AC VOLTAGE / CURRENT SIGNAL CONDITIONERS
DRX-ACC/ACV AC Voltage/Current Signal Conditioners
DIN Rail Mount

Made in Santa Ana, CA
Electromagnetic Compatibility
iDRX-ACC / ACV & iDRN-ACC / ACV
Software Selectable Input Ranges
iDRX-ACV: 0-400 mV to 0 to 400 Vac
iDRX-ACC: 0-10 mA to 0-5 A ac
14-Bit Resolution (max)
Serial I/O, A/IN, DI/O
0.2% FS Accuracy
1800 V Isolation
Free Setup and Configuration Software
Factory Setup and Configuration Available at No Charge (for iDRN Analog Output models)

NEWPORT PRODUCT INFO
MANUAL - PDF iDRN-ACC
MANUAL - PDF iDRN-ACV
MANUAL - PDF iDRX-ACC
MANUAL - PDF iDRX-ACV
• SOFTWARE iDRX ACTIVE X
SOFTWARE iDRX CONFIGURATION
SOFTWARE iDRN CONFIGURATION
SOFTWARE OPC Server
SPECS - PDF
MECHANICAL
PRICE
REQUIRES ADOBE ACROBAT - HELP

The iDRN and iDRX Series signal conditioners provide highly accurate, stable and isolated measurement of AC voltage and current signals across extremely wide ranges: AC Current ranges from 0 to 10 mA through 0 to 5 A ac; AC Voltage ranges from 0 to 400 mV to 0 to 400 Vac.

ANALOG or DIGITAL OUTPUTS
The iDRN-ACV and iDRN-ACC accept ac voltage and ac current respectively and provide an analog output which is proportional to the input. The iDRX-ACV and iDRX-ACC accept ac voltage and ac current respectively and transmit via RS-485 Serial Communications.

ANALOG OUTPUT MODEL
The Analog Output models can be configured for outputs of 0 to 10 Vdc, 4 to 20 mA or 0 to 20 mA with the free configuration software. The modules connect to a PC with RS-232 Serial Communications, or by Ethernet with the optional EIS-2B module. Once configured the settings are stored in non-volatile memory and the unit can be disconnected from the PC.

DIGITAL OUTPUT MODEL
The iDRX-ACC (Current) and iDRX-ACV (Voltage) communicate via RS-485 Serial Communications using either simple NEWPORT® ASCII Commands or the popular MODBUS Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 4,000 ft., more with RS-485 repeaters.

ETHERNET CONNECTION
The Optional EIS-2B iServer module can connect up to thirty-two (32) iDRX RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iServer can also be used as a simple Serial to Ethernet "bridge" or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet.

Factory Setup and Configuration at No Extra Charge
To make your installation even easier, your iDRN (Analog Output and RS-232) signal conditioners can be ordered preconfigured by the factory at no extra charge. You select the input types, ranges and output scale and we will program the instruments to your specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the iDRN model, please specify the “-FS” option.

Please Specify:
iDRN-ACV: Input Value High & Low
Output Value High & Low
Example: 0 volts = 4 mA, 400Vac = 20 mA
iDRN-ACC: Input Value High & Low
Output Value High & Low
Example: 0 A = 4 mA, 5 A = 20 mA

Free Active X Controls
Free Active X Controls are provided for the iDRN/iDRX series Signal Conditioners. This free software makes it easy to integrate the "iDRN/iDRX Signal Conditioners" with "Active X Containers" such as Microsoft Visual Basic as well as with popular OLE compliant data acquisition, process control, and industrial automation software from NEWPORT® as well as Wonderware, Intellution, Rockwell Automation, and Object Automation among others.


SPECIFICATIONS
Accuracy at 25°C: ±0.2% FS
Resolution: 10 to 14 bit
Power Consumption: 2.4 W; 100 mA @ 24 Vdc

Model iDRX-ACV/ iDRN-ACV
Input Ranges: 0 to 400 mV to 0 to 400 Vac full scale
Interface: RS-485; RJ-12 or screw terminal connector

Model iDRX-ACC/ iDRN-ACC
Input Ranges: 0 to 10 mA to 0 to 5 A ac full scale
iDRX Output: 2-wire (half duplex) RS-485 (
NEWPORT® ASCII Serial Protocol and MODBUS Serial Protocol)
iDRN Output: 0 to 10V @ 10 mA max; 0 to 20 mA or 4 to 20 mA

ACV Default settings iDRN: Input 0-400 VAC; Output 4-20 mA (Custom Settings available at no charge.)
ACC Default settings iDRN: Input 0-5 Amp; Output 4-20 mA (Custom Settings available at no charge.)


To Order (Specify Model No.) Prices Shown in U.S. Dollars
Model No.
Description
Price
iDRX-ACC
Digital signal conditioner with RS-485 output for ac current input
$270
iDRX-ACV
Digital signal conditioner with RS-485 output for ac voltage input
$270
iDRN-ACC
Signal conditioner with analog output for ac current inputs
$345
iDRN-ACV
Signal conditioner with analog output for ac voltage inputs
$345
-FS
Factory setup and scaling
FREE
Each unit supplied with complete operator’s manual.
Ordering Example: iDRX-ACV digital signal conditioner with RS-485 output for ac voltage inputs ($270), plus iDRN-PS-1000 power supply, 95-240 Vac input, 24 Vdc output @850mA ($150), $270 + 150 = $420.

ACCESSORIES
Model No.
Description
Price
CAT-285
Bi-directional RS-232-RS-485 converter for iDRX series
$148
DB9-RJ12
DB9 TO RJ12 Connector Adaptor includes 7 ft RJ12 Cord
$30
DB25-RJ12
DB25 TO RJ12 Connector Adaptor includes 7 ft RJ12 Cord
$30
Serial to Ethernet iServer industrial MicroServer with screw terminal serial port, servers 32 devices
$195
Switching Power supply, 95-240 Vac input, 24 Vdc output @850mA
$150
CAT-285
Bi-directional RS-232-RS-485 converter for iDRX series
$148

SOFTWARE
Model No.
Description
Price
Configuration Software for iDRN
FREE
Configuration Software for iDRX
FREE
OPC Server Software License
$295

Copyright 2007, NEWPORT Electronics, Inc. All rights reserved.
NEWPORT Newport Home Products Purchase Quotes Pricelist Manuals Site Map Search e-mail Newport Home Products Purchase Quotes Pricelist Manuals Site Map Search e-mail Newport Home