View Barometric Pressure, Temperature + Humidity
with a Web Browser
Adjustable Charts
Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). Barometric Pressure can be displayed in hectopascals (hPa), millimeters of Mercury (mmHg), or inches of Mercury (inHg).
Adjustable Chart
|

Reading Sensor Web Page
|
Display and Chart Measurements
The iBTHX transmitters come complete with a barometric pressure, temperature and humidity probe for measurement of a single location. NEWPORT offers a choice of industrial probes in 5" lengths and a wand style for ambient indoor applications.
|
|
Optional Caps available for Wand style and 5" Industrial Probes.
|
Award-winning Technology
The NEWPORT iBTHX is simple to install and use, and features NEWPORT's award-winning iServer technology that requires no special software except a Web Browser. The iBTHX connects to an Ethernet Network with a standard RJ45 connector and sends data in standard TCP/IP packets. It is easily configured with a simple menu using a Web Browser and can be password protected. From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name such as "Cleanroom 5" or "Midwest Server Room" in any Web Browser, and the iBTHX serves a Web Page with the current readings.
Typical Applications
The NEWPORT iBTHX is great for monitoring temperature + humidity in applications such as: clean rooms, computer rooms, HVAC systems, pharmaceutical and food processing and storage, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, greenhouses, farm animal shelters, and many more.
|
NEW iBTX-M with Flash Memory and LCD Display
The NEWPORT model iBTX-M with LCD display, adds several valuable features in addition to the backlit local display of temperature and humidity. The "MEMORY" model comes complete with a removable 2-MEGABYTE Flash Memory card that can store one full year of readings taken at one-minute intervals (or two months of readings taken at ten second intervals).
Up to four years of temperature + humidity readings can be stored on the 8 Mbyte card. With data being recorded in the built-in nonvolatile flash memory, a failure on the Ethernet network will not interrupt the data record. |
|
Alarm Relays
The NEWPORT iBTX-M features two 1.5 Amp relays. With the easy Web-based setup page, the two relays can be programmed for any combination of temperature or pressure, and high or low set points. The relays can also be programmed to remain latched and require a manual reset if a limit is exceeded.
Email Alarms
In addition to the mechanical alarm relays, all NEWPORT iBTHX models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user or a distribution list anywhere in the world, including an Internet enabled pager or cell phone.
Battery Backup
The iBTX-M comes with a universal ac adapter. A standard 9 Volt Alkaline battery (also included) allows the device to log data for up to 10 days without external ac power. In locations without power or network accessibility, the iBTX-M continues logging data to its flash memory. The stored data can later be downloaded over the Ethernet.
NEWPORT iServer products are designed and manufactured in Santa Ana, California.
Specifications
|
Sensor Specifications
Barometric Pressure (B)
Accuracy/Range:
±2.0 mbar / 0-1100 mbar (0-110 KPa)
Resolution: 0.1 mbar
Relative Humidity (H)
Accuracy/Range: ±2% for 10 to 90%
±3% for 0 to 10% and 90 to 100%
Non-linearity: ±3%
Hysteresis: ±1% RH
Response Time: 4 sec.
(63% slowly moving air)
Repeatability: ±0.1%
Resolution: 0.03%, 12 bit
|
Temperature (T)
Accuracy/Range*:
Wand Probe:
±0.8°C @ 20°C (±1.5°F @ 68°F)
±1°C for 0°C to 70°C (±2°F for 32°F to 158°F)
Industrial Probe:
±0.8°C @ 20°C (±1.5°F @ 68°F)
±1°C for -40 to 110°C (±2°F for -40 to 230°F)
±2°C for 110 to 125°C (±3.6°F for 230 to 257°F)
*Note: extended temperature range is for Industrial Probe only, the iServer's operating temp. is 0-70 °C.
Response Time: 5 sec. (63% slowly moving air)
Repeatability: ±0.1°C
Resolution: 0.01°C, 14 bit
|
Probe Specifications
Wand Probe:
159 mm long x 19 mm diameter 6.25" x 0.75")
Cable with DB9 connector: 152 mm long (6")
Cable operating temp: 0 to 80°C (32 to 176°F)
|
Industrial Probe:
137mm long x 16mm diameter (5" x 0.63")
Housing material: SS316
Cable with DB9 connector: 3m long (10’)
Cable operating temp: 0 to 105°C (32 to 221°F)
|
iServer Specifications
Interfaces
Ethernet: 10Base-T (RJ45)
Supported Protocols
TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
Indicators (LED's)
Network Activity, Network Link, Transmit and Receive/Diagnostics
LCD Display
16 Digits 6mm (0.23") for iBTX-M
Memory
512 Kbytes Flash, 16 Kbytes SRAM
Memory Data Flash Card
2 M bytes: 2 months of data storage at 10 seconds logging intervals
or 1 year at 1 minute intervals for iBTX-M
Relay Outputs
Two Relays 1.5A @ 30 Vdc for iBTX-M
Management
Device configuration and monitoring through embedded WEB server (Figure 1)
Embedded WEB Server
Serves WEB pages containing real-time data (Figure 2)
and live updated charts within definable time intervals (Figure 3).
Environmental
Operating Temperature: 0 to 70°C
(32 to 158°F)
Storage Temperature: -40 to 125°C
(-40 to 257°F)
Power |
Input: 9 to 12 Vdc iBTHX-W, iBTX-W, iBTX-M
Consumption: 2.5 W max.
Safety Qualified ac Power Adapter (included)
Nominal Output: 9 Vdc @ 0.5 A
Input: 100 to 240 Vac, 50/60 Hz
Power Adapter Operating Temperature:
0º to 40ºC (32º to 104ºF)
Battery: 9Vdc, Alkaline for iBTX-M

Universal ac Power Adapter included
with iBTHX-W, iBTX-W and iBTX-M
|
Input: 10 to 32 Vdc iBTHX-D, iBTX-D
Switching Power Supply:
iDRN-PS-1000 sold separately
Consumption: 2.5 W max.

iDRN-PS-1000 $150 for iBTHX-D, iBTX-D
|
| Packaging
|
Material - iiBTHX-W, iBTX-W, iBTX-M:
Metal case with flange mount
Dimensions:
21H x 62W x 90D mm
(0.83 x 2.42 x 3.56 in) iBTHX-W, iBTX-W
37H x 62W x 90D mm
(1.44 x 2.42 x 3.56 in) iBTX-M
Weight: 180 g (0.4 lbs.) iBTHX-W, iBTX-W
298 g (0.8 lbs.) iBTX-M
|
Material - iBTHX-D, iBTX-D:
Polycarbonate case with DIN Rail mount
Dimensions: iBTHX-D, iBTX-D
90.2H x 25.1W x 115.0D mm
(3.54 x 0.99 x 4.53 in)
Weight: 113 g (0.25 lbs.) |
Agency Approvals
|
Calibration
 |
Software
Firmware upgradeable (for iServer firmware upgrade package, (iBTHX-FW-CD) contact Newport oem@newportUS.com or 714-540-4914)
Configuration Software utility (iCONNECT)
Including an Excel program for automatic data logging within definable time intervals (Fig. 4 and Fig. 5), compatible with all Windows (9x/ME/NT/2000/XP) operating systems.
|
To Order (*Specify Model No.) Prices shown in U.S. dollars
Model # |
Description |
Price* |
iBTX-W |
|
iServer MicroServer™ for Barometric Pressure and Temperature, includes universal (100 to 240 Vac) power adapter. |
$295 |
iBTHX-W |
|
iServer MicroServer™ for Barometric Pressure, Temperature, Humidity and Dewpoint, includes universal (100-240 Vac) power adapter. |
$395 |
iBTX-M |
|
iServer MicroServer™ for Barometric Pressure and Temperature with LCD Display, includes 2Mbyte Flash Memory Card, 2 Relay Alarm, Battery Back-up, and universal (100 to 240 Vac) power adapter. |
$395 |
| |
* |
Standard Wand Probe, cable 6" (152mm) with DB9 Connector. (No entry required) |
N/C |
| |
-5 |
Industrial 5" (137mm) Probe, cable 10 ft (3m) with DB9 Connector. Substitution for Wand Probe. |
$25 |
Accessories |
|
iBTP-W-6 |
Wand Probe, cable 6" (152mm) with DB9 Connector. Barometric Pressure/Temp. |
$100 |
iBTHP-W-6 |
Wand Probe, cable 6" (152mm) with DB9 Connector. Barometric Pressure/Temp/Humidity |
$170 |
iBTP-5-DB9 |
Industrial 5" (137mm) Probe, cable 10 ft (3m) with DB9 Connector. Barometric Pressure/Temperature |
$125 |
iBTHP-5-DB9 |
Industrial 5" (137mm) Probe, cable 10 ft (3m) with DB9 Connector. Barometric Pressure/Temperature/Humidity |
$195 |
DB9-CA-3 |
Extension Cable, 3 ft (0.9m) with DB9 Connector |
$15 |
iBT-MC2 |
Memory Data Flash Card, 2M byte / 1 Year @ 1 Minute Intervals (iBTX-M) |
$10 |
iBT-MC4 |
Memory Data Flash Card, 4M byte / 2 Years @ 1 Minute Intervals (iBTX-M) |
$20 |
iBT-MC8 |
Memory Data Flash Card, 8M byte / 4 Years @ 1 Minute Intervals (iBTX-M) |
$30 |
|
Polyethylene Probe Cap, for wet environments |
N/C |
|
Porous Stainless Steel Probe Cap, 5um porosity, for dusty and pressurized (< 35 psi) environments |
$25 |
|
Replacement universal ac power adapter |
$25 |
|
Refer to the ordering guides below |
- |
Ordering Example for iBTHX-W-5 iServer Microserver with Industrial 5" Barometric Pressure, Temperature and Humidity Probe and 10' cable: $395 + 25 = $420
|
Model # |
Description |
Price* |
iBTX-D |
DIN Rail iServer Industrial MicroServer™ for Barometric Pressure and Temperature with Industrial 5" (137mm) Probe, cable 10 ft (3m) with Stripped Wire Leads. |
$295 |
iBTHX-D |
DIN Rail iServer Industrial MicroServer™ for Barometric Pressure, Temp, RH and Dewpoint with Industrial 5" (137mm) Probe, cable 10 ft (3m) with Stripped Wire Leads. |
$395 |
Accessories |
|
iBTP-5 |
Industrial Probe 5" (137mm), cable 10 ft (3m) with Stripped Wire Leads. Barometric Pressure/Temperature. |
$125 |
iBTHP-5 |
Industrial Probe 5" (137mm), cable 10 ft (3m) with Stripped Wire Leads. Barometric Pressure/Temperature/Humidity |
$195 |
|
DIN Rail Power Supply (switching), 95 to 240 Vac input, 24 Vdc output @ 850mA (powers up to 7 units) |
$150 |
|
Polyethylene Probe Cap, for wet environments |
N/C |
|
Porous Stainless Steel Probe Cap, 5um porosity, for dusty and pressurized (< 35 psi) environments |
$25 |
RAIL-35-2 |
6.5 ft (2 m) section of 35 mm DIN rail |
$15 |
|
Refer to the ordering guides below |
- |
Ordering Example iBTX-D for DIN Rail iServer Microserver with Industrial 5" Barometric Pressure and Temperature Probe and 10' cable, plus Power Supply iDRN-PS-1000. $295 + 150 = $445.
* Volume discounts are available.
For Temperature + Humidity Controller and Monitor Panel Meters, refer to the iTH iSeries
Calibrated Replacement Probes, including Calibration Certificate |
iBTP-W-6 |
|
Wand Probe, cable 6" (152mm) with DB9 Connector |
$100 |
iBTHP-W-6 |
|
Wand Probe, cable 6" (152mm) with DB9 Connector |
$170 |
iBTP-5-DB9 |
|
Industrial 5" (137mm) Probe, cable 10 ft (3m) with DB9 Connector |
$125 |
iBTHP-5-DB9 |
|
Industrial 5" (137mm) Probe, cable 10 ft (3m) with DB9 Connector |
$195 |
iBTP-5 |
|
Industrial 5" (137mm) Probe, cable 10 ft (3m) with Stripped Wire Leads |
$125 |
iBTHP-5 |
|
Industrial 5" (137mm) Probe, cable 10 ft (3m) with Stripped Wire Leads |
$195 |
|
|
NIST Traceable Calibration Certificate. Three (3) Humidity Points of 25%, 50%, 75%, one temperature 25°C. |
$50 |
|
-CAL-3-HU-P-T |
NIST Traceable Calibration Certificate. Three (3) Humidity, Barometric Pressure and Temperature Points. |
$100 |
|
-CAL-3-P |
NIST Traceable Calibration Certificate. Three (3) Barometric Pressure Points, Temperature 25°C. |
$50 |
Ordering Example for a calibrated, replacement wand style probe: iBTHP-W-6-CAL-3-HU. $170 + 50 = $220
Calibration for New Units |
|
NIST Traceable Calibration Certificate. Three (3) Humidity Points of 25%, 50%, 75%, one temperature 25°C. |
$125 |
CAL-3-HU-P-T |
NIST Traceable Calibration Certificate. Three (3) Humidity, Barometric Pressure and Temperature Points. |
$250 |
CAL-3-P |
NIST Traceable Calibration Certificate. Three (3) Barometric Pressure Points, Temperature 25°C. |
$125 |
|
Calibration Kit, 33% and 75% RH Standards. |
$75 |