The Ultra Compact i8C/iS8C meters and controllers are similar to the full size i8 in an Ultra Compact enclosure.
Only 2 inches behind the panel.
|
|
 |
|
|

For Temp.Units
|
|
The NEWPORT® i8C is a 1/8 DIN size (96mm x 48mm) Digital Panel Meter featuring the big iSeries color-changing display. The digits are twice the size of typical 1/8 DIN panel meters.
The iSeries meters feature the only LED displays that can be programmed to change color between GREEN , AMBER, and RED at any set point or alarm point.
The “i8C” model is available as an extremely accurate programmable digital panel meter with no outputs or with dual outputs for controlling or alarming functions. The user can easily program the i8C for any control or alarming requirement from simple on-off to full autotune PID with a choice of Form C SPDT relays, Solid State Relays, DC pulse, and Analog (voltage and current) outputs.
Universal Inputs
The innovative iSeries offers the broadest selection of signal inputs available on one industrial instrument. The choices are easily selected from the Menu with four front panel pushbuttons, or by serial communications. |
|
The Universal Temperature & Process instrument (model "i") handles ten common types of thermocouples: K, J, T, E, R, S, B, C, N, and J DIN, multiple RTD's, and several Process (dc) Voltage ranges: 0-100 millivolt, 0-1 Volt, 0-10 Volt; Process Current range: 0-20 mA. This model also features built-in excitation, 24 Vdc @ 25 mA. with it's wide choice of signal inputs, this model is an excellent choice for measuring or controlling temperature with a thermocouple, RTD, or 4-20mA transmitter.
The Strain & Process instrument (model "iS") measures inputs from Load Cells, Pressure Transducers, and most any strain gauge sensor as well as several Process (dc) Voltage ranges: 0 to 100 mVdc, -100 mVdc to 1Vdc and 0 to 10 Vdc; Process Current range: 0-20 mA. The "iS" has built-in excitation of 5 Vdc @ 40mA or 10 Vdc @ 60mA for bridge transducers. This "iS" model supports 4 and 6 wire bridge configurations, ratiometric and non-ratiometric measurements. The "iS" features fast and easy "in-process" calibration/scaling of the signal inputs to any engineering units. This model also features 10 Point Linearization which allows the user to linearize the signal input from extremely nonlinear transducers of all kinds.
The MIL Standard Nickel RTD with MIL-T-7990B curve is available as a Factory Setup.
Ordering Example: iS8C33-C24-FS (FS: preset for MIL-T-7990B curve, please specify range and accuracy).
Analog Output
The optional analog output can be programmed within a range of 0-10 Vdc or 0-20 mA. It is selectable as either a control output or as a calibrated retransmission of the process value-a unique feature among controllers.
Built-in Excitation Standard
Any excitation voltage between 5 and 24 Vdc is available by special order. Built-in excitation is not available with optional -C24 isolated RS-232/ RS-485 serial communications, -C4EI Ethernet option or -DC option.
Control Functions
The iSeries can control simple manual operation to ON-OFF and full Autotune PID control. (Selectable preset tune, adaptive tune, PID, PI, PD control modes.) The dual control outputs can be configured for a variety of independent control and alarm applications such as heat/heat, heat/cool, heat/alarm, cool/cool, cool/alarm or alarm/alarm. The ramp-to-setpoint feature allows the user to define the rate of rise to setpoint, minimizing thermal shock to the load during start-up. Maximum ramp time: 99.59 (HH.MM), Soak: 00.00 to 99.59 (HH.MM), Damping: 1 to 8 in unit steps.
For applications that do not require PID control, iSeries controllers are available in two special models that offer simplified programming. The iSeries “Limit Alarm” model (specify –AL option) is a conventional limit alarm. The iSeries “Simplified Menu” model (specify –SM option) offers simplified programming. The menu flowchart is similar to programmable digital panel meters that are used for on/off control or alarms. (Please see the iSeries operator’s manuals for programming details.)
iSeries FAMILY
The NEWPORT®
iSeries
is a family of microprocessor-based instruments offered in
three DIN sizes. All
of the instruments share the same set-up and configuration
menu and method of operation, a tremendous time saver for
integration of a large system.
The
iSeries
displays feature
unique 9-segment LED characters which greatly improves alphanumeric
representations. The 7-segment LED characters found on most
instruments are adequate for presenting numbers, but not
letters. Words are easier to read with the unique 9-segment
LED characters on the iSeries,
which makes operating and programming simpler and easier.
Programmable Color Display
The
NEWPORT®
iSeries are the first
complete series of 1/8, 1/16 and 1/32 DIN process control
instruments with totally programmable color displays. The
display can be programmed to change color at any set point
or alarm point.
|
|
iSeries
Change Color at any Setpoint
|
For example, the instrument can be programmed to display the
process value in GREEN
during warm-up, switching to AMBER
to signal the normal operating range, and in RED
to signal an alarm condition. The
changes in color are quickly seen from a distance, and machine
operators can intuitively react to changing conditions. The
colors can be programmed to change back when the value drops
back below the alarm point or to "latch" on until being reset
by the operator.
The instrument can also be programmed to display only one
unchanging color: GREEN,
AMBER,
or RED.
This is a useful way to let an operator identify, at a glance,
process values in three separate locations, or to display
three different measurements such as Temperature, Pressure,
and Flow.
Designed
and Manufactured in the USA
The innovative NEWPORT®
iSeries
of meters/controllers features an extended Five (5) YEAR warranty
at no extra charge. The iSeries
packs a wealth of power and features into the smallest of
packages, utilizing COB (chip-on-board) and SMT (surface mount
technology) assembly techniques and automation. Every iSeries
instrument is thoroughly calibrated and tested at several
stages throughout production. The iSeries
offers the highest accuracy for industrial instrumentation
at 0.03% of reading. The analog-to-digital conversion utilizes
proprietary 20-bit ASIC (application specific integrated circuit)
patented algorithms and smart filtering.
Free Software
Free
software is provided for easy set-up, configuration and data
acquisition with the NEWPORT®
iSeries.
Free
ActiveX Controls
Free ActiveX Controls are provided for the iSeries,
making it easy to integrate the iSeries
with information systems using "ActiveX Containers" such as
Microsoft Visual Basic and Microsoft Excel as well as with
popular OLE and OPC compliant data acquisition, process control,
and industrial automation software from NEWPORT®,
GE Fanuc, Intellution, Rockwell Automation, Object Automation,
iconics, and Wonderware among others.
Optional
Isolated RS-232 and RS-485 Serial Communications
The iSeries
are the first intelligent
industrial
instruments to offer both RS-232 and RS-485
serial communications in one instrument which can be selected
from the menu.
The iSeries features
both the iSeries
serial protocol and MODBUS serial protocol.
The iServer is a DIN rail mounted device which can be a hub connecting up to 32 instruments to the Ethernet and Internet. The “iServer” is both a Web Server and an Ethernet-Serial bridge. To connect to the iServer, iSeries devices must feature the "-C24" Serial Communications option.
Factory Setup and Configuration
Make installing your iSeries
meter or controller easier by ordering it preconfigured by
the factory. You specify the input types,
scaling if applicable, set points, alarm points, etc. and
we will program the instruments to your specific requirements
in our calibration lab prior to shipment. For a checklist
of factory setup parameters, please consult your NEWPORT® applications engineers. The Factory Setup "-FS" and configuration
option requires the serial communication "-C24" option.
Custom
Configurations
Custom color bezels and enclosures are available for Original
Equipment Manufacturers. Enhance the appearance of your equipment
design with custom colors. Consult the NEWPORT®