"Cement-On" Thermocouples
CO1 / CO2 / CO3
Features
New Rugged Design
For #6, #8, #10 and 1/4" Screw Sizes
Made from 20 AWG Glass-On-Glass or PFA Insulated Special Limits of Error Wire
Stocked in 12, 24, 36 and 60" Lengths with Stripped End Leads
Rated to 480°C (900°F)
NEWPORT introduces its Cement-On, fast response thermocouples for fast surface temperature measurement applications in three convenient styles. Styles 1 and 2 are made from 0.0005" thermocouple alloy foil by a special process where the butt welded thermocouple junction is 0.0005" in thickness. Styles 1 and 2 are flat, extremely low inertia construction and are an ideal means of measuring the temperature of both flat and curved metals, plastic and ceramic surfaces where very fast response is desired.

NEWPORT's Cement-On Style 1 and 2 thermocouples are fabricated from ANSI "Special Limits of Error" grade thermocouple materials in "K", "E" and "T" calibrations and yield accurate temperature indication when used with standard thermocouple instrumentation. Styles 1 and 2 have the fastest response. Style 3 is an economy version constructed from 0.010" diameter bead welded standard limit of error thermocouple wire. It should be used where extremely fast response is not essential.


To Order (Specify Model No.) Prices Shown in U.S. Dollars
Model No. Price Style Thermocouple Type Length
(inches)
Maximum Temperature °C*
Continuous
600 hr.
600 hr.
CO1-K
$31
1
K CHROMEGA®-ALOMEGA®
36"
260
315
370
CO1-E
$31
E CHROMEGA®-Constantan
36"
260
315
370
CO1-T
$31
T Copper - Constantan
36"
150
205
260
CO2-K
$23
2
K CHROMEGA®-ALOMEGA®
6"
540
540
650
CO2-E
$23
E CHROMEGA®-Constantan
6"
425
425
540
CO2-T
$23
T Copper-Constantan
6"
150
150
260
CO3-J
$17
3
J Iron - Constantan
36"
260
370
370
CO3-K
$17
K CHROMEGA®-ALOMEGA®
36"
260
370
370
CO3-E
$17
E CHROMEGA®-Constantan
36"
260
370
370
CO3-T
$17
T Copper-Constantan
36"
205
260
370
Response time when "grounded" or "cemented" to surface: Style 1 —10 to 20 milliseconds, Style 2 — 2 to 5 milliseconds, Style 3 — 300 milliseconds.
The response time or "time constant" is the time required to reach 63.2% of an instantaneous temperature change. Additional length wire can be ordered for Styles 1 and 3, add $1.50 per foot.


*The temperature range high limits given are greatly influenced by environmental conditions, installation method, accuracy and lifetime requirements and may vary from the general guidelines listed in the table.
Style 1 and 3 cannot be used with CC High Temperature Cement; CC Cement will break down insulation.

Style 1
Cement-On Style 1 thermocouples are the easiest to install. The foil sensor is embedded between two paper thin, glass reinforced high temperature polymer laminates which both support and electrically insulate the foil section as well as provide a flat surface for cementing. The polymer/glass laminate, in general, determines the maximum temperature of the construction which is 260°C continuous and up to 370°C for short duration. Each Style 1 unit includes 3 feet of glass braid insulated 30 gage thermocouple wire which is bonded to the foil and strain relieved by laminate. An application instruction sheet accompanies each packaged Cement-On type thermocouples.
Style 1
Style 2
NEWPORT Cement-On Style 2 thermocouples are recommended where extremely fast surface temperature measurement response time is a requirement. Intimate thermal coupling for this style is achieved by directly bonding the foil junction area to the surface to be measured. For ease of handling, the foil leads come fastened to a polyimide film frame which is tough, flexible, dimensional, stable material rated for 260°C continuous service. During application, the foil thermocouple can be peeled from the frame or released by the application of heat. As an alternate, portions of the frame may be cut away by scissor or knife.

The 6" uninsulated foil leads are of .002" material and thus are fragile and should be handled with care during installation. NOTE: It is imperative that the leads be electrically insulated from each other as well as being mechanically supported. This can be achieved, for example, by laying and brushing the leads into a layer of insulating cement or epoxy. Before doing this on electrically conductive surfaces, it is best to lay down and let dry, a thin layer of the cement to insure that the leads are insulated from the surface. Insulated thermocouple lead wire can be bonded to the foil leads by silver soldering, or resistance welding. Thirty gage, or smaller lead wire is suggested. An application instruction sheet accompanies each package of thermocouples.

Cementing of the junction and lead may be achieved by using NEWPORT CC high temperature cement for temperatures above 260°C; OMEGABOND® OB-101 or OB-200 epoxies for temperatures below 260°C. Please note more care is required to install the Style 2 than Style 1 or 3. It is suggested that at least one additional unit be ordered as some experimentation may be necessary to learn the technique of application for these thermocouples.

Style 2

Style 3
Style 3 thermocouples are constructed of 30 gage (0.010") diameter "Standard Limits of Error" wire. The welded bead thermocouple is embedded in a paper-thin laminate intended for surface applications by bonding with added adhesive. Color-coded, glass braid insulated 36" leads are supplied. Style 3 probes can be used over the range of -190 to 370°C depending on the adhesive or cement used, the time of exposure and the environment.
Style 3

Copyright 2003, NEWPORT Electronics, Inc. All rights reserved.
NEWPORT Newport Home Products Purchase Quotes Pricelist Manuals Site Map Search e-mail Newport Home Products Purchase Quotes Pricelist Manuals Site Map Search e-mail Newport Home