The innovative NEWPORT® iSeries devices feature state of the art technology, uncompromising accuracy, and quality backed by an extended 5-year warranty. The iSeries family includes extremely accurate digital panel meters and single loop PID controllers that are simple to configure and use, while providing tremendous versatility and a wealth of powerful features. Embedded Internet and Serial Communications Featuring optional "Embedded Internet" (specify -EI option) the iSeries are the first instruments of their kind that connect directly to an Ethernet network and transmit data in standard TCP/IP packets, or even serve Web pages over a LAN or the Internet. The iSeries are also available with serial communications. With the -C24 option, the user can select from the push-button menu between RS-232, RS-422, and RS-485, with straightforward ASCII commands or MODBUS.
Programmable Color Display The NEWPORT iSeries are the first complete series of 1/8, 1/16 and 1/32 DIN process control instruments with totally programmable color displays. The display can be programmed to change color at any set point or alarm point.
For example, the instrument can be programmed to display the process
value in GREEN
during warm-up, switching to AMBER
to signal the normal operating range, and in RED
to signal an alarm condition. The changes in color are quickly seen
from a distance, and machine operators can intuitively react to changing
conditions. The colors can be programmed to change back when the value
drops back below the alarm point or to "latch" on until being reset
by the operator.
The instrument can also be programmed to display only one unchanging color: GREEN, AMBER, or RED. This is a useful way to let an operator identify, at a glance, process values in three separate locations, or to display three different measurements such as Temperature, Pressure, and Flow. QUALITY and TECHNOLOGY Designed and manufactured in the USA, the innovative NEWPORT® iSeries of meters & controllers features an extended five (5) YEAR warranty at no extra charge. The iSeries packs a wealth of power and features into the smallest of packages, utilizing COB (chip-on-board) and SMT (surface mount technology) assembly techniques and automation. Every iSeries instrument is thoroughly calibrated and tested at several stages throughout production. The iSeries offers the highest accuracy for industrial instrumentation at 0.03% of reading. The analog-to-digital conversion utilizes a proprietary 20-bit ASIC (application specific integrated circuit) patented algorithms and smart filtering.
The innovative iSeries offers the broadest selection of signal inputs available on one industrial instrument. The choices are easily selected from the menu with four front panel pushbuttons, or by serial or ethernet communications. 10 Thermocouple Types The iSeries handles TEN (10) thermocouple types: K, J, T, E, R, S, B, C, N, and J DIN. The patented thermocouple linearization algorithms employed in the iSeries produce the highest standard of accuracy. Most Accurate RTD Measurements The iSeries works with the widest selection of RTD's and produces the most accurate RTD measurements. Handles 100 (ohm), 500 (ohm) and 1000 (ohm) Platinum RTDs with 385 and 392 linearization. A choice of 2-, 3- and 4-wire RTD connections ensures the absolute highest degree of accuracy. Process Voltage and Current The iSeries measures process voltage: 0-100 millivolt, 0-1 Volt, 0-10 Volt ranges, and process current: 0-20 mA or 4-20 mA.
Strain Gauge The Strain/Process meters and controllers (model "iS") measure inputs from Load Cells, Pressure Transducers, and most any strain gauge sensor. Input ranges include 0 to 100 mVdc, -100 mVdc to 1Vdc and 0 to 10 Vdc in addition to 0-20mA. Built-in excitation bridge transducers, 5Vdc @ 40 mA or 10 Vdc @ 60mA. When communications options are installed, external excitation may be used and ratiometric operation maintained by connecting the external excitation to the sense leads. Both 4 or 6-wire bridge configurations are supported for internal or external excitation. Non-ratiometric operation is also supported for voltage and current transducers. Non-ratiometric operation is also valuable in measuring offset and millivolt output of bridge devices during manufacturing and calibration. Strain/Process meters and controllers are available in all iSeries Models. MIL Standard Nickel RTD Special option for Nickel RTD MIL-T-7990B curve is available as a Factory Setup. Analog Output The optional analog output can be programmed within a range of 0-10 Vdc or 0-20 mA. It is selectable as either a control output or as a calibrated retransmission of the process value - a unique feature among controllers. Control Functions The iSeries can control simple manual operation to ON-OFF and full Autotune PID control. (Selectable preset tune, adaptive tune, PID, PI, PD control modes.) The dual control outputs can be configured for a variety of independent control and alarm applications such as heat/heat, heat/cool, heat/alarm, cool/cool, cool/alarm or alarm/alarm. The ramp-to-setpoint feature allows the user to define the rate of rise to setpoint, minimizing thermal shock to the load during start-up. Maximum ramp time: 99.59 (HH.MM), Soak: 00.00 to 99.59 (HH.MM), Damping: 1 to 8 in unit steps. For applications that do not require PID control, iSeries controllers are available in two special models that offer simplified programming. The iSeries “Limit Alarm” model (specify –AL option) is a conventional limit alarm. The iSeries “Simplified Menu” model (specify –SM option) offers simplified programming. The menu flowchart is similar to programmable digital panel meters that are used for on/off control or alarms. (Please see the iSeries operator’s manuals for programming details.) Built-in Excitation Standard The Temperature/Process (model “i”) comes standard with built-in excitation (24 Vdc @ 25 mA). This means the same instrument can handle thermocouple, standard RTD’s, or 4-20mA transmitters, with the meter’s built-in excitation. The Strain/Process (model “iS”) comes standard with built-in excitation (10Vdc @ 60mA), 5V excitation is user selectable. Any excitation voltage between 5 and 24 Vdc is available by special order. Built-in excitation is not available with optional isolated RS-232/ RS-485 serial communications, -C4EI Ethernet option or -DC option.
Specifications:
Universal Temperature & Process Input (Model "i") Accuracy: ±0.5°C temp; 0.03% reading process Resolution: 1°/0.1°; 10 µV process Temperature Stability: 1) RTD: 0.04°C/°C 2) TC: @25°C (77°F): 0.05 °C/°C - Cold Junction Compensation 3) Process: 50 ppm/°C Input Types: Thermocouple, RTD, Analog Voltage, Analog Current Thermocouple Lead Resistance: 100 ohm max Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L RTD Input (ITS 68): 100/500/1000 ohm Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve Voltage Input: 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc Input Impedance: 10 Mohm for 100 mV, 1 Mohm for 1 or 10 Vdc Current Input: 0 to 20 mA (5 ohm load) Excitation (optional in place of Communication): 24 Vdc @ 25 mA (Not Available for Low Power Option) Decimal Selection: None, 0.1 for temperature; None, 0.1, 0.01 or 0.001 for process Universal Strain & Process Input (Model "iS") Accuracy: 0.03% reading Resolution: 10/1µV Temperature Stability: 50 ppm/°C NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples per second Digital Filter: Programmable Input Types: Analog Voltage, Analog Current Voltage Input: 0 to 100 mVdc, -100 mVdc to 1 Vdc, 0 to 10 Vdc Input Impedance: 10 Mohm for 100 mV; 1 Mohm for 1 V or 10 Vdc Current Input: 0 to 20 mA (5 ohm load) Excitation (optional in place of Communication): 5 Vdc @ 40 mA; 10 Vdc @ 60 mA. Linearization Points: Up to 10 Linearization Points Decimal Selection: None, 0.1, 0.01 or 0.001 Common Specs (Model "i" and "iS") NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples per second Digital Filter: Programmable Display: 4-digit, 9-segment LED • 10.2 mm (0.40"): i32, i16, i16D (Dual Display), i8DV (Dual Vertical) • 21 mm (0.83"): i8 • 10.2 mm (0.40") and 21 mm (0.83"): i8DH (Dual Horizontal) Red, green and amber programmable colors for process variable, set point and temperature units Configuration: Single-ended Polarity: Unipolar Step Response: 0.7 sec for 99.9% Setpoint Adjustment: -1999 to 9999 counts Span Adjustment: 0.001 to 9999 counts Offset Adjustment: -1999 to +9999 Control Action: Reverse (heat) or direct (cool) Modes: Time and Amplitude Proportional Control Modes; selectable Manual or Auto PID, Proportional, Proportional with Integral, Proportional with Derivative with Anti-reset Windup and ON/OFF Rate: 0 to 399.9 seconds Reset: 0 to 3999 seconds Cycle Time: 1 to 199 seconds; set to 0 for ON/OFF operation Gain: 0.5 to 100% of span; Setpoints 1 or 2 Damping: 0000 to 0008 Soak: 00.00 to 99.59 (HH:MM), or OFF Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF Auto Tune: Operator initiated from front panel Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3 A (Resistive Load); configurable for on/off, PID and Ramp and Soak Output 1: SPDT type, can be configured as Alarm 1 output Output 2: SPDT type, can be configured as Alarm 2 output SSR: 20-265 Vac @ 0.05 - 0.5 A (Resistive Load); continuous DC Pulse: Non-Isolated; 10 Vdc @ 20 mA Analog Output (Output 1 only): Non-Isolated, Proportional 0 to 10 Vdc or 0 to 20 mA; 500 ohm max Network and Communications (Options -C24, -C4EI, -EI)) Ethernet: Standards Compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS-232/RS-422/RS-485/MODBUS: selectable from menu; both ASCII and modbus protocol selectable from menu. Programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS-485: Addressable from 0 to 199 Connection: Screw terminals Alarm 1 & 2 (programmable) Type: Same as Output 1 & 2 Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations Analog Output (programmable): Non-Isolated, Retransmission 0 to 10 Vdc or 0 to 20 mA, 500 ohm max (Output 1 only). Accuracy is ±1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analog Output is not scaled below 3% of Output FS. Insulation Power to Input/Output: 2300 Vac per 1 minute test For Low Voltage/Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Outputs: 2300 Vac per 1 minute test Relay/SSR to Relay/SSR Outputs: 2300 Vac per 1 minute test RS-232/485 to Inputs/Outputs: 500 Vac per 1 minute test Approvals: UL, C-UL, CE per EN61010-1:2001, FM for Temperature units only General Line Voltage/Power: 90-240 Vac ±10%, 50-400 Hz*, 110-375 Vdc, equivalent voltage Low Voltage/Power Option: 24 Vac**, 12-36 Vdc: i8, i16, i32; 20-36 Vdc: i8DH, i8DV, i16D from qualified safety approved source Environmental Conditions: 0-55°C (32-131°F) 90% RH non-condensing: for all models i8, i16, i32. 0 to 50°C (32 to 122°F), 90% RH non-condensing: for i8DV, i8DH, i16D to comply with UL Protection: NEMA-4 (IP65) front bezel * No CE compliance above 60 Hz ** Can be safely powered but no certification for UL/CE are claimed. Dimensions i/8 Series: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5") i/16 Series: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5") i/32 Series: 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5") Panel Cutout i/8 Series: 45 H x 92 mm W (1.772" x 3.622"), 1/8 DIN i/16 Series: 45 mm (1.772") square, 1/16 DIN i/32 Series: 22.5 H x 45 mm W (0.886" x 1.772"), 1/32 DIN Weight i/8 Series: 295 g (0.65 lb) i/16 Series: 159 g (0.35 lb) i/32 Series: 127 g (0.28 lb)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2005,
NEWPORT Electronics, Inc. All rights reserved.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||