Models 2003B
and 2004 are high-accuracy AC voltmeters or true-RMS voltmeters.
Exceptional noise rejection is provided by a conversion circuit with
a crystal oscillator, which is set for either 50 or 50 Hz rejection.
Both models are available for voltage or current input and allow special
scaling for the output of a 5 A current transformer (CT). A screw-terminal
barrier strip for power and signal is standard.
All AVG models use a precision op-amp rectifier circuit to provide an
economical, high-resolution AC voltmeter, which is calibrated to display
the true-RMS value of sinusoidal signals. All RMS models use an integrated
circuit that computes the true-root-mean-square value of complex input
signals. Screw terminals are provided for AC or DC coupling. AC coupling
allows the measurement of the AC component or ripple from a signal with
both AC and DC components. DC coupling allows the measurement of true-RMS,
including AC and DC components, from DC to over 30 kHz. Maximum crest
factor (Vp/Vrms) is 3:1).
BCD Output Standard
Non-isolated parallel BCD output is a standard feature and is implemented
on the main circuit board. Additional data and control outputs can be
provided by an optional upper board.
Options
The meter main assembly can be electrically configured for four voltage
or five current input ranges. Upper-board options include four BCD output
boards. Mechanical options include connectors and splash-proof lens
cover which meets NEMA-4 standards.
LA1
(Ultra-Low) 2004
Load-Cell Conditioner Upper Board
LP1 (Ultra-Low) 2004
Load-Cell
Peak-Hold Upper Board
OPTION
F3A
Non-Isolated Parallel BCD Upper Board, Three-State with
1-Bit Enable
OPTION F3P
Peak/Valley Detector Upper Board with BCD Output
OPTION F4A
Isolated Parallel BCD Upper Board, Three-State with 1-Bit
Enable
OPTION F4M
Isolated, Parallel BCD Upper Board Three-State with 4-Bit
Address
OPTION 05 - 204B
Analog-Output Upper Board
OPTION 06 - 204B/2004
Digital-Setpoint Upper Board
OPTION SPC4
1/8
DIN NEMA-4 Splash-Proof Lens Cover
SPECIFICATIONS
ACCURACY FOR AVG at 25°C
Maximum error, 35 Hz to 2 kHz: ±0.1% of reading ±20 counts
Maximum error, 20 Hz to 5 kHz: ±0.3% of reading ±20 counts
Span tempco: ±0.015% of reading/°C
Step response: 1 s
Warmup to rated accuracy: 1 hour
ACCURACY FOR RMS at 25°C (1% to 100% of full-scale)
Maximum error, AC coupling
35 Hz to 5 kHz: ±0.1% of reading ±10 counts
25 Hz to 10 kHz: ±0.2% of reading ±20 counts
23 Hz to 15 kHz: ±0.25% of reading ±30 counts
20 Hz to 20 kHz: ±0.5% of reading ±50 counts
20 Hz to 30 kHz: ±1.0% of reading ±50 counts
Maximum error, DC coupling
DC error: ±0.1% of reading ±10 counts
AC error: Same as for AC coupling
Span tempco: ±0.02% of reading/°C
Step response: 1 s
Warmup to rated accuracy: 1 hour
Maximum crest factor at full scale (Vp/Vrms): 3:1
POWER
AC voltages: 115 Vac ±10% at 60 Hz; 230 Vac ±10% at 50 Hz
Power consumption: 4.5 W (nominal)
ENVIRONMENTAL
Operating temperature: 0 to 50°C (32 to 140°F)
Storage temperature: -40 to +75°C (-40 to 184°F)
Relative humidity: 95% at 40°C (104°F) (non-condensing)
MECHANICAL
Dimensions: Newport (1/8 DIN) case
Weight: 17 oz (480 g)
Case material: 94V-0 UL-rated polycarbonate
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Model
|
| |
Select 2003B for AC VOLTMETER 2004 for TRUE RMS METER
|
(2)
|
INPUT SIGNAL
|
| |
Select -AVG for AC voltage (includes D4) -RMS for True RMS voltage (includes D4) -LA1 for Gain-programmable preamplifier with active filter and bridge excitation supply -LP1 for Gain-programmable preamplifier with peak-hold and bridge-excitation supply - DC Input Signals -2 for ± 199.99 mVdc -3 for ± 1.9999 Vdc -4 for ± 19.999 Vdc -5 for ± 199.99 Vdc
|
(3)
|
For AVG or RMS INPUT SIGNAL (Not applicable for LA1, LP1 or FS Input Signals)
|
| |
Select Nothing(leave field blank) for not applicable ,VR2 for 199.99 mVac or rms ,VR3 for 1.9999 Vac or rms ,VR4 for 19.999 Vac or rms ,VR5 for 199.99 Vac or rms ,CR2 for 199.99 µA ac or rms ,CR3 for 1.9999 mAac or rms ,CR4 for 19.999 mAac or rms ,CR5 for 199.99 mAac or rms ,CR6 for 1.9999 A ac or rms ,CR7 for Current transformer (CT) scaling for 5 A ac or rms
|
(4)
|
TEMPERATURE COEFFICIENT
|
| |
Select Nothing(leave field blank) for Standard (±0.006% of reading/°C) ,LT for High-stability (±0.002% of reading/°C) (mutually exclusive with options AVG, RMS, LA1, LP1)
|
(5)
|
READ-RATE OPTION
|
| |
Select Nothing(leave field blank) for Standard (4.3/s at 60 Hz, 3.6/s at 50 Hz) ,FR for 10 measurements/sec at 60 Hz power only (mutually exclusive with options AVG, RMS, LA1, LP1, F3P)
|
(6)
|
3-WIRE RATIO DC INPUT IMPEDANCE
|
| |
Select Nothing(leave field blank) for Standard ,HZ for High impedance (1 G ohm reference input only).
|
(7)
|
UPPER-BOARD OUTPUT OPTIONS - Mutually exclusive with LA1, LP1, F3P, F80A and FR
|
| |
Select Nothing(leave field blank) for None (unbuffered, non-isolated BCD is standard)* ,F3A for Buffered, gated and stored BCD output* ,F3P for Stored peak or valley BCD output* ,F4A for Buffered, isolated, gated and stored BCD output* ,F4M for F4A with 4-line binary addressing* ,06 for Single-setpoint controller with TTL and 1A relay outputs (requires option D4)*
|
(8)
|
POWER
|
| |
Select Nothing(leave field blank) for 120 Vac (optimized for 60 Hz rejection) ,C1 for 240 Vac (optimized for 50 Hz rejection) ,C3 for 5 Vdc (optimized for 60 Hz rejection** ,C4 for 5 Vdc (optimized for 50 Hz rejection)**
|
(9)
|
ADD-ON OPTIONS
|
| |
Select Nothing(leave field blank) for no option ,D4 for Screw-terminal barrier strip for power and signal Removes power and signal from D1
|
(10)
|
ADD-ON OPTIONS
|
| |
Select Nothing(leave field blank) for no option ,BL for Lens without Newport logo
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | | | | |
|
 |
 |
|
|
|
|
Back to top |
|
|