Navigation image map
Contact Us Cart Site Map Manuals Quotes Products Home

3 3/4 DIGIT STRAIN METERS WITH BCD OUTPUT
MODEL 204B-LA2 & 204B-LP2
OPTION AVG/RMS
      
Electromagnetic Compatibility

NEWPORT PRODUCT INFO
• MANUAL - PDF Version
• MECHANICAL 1/8 DIN (1A) Case
• MECHANICAL NEMA-SIZE Case (optional)
• MECHANICAL Connections Diagram
• PRICE
• REQUIRES ADOBE ACROBAT - HELP
STANDARD FEATURES
­480 to +3,999-count display span
True-differential preamplifier
Isolated 5, 10, 15 Vdc excitation supply
2 Hz low-pass active filter, LA2 version
Peak-hold with external reset, LP2 version
1500 Vp CMV, 120 dB CMR
Parallel BCD output
1 mV/count analog output
Bright, 0.56 in (14.2 mm) LED display
115/230 Vac power
1/8 DIN case
   
OPTIONS
Dummy right-hand zero
NEMA-4 splash-proof lens cover

Models 204B-LA2 and 204B-LP2 are high-quality 3 3/4 digit panel meters for use with pressure transducers, load cells and other bridge transducers which require excitation and preamplification of microvolt signals.

Model 204B-LA2 provides a 2 Hz two-pole active filter for superior normal mode noise rejection (NMR) of 90 dB.

Model 204B-LP2 provides an analog peak-hold circuit with external reset. It is useful for destructive testing applications.

BUILT-IN EXCITATION SUPPLY AND PREAMP
The 204B-LA2 and 204-LP2 provide an isolated, constant-voltage excitation supply, which can be field-configured for 5, 10 or 15 V dc output. They also provide a high-impedance, true-differential preamplifier, which is continuously adjustable from 20 to 800 in 3% steps to accommodate load-cell sensitivities of 1 mV/V to 20 mV/V. Fine-gain and fine-deadload adjustments are easily accessible behind the lens. A push-to-cal switch is provided through the lens. The calibration shunt resistor is customer supplied.

BRIDGE CONNECTION
Bridges can be connected by 4 or 6 wires. In 6-wire connection, two lines sense the voltage applied to the bridge and compensate for lead resistance.

DISPLAY RESOLUTION AND ACCURACY
Display resolution is one part in 3999 counts, or 0.025% of full scale. Accuracy is up to 99.95%. of reading. The measurement is ratiometric to reduce errors due to temperature and power-line variations. The same internal reference controls the meter gain and the excitation level.

SIGNAL OUTPUTS
Standard outputs include non-isolated parallel BCD and a strip-chart recorder output of 1 mV/count (nominal).

OPTIONS
Options are an extra fixed right-hand zero for more flexibility in scaling to engineering units; a splash-proof lens cover, which meets NEMA-4 requirements; and board-edge connectors for the DPM lower board and the LA2 or LP2 signal conditioner upper board. For additional information, please refer to the Options and Mechanical sections.
Load Cells
OMEGADYNE™ Load Cells
available from
NEWPORT®
CLICK HERE FOR SELECTION GUIDE

SPECIFICATIONS
ANALOG INPUT
Most-sensitive scaling
Least-sensitive scaling
Signal Range
­0.6 to +5 mV
­20 to +200 mV
Display Range
­480 to +3999
­480 to +3999
Resolution
1.25 µV/count
50 µV/count
Preamplifier Gain
800
20

Input configuration: Differential, ratiometric
Coarse-span adjustment: 125 overlapping ranges with fine adjustment
Fine-span adjustment: ±3% of span
Zero adjustment: ±3% of bridge output
Deadload adjustment, max: Up to 60% of bridge output with external resistor
Tare adjustment: ±12 counts nominal
Bias current: 11 nA typ, 22 nA max

NOISE REJECTION
NMR, SIG HI to SIG LO, LA2 option: 90 dB, 50/60 Hz
NMR, SIG HI to SIG LO, LP2 option: 60 dB, 50/60 Hz
CMR, SIG GND to SIG LO: 80 dB, DC to 60 Hz
CMR, SIG GND to PWR GND: 120 dB, 50/60 Hz
CMV, SIG GND to PWR GND: 1500 Vp test, 354 Vp per IEC spacing

ACCURACY AT 25°C
Error, max:
±0.02% of reading ±1 count
Zero tempco, max: ±0.3 µV/°C
Span tempco: ±0.005% of reading/°C
Step response: 1 s to 99.9% of span
Warmup to rated accuracy: 60 min

CONVERSION
Technique: Dual-slope, average-value
Signal integration period: 50 ms at 60 Hz, 40 ms at 50 Hz
Read rate: 2.5/s

EXCITATION
Configuration: Constant-voltage
Voltage sense: Internal or remote
Voltage settings: Jumper-selectable 5, 10, 15 Vdc
Load current, max: 125 mA at 5 V, 115 mA at 10 V, 67 mA at 15 V

DISPLAY
Type: 7-segment, red LED
Height: 0.56 in (14.2 mm)
Symbols: ­8.8.8.8
Decimal points: Three positions programmable internally or at connector
Overrange indication: Display flashes

DIGITAL SIGNALS
Output signals: TTL-compatible
HOLD input: TTL or 5 V CMOS compatible
BLANKING input: Open-collector compatible

POWER
AC voltages:
115 Vac ±10% at 60 Hz; 230 Vac ±10% at 50 Hz
Power consumption: 8 W (nominal)

ENVIRONMENTAL
Operating temperature:
0 to 50°C
Storage temperature: ­40 to +75°C
Relative humidity: 95% at 40°C (non-condensing)

MECHANICAL

Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical section for drawings)
Weight: 23 oz (650 g)
Case material: 94V-0 UL-rated polycarbonate



To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description    Qty.
 204B-LA2 in-stock    $515.00     3 3 /4 digit (± 3,999 count) panel meter with gain-programmable preamplifier with active filter and bridge excitation  
 204B-LP2 in-stock    $534.00     3 3 /4 digit (± 3,999 count) panel meter with gain-programmable preamplifier with peak hold and bridge excitation  
 
All dollar amounts on this site are shown in US currency.

 Part Number Builder
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
204B
Option Descriptions
(1) INPUT SIGNAL
  Select
-LA2 for Gain-programmable preamplifier with active filter and bridge excitation
-LP2 for Gain-programmable preamplifier with peak hold and bridge-excitation - DC Input Signals
-AVG for AC voltage (includes D4 connector)
-RMS for True-RMS voltage (includes D4 connector)
-1 for ± 39.99 mVdc
-2 for ± 399.9 mVdc
-3 for ± 3.999 Vdc
-4 for ± 39.99 Vdc
-5 for ± 399.9 Vdc
(2) AVG or RMS INPUT SIGNALS (Not applicable for LA2, LP2 or -FS Input Signals)
  Select
Nothing(leave field blank) for Not applicable
,VR1 for 39.99 mV ac or rms
,VR2 for 399.9 mV ac or rms
,VR3 for 3.999 Vac or rms
,VR4 for 39.99 Vac or rms
,VR5 for 399.9 Vac or rms
,CR1 for 39.99 µA ac or rms
,CR2 for 399.9 µA ac or rms
,CR3 for 3.999 mA ac or rms
,CR4 for 39.99 mA ac or rms
,CR5 for 399.9 mA ac or rms
,CR6 for 3.999 A ac or rms
,CR7 for Current transformer (CT) scaling for 5 A ac or rms
(3) DISPLAY RANGE OPTION
  Select
Nothing(leave field blank) for ±3,999 counts (standard)
,ER1 for ±4,999 counts (DC input signal only)
,ER2 for ±5,999 counts (DC input signal only)
(4) ZERO-OFFSET ADJUSTMENT
  Select
Nothing(leave field blank) for Standard (±0.35% of span)
,ZO for Extended (±10% of span) not available with FS
(5) OPTICAL ISOLATION
  Select
Nothing(leave field blank) for None (analog and digital grounds are tied together)
,OI for Optical isolation between analog and digital grounds. Mutually exclusive with input option LP2
(6) 3-WIRE RATIO INPUT IMPEDANCE
  Select
Nothing(leave field blank) for Standard
,HZ for High-impedance (100 Mohm reference input only)
(7) UPPER-BOARD OUTPUT OPTIONS - Mutually exclusive with options LA2 and LP2 - *Includes PCB edge connector
  Select
Nothing(leave field blank) for None (unbuffered, non-isolated BCD is standard)*
,F3A for Buffered, gated and stored parallel BCD output*
,F3P for Buffered and stored parallel BCD with peak or valley hold*
,F4A for Buffered, isolated, gated, and stored parallel BCD*
,F4M for F4A with 4-line binary addressing*
,05 for Linearized analog output of 0.5 mV/count for use with AC powered units only. D1, D3, D4 required**
,06 for Single-setpoint controller with TTL and reed-relay outputs (programmed by customer at rear connector)**
,0506 for Both 05 and 06 output options for use with AC powered units only. D4 required*
(8) POWER
  Select
Nothing(leave field blank) for 115 Vac, 50/60 Hz
,C1 for 230 Vac, 50/60 Hz
,C3 for 5 Vdc (optimized for 60 Hz rejection)
,C4 for 5 Vdc (optimized for 50 Hz rejection)
,C3B for Isolated 9-32 Vdc (optimized for 60 Hz rejection)
,C4B for Isolated 9-32 Vdc (optimized for 50 Hz rejection)
,C3D for Isolated 26-56 Vdc (optimized for 60 Hz rejection)
,C4D for Isolated 26-56 Vdc (optimized for 50 Hz rejection)
(9) ADD-ON OPTIONS
  Select
Nothing(leave field blank) for No Options
,XZ for Extra zero, fixed, at right of display
(10) ADD-ON OPTIONS
  Select
Nothing(leave field blank) for No Options
,D4 for Screw-terminal barrier strip for power and signal (removes these inputs from PCB edge connector)
(11) ADD-ON OPTIONS
  Select
Nothing(leave field blank) for No Options
,BL for Lens without Newport logo
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   

   Back to top

Sitemap | Order Status | Careers | About Us | ISO 9001 | Worldwide Affiliates | Terms & Conditions