
11
|
Ctrl
Q
|
XON:
same as STX |
|
0C
|
Ctrl
L
|
Causes
the display to clear blank |
|
0D
|
Ctrl
M or Enter
|
End
of data; in shift mode, next valid data will clear the display
and insert character into least significant position. In strobed
mode, transfers last string to the display. |
|
20
|
Space
|
Inserts
a space |
|
2B
|
+
|
Inserts
a space |
|
2D
|
-
|
Inserts
a ‘–’ sign |
|
2E
|
.
|
Adds
a decimal point to the last character entered |
|
1B
|
Esc
|
Resets
display to its power-on condition |
|
30-5F
|
|
Inserts
characters shown above: character is entered in the least
significant place and all characters are shifted to the left.
In strobed mode the data is placed in a register than than
the display.
|
|