3 1/2 DIGIT
MINI-SIZE DC VOLTMETER
MODEL 205-A / 305-A -
MODEL 205-P, -E / 305-P, -E
Model 205-A is
a low-cost 3 1/2 digit DC voltmeter with a full-size 0.56 in (14.2
mm), red or green LED display, yet housed in a small 3/64 DIN case
with a 24 x 72 mm bezel. The case fits into a standard 3/64 DIN
cutout, 0.87 x 2.68 in (22.2 x 68 mm), and requires a depth of less
than 4.72 in (120 mm) behind the panel, including plug-in screw-clamp
connectors (standard).
The 205-A offers 99.9% accuracy and jumper-selectable DC voltage
ranges of ±199.9 mV, ±1.999 V, ±19.99 V and ±199.9
V. The input is true differential, with excellent common mode rejection
(CMR).
AC- or DC-POWERED
Multiple choices are available for AC or DC power. All provide
EMI filtering, so that power line noise does not affect the meter
reading. AC power options are 24, 100, 115 or 230 V ac. Non-isolated
DC power options are 5 or 7-32 V dc.
DESIGNED FOR
SAFETY
Many
design features are incorporated to ensure compliance with the latest
worldwide safety specifications. To minimize the possibility of
electrical shock, there are no openings which would allow electrical
contact with a probe 0.16 in (4 mm) in diameter. Proper creepage
distances are observed for power and signal as specified by IEC-348,
Class 1. The power transformer uses separate bobbins for the primary
and secondary windings. Type-Y AC line filter capacitors and removable
screw-clamp connectors comply with VDE and UL specifications. Noryl
SE-1 plastic is used in the case for mechanical strength and flame
retardance.
SPECIFICATIONS
ANALOG
INPUT
|
Range
|
±199.9
mV
|
±1.999
V
|
±19.99
V
|
±199.9
V
|
|
Resolution
|
100
µV
|
1
mV
|
10
mV
|
100
mV
|
|
Maximum
Input
|
130
Vp
|
250
Vp
|
250
Vp
|
250
Vp
|
|
Input
Resistance
|
1
Gohm
|
1.1
Mohm
|
1.0
Mohm
|
1.0
Mohm
|
|
Bias
Current
|
50
pA
|
5
pA
|
1
pA
|
1
pA
|
Configuration: Differential, Bipolar
Zero: Automatic
Span Adjustment: ±5%
NOISE REJECTION
NMR:
56 dB, 50/60 Hz
CMR, SIG LO to PWR GND: 120 dB, DC to 60 Hz
CMV, SIG LO to PWR GND: 1500 Vp per HV test, 354 Vp
per IEC spacing
CMV, SIG LO to DIG GND: 0 V
ACCURACY AT 25°C
Maximum
error: ±0.05% of reading ±1 count
Span tempco: ±0.01% of reading/°C
Step response: 1 s
Warmup to rated accuracy: 30 min
ANALOG-TO-DIGITAL CONVERSION
Technique: Dual-slope, average-value
Polarity: Automatic
Signal integration period: 100 ms
Read rate: 2.5/sec
DISPLAY
Type: 7-segment, red LED
Color: Red or green
Height: 0.56 in (14.2 mm)
Symbols: 1.8.8.8
Decimal points: Three position jumper-selectable
behind lens
Overrange indication: Three least-significant digits blank
POWER OPTIONS
AC voltage: 24, 100, 115, 230 V ac ±15%
AC frequency: 49-63 Hz
DC voltage (non-isolated): 5 V dc ±5%, 7-32 V dc
Power consumption, AC or DC: 1.5 W
ENVIRONMENTAL
Operating temperature: 0 to 60°C
Storage temperature: 40 to 85°C
Relative humidity: 95% at 40°C (non-condensing)
MECHANICAL
Dimensions: Newport DIN2472-100 (3/64 DIN) (see Mechanical
section for drawings)
Bezel (standard): 0.94 x 2.83 in (24 x 72 mm)
Bezel (with TP2 adapter): 0.98 x 2.96 in (25 x 75 mm)
Panel cutout: 0.87 x 2.68 in (22.2 x 68 mm)
Depth behind bezel (with connector): 4.72 in (120 mm)
Weight: 7 oz (200 g)
Case material: 94V-1 UL-rated Noryl SE-1
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
DC VOLTAGE INPUT
|
| |
Select -AV2 for ±199.9 mV -AV3 for ±1.999 V -AV4 for ±19.99 V -AV5 for ±199.9 V - PROCESS SIGNAL INPUT -PA1 for 4-20 mA -PV2 for 0-1999.9 mV -PV3 for 1-5 V -PV4 for 0-10 V -PV5 for 0-100 V - PROCESS SIGNAL INPUT WITH EXCITATION OUTPUT -EA1 for 4-20 mA -EV2 for 0-199.9 mV -EV3 for 1-5 V -EV4 for 0-10 V -EV5 for 0-100 V - THERMOCOUPLE INPUT - Type J, Iron-Constantan (Fe-CuNi) -JC1 for -210 to +760°C -JC2 for -199.9 to +199.9°C -JF1 for -346 to +1400°F -JF2 for -199.9 to +199.9°F - Type K, Chromel-Alumel (NiCr-NiAl) -KC1 for -105 to +1372°C -KC2 for -199.9 to +199.9°C -KF1 for -157 to +1999°F -KF2 for 199.9 to +199.9°F - Type T, Copper-Constantan(Cu-CuNi) -TC1 for -105 to +400°C -TC2 for -199.9 to +199.9°C -TF1 for -157 to +752°F -TF2 for -199.9 to +199.9°F - Type E, Chromel-Constantan (NiCr-CuNi) -EC1 for -105 to +1000°C -EC2 for -199.9 to +199.9°C -EF1 for -157 to +1832°F -EF2 for -199.9 to +199.9°F - RTD (Pt 100) INPUT, Alpha of 0.00385, calibrated to IEC 751 (IPTS-68) -MC1 for -200 to +850°C -MF1 for -328 to +1562°F- -MC1 for -199.9 to +199.9°C -MF2 for -199.9 to +199.9°F
|
(2)
|
DISPLAY COLOR
|
| |
Select ,R for Standard red LED ,G for Green LED
|
(3)
|
POWER
|
| |
Select ,C0 for 115 Vac, 49/63 Hz ,C1 for 230 Vac, 49/63 Hz ,C2 for 7-32 Vdc, non-isolated (for -A & -P) ,C2A for 9-26 Vdc, non-isolated (for temperature versions). Use ungrounded Thermocouples to avoid ground loops ,C3 for 5 Vdc, non-isolated (not compatible with -E or temperature versions) ,C5 for 100 Vac, 50/60 Hz ,C8 for 24 Vac, 50/60 Hz
|
(4)
|
ADD-ON OPTIONS
|
| |
Select Nothing(leave field blank) for No Options ,BL for Lens without Newport logo in lieu of standard lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | |
|
 |
 |
|
|
|
|
Back to top |
|
|