COMMON SPECIFICATIONS - ALL MODELS
SIGNAL OUTPUT
Connection: 2-wire Linear Range: 4-20 mA Maximum Output: 35 mA Voltage Compliance: 9-50 Vdc Power Supply Rejection: 0.01% of span/volt INPUT/OUTPUT PROTECTION CMV, Input to Case or Output: 2100 Vp per HV test, 354 Vp per IEC spacing CMR, Input to Case or Output: 120 dB, DC to 60 Hz NMV Across Output Leads: 120 Vac for 1 min Reverse Polarity Across Output Leads: 400 Vp ACCURACY, -40°C to +85°C Hysteresis & Repeatability: ±0.1% of span 6-month Stability Error: ±0.2% of zero suppression Error Due to 50°C Change in Transmitter Temperature: Zero Error: ±0.2% of zero suppression Span Error: ±0.2% of span ENVIRONMENTAL Operating temperature: -40 to +85°C (-40 to +185°F) Storage Temperature: -55 to +125°C (-67 to +257°F) Relative Humidity: 0 to 100% (sealed case) Watertight Proof Pressure: 35 kPa (5 PSI) Shock: 55 g, half sine, 9-13 ms duration Vibration: 1.52 mm (0.06 in) double amplitude, 10-80 Hz cycled MECHANICAL Case Material: Zamak® zinc alloy Gasket Material: Fluorosilicone Diameter: 74 mm (2.9 in) Height, Including Barriers: 53 mm (2.1") Weight: 380 g (13 oz) Electrical Connection: #6 screws with wire clamps Terminal Protection: Standard: Screw terminal barriers plus barrier strip cover CPB1 (Optional): Plastic cover for case top (protects T/C screw terminals from air currents) NON-COMMON SPECIFICATIONS RTD INPUT - MODEL 501 Signal Source: Pt 100 RTD Span for 4-20 mA Output: 100 to 1050°C (180 to 1890°F) Zero Suppression: -200 to +750°C (-328 to +1382°F) Source Connection: 2- or 3-wire Excitation Current: 200 µA Lead Resistance, Max: 100 ohm Bandwidth: DC-60 Hz OHMS INPUT MODEL 501 Signal Source: 0-400 ohm Span for 4-20 mA Output: 35 to 400 ohm Zero Suppression: 0 to 365 ohm Source Connection: 2- or 3-wire Excitation Current: 200 µA Lead Resistance, Max: 100 ohm Bandwidth: DC-60 Hz THERMOCOUPLE INPUT MODEL 502A Span and Zero Suppression: See input table Input Resistance (Open T/C Detector Resistance): 5 M ohm Bias Current, Max: 50 nA NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 dB, 50/60 Hz, 100 mV input Thermocouple Lead Resistance: For specified performance: 100 ohm Maximum: 10 kohm Step Response, Type: 400 ms MILLIVOLT INPUT MODEL 504 Span for 4-20 mA Output: 5 to 100 mV Zero Suppression: -30 to +60 mV Input Resistance: 100 M ohm Bias Current, Max: 50 nA NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 dB, 50/60 Hz, 100 mV input Step Response, Type: 400 ms MILLIAMP INPUT MODEL 505 Span for 4-20 mA Output: 5 to 100 mA Zero Suppression: -30 to +60 mA Input Resistance: 1 ohm Step Response, Type: 400 ms VOLT INPUT MODEL 506 Span for 4-20 mA Output: 0.5 to 5 V (506-1); 5 to 50 V (506-2) Zero Suppression: -3.5 to +6.0 V (506-1); -35 to +60 V (506-2) Input Resistance: 1 M ohm Bias Current, Max: 1 nA NMV Across Input Leads: 120 Vac for 1 min NMR Across Input Leads: 40 dB, 50/60 Hz, 100 mV input Step Response, Type: 400 ms Quick Selection Guide by Input Type
*The
signal span shown in column 5 for 4-20 mA output cannot include
inputs below the maximum signal in column 4.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2003,
NEWPORT Electronics, Inc. All rights reserved.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||