Serial to Ethernet and Internet |
$195 |
|
| Features |
 |
Connects industrial serial devices with RS-232,
RS-485, or RS-422 to an Ethernet network and
the Internet |
 |
Replaces dedicated wiring and PC’s for serial
connections |
 |
Digital
input/output lines |
 |
Well-developed
TCP/IP Stack |
 |
Web based interface for easy configuration and
access without any special software |
 |
Configuration
option via Telnet and Serial |
 |
Supports TCP, UDP, ARP, Telnet, DHCP, DNS, HTTP,
and MODBUS protocols |
 |
Includes
a Windows based COM port redirection software
to redirect data destined for a serial COM port
to the Ethernet port on a PC |
 |
Includes
a Windows based software utility to access and
configure the iServer over the Network |
 |
Password
protection for Security |
 |
Snaps
easily into DIN Rail mounting rack |
 |
Firmware
upgradeable |
 |
Custom
firmware and private labeling for OEM's |
 |
OEM
board-level iServer available |
|
|
|
The award-winning NEWPORT®
i®Server
is the simplest, easiest, most economical way to connect
serial devices to an Ethernet network and the Internet.
When you type its name in a Web Browser, it serves
Web pages that let you quickly and easily configure
the device for your specific application
without any special software. |
|
Getting started with the iServer
is very simple and easy because it can take a dynamically
assigned IP address from a DHCP server on your network.
This DHCP client capability is a valuable and unique feature
of the NEWPORT iServer
that makes it extremely easy and simple to start using this
device on almost any Ethernet network.
You can easily assign a static IP address to the iServer
instead of a dynamic one, if necessary. The IP address can
be assigned locally through its serial connection, as well
as remotely over an Ethernet network via Telnet or a web
browser, using its factory default IP address.
The NEWPORT iServer
connects to an Ethernet Network with a standard RJ45 connector.
Serial devices connect to screw terminals on removable connectors.
You can select RS-232, or RS-485 (and RS-422) Serial Communications
from the configuration Web page
The iServer can be used
to make an existing Serial device a "node" on an Ethernet
network with a unique IP address that's accessible from
any authorized computer on the LAN, WAN, or Internet. The
iServer can instead
be used to create a virtual tunnel on an Ethernet/Internet
network simulating a local point-to-point serial connection
between a serial device and a PC.
This replaces dedicated point-to-point wiring limited to
50 feet on an RS-232 connection. The NEWPORT iServer
packages the Serial data in standard TCP/IP packets that
can travel anywhere on the Ethernet LAN or over the Internet.
The NEWPORT iServer
is compatible with almost any device with a Serial interface
such as: time clocks, security alarms, card-key access controllers,
telecommunications equipment, vending machines, bar code
readers, electric power meters, UPS systems, test & measurement
instrumentation, PLC's, serial printers, cash registers,
and many more.
You do not need to rewrite the firmware for your serial
devices to work with the iServer,
and in some cases might not need to change your application
software. Your serial devices will function over the Ethernet
network or the Internet as if they were connected directly
to a PC. The COM port on the iServer
simulates a local COM port on the PC.
The NEWPORT iServer
is compatible with wireless Ethernet. In settings where
wires of any kind are not possible, the EIS-2B can
be connected to a Wireless Ethernet Access Point enabling
simple, economical wireless connectivity of Serial Devices.
With the NEWPORT iServer:
A manufacturing manager can monitor PLC's over the LAN from
a desk anywhere in the facility, or from anywhere on the
Internet with the proper passwords and authorization. A
technician can use a handheld computer with Wireless Ethernet
connectivity to change settings on a process controller.
The NEWPORT iServer
model EIS-2B comes complete with full documentation,
and firmware.
For OEM's, NEWPORT offers custom labeling as well as customized
application specific firmware and design engineering. NEWPORT
also offers printed circuit board-level products model EIS-PCB (powered
by 5 Vdc) that OEM's can incorporate in their product to
add embedded Ethernet/Internet connectivity to products
with existing serial interface. (Contact the NEWPORT OEM
Engineering Group.)
For IT and commercial applications, NEWPORT offers other
iServer Device Servers
in steel enclosures for rack mounting. The EIS-W
models feature a DB-9 connector and come complete with a
110 or 240 Vac power adapter.
NEWPORT iServer products
are designed and manufactured in Santa Ana, California.
NEWPORT provides generous technical support.
Specifications
Serial
Interface
Interface: Software selectable RS-232, RS-422 or RS-485
(2 wire)
Connector: screw terminal plugs, 8 position
Data Rates: 300 to 115.2 Kbps
Characters: 7 or 8 data bits
Parity: odd, even, or none
Stop Bits: 1 or 2
Flow Control: Hardware (RTS/CTS) and Software (Xon/Xoff).
Digital I/O’s: 4 digital input/output lines
Network Interface
Interface: Ethernet 10Base-T
Connector: RJ45
Protocols:
TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS, HTTP, Telnet,
and MODBUS/TCP
Indicators
(LED's)
Network Activity, Network Link, and Serial Transmit/Receive
Processor
CPU:
Enhanced 8051, 22 MHz
Memory:
512
Kbyte Flash, 16 Kbyte SRAM
Management
Embedded Web server, Telnet login, Serial login
Embedded Web Server
Serves dynamic Web pages and Java applets (256 Kbyte
capacity)
Power Input - DIN Rail Enclosure
(DC Power Supply sold separately iDRN-PS-1000)
Input: 10-32 Vdc
Consumption: 2 W max.
Environmental
Operating Temperature: 0 to 70°C (32 to 158°F)
Storage Temperature: -40 to 125°C (-40 to 257°F)
Packaging - DIN Rail Enclosure
Material: Polycarbonate case with DIN Rail mount
Dimensions: 90.2H x 25.1W x 115.0D mm (3.54 x .99
x 4.53 in)
Weight: 113 g (0.25 lbs.)
Agency Approvals
Software
Firmware upgradeable (for iServer firmware
upgrade package, (EIS-FW-CA and EIS-FW-CD)
contact NEWPORT oem@newportUS.com
or 714-540-4914)
COM Port redirector (iPORT)
Configuration Software utility (iCONNECT)
Compatible with Windows 9x/ME/NT/2000/XP software and
related utilities
Ordering Information
MicroServer™:
serial interface (RS-232, RS-422, RS-485), 10Base-T/Ethernet,
diagnostic LEDs, DIN Rail mountable, CD-ROM with documentation,
and printed Quick Start Guide
EIS-2B
shown with iDRX Signal Conditioners
and PS-1000 Power Supply
|
|
Embedded
Web Server Screen Shots



Mechanical Dimensions
To
Order
(*Specify Model No.)
Prices shown in U.S. Dollars
Model # |
Description |
Price* |
EIS-2B |
iServer Industrial MicroServer™ with screw terminal serial port |
$195 |
|
Accessories
|
|
|
RAIL-35-2
|
6.5ft (2m) section of 35 mm DIN rail |
$15
|
|
|
Power
Supply (switching), 95 to 240 Vac input, 24
Vdc output @ 850mA (power up to 7 units) |
$150
|
|

iDRN-PS-1000
|