3 1/2 DIGIT MINI-SIZE DC VOLTMETER
MODEL 205-A / 305-A - MODEL 205-P, -E / 305-P, -E

205-A
Made in Santa Ana, CA
Electromagnetic Compatibility


NEWPORT PRODUCT INFO
MANUAL 205-A
MANUAL 305-A
MECHANICAL 3/64 DIN Case (205)
MECHANICAL 1/8 DIN Case (305)
MECHANICAL Connections Diagram
PRICE
REQUIRES ADOBE ACROBAT - HELP
STANDARD FEATURES
Miniature DIN case with 24 x 72 mm bezel
Full-size, 0.56 in (14.2 mm) LED display
±1,999-count display span
True-differential input
3-wire ratio input
120 dB CMR, 56 dB NMR
EMI/RFI power filter
Removable screw-clamp cable connector
Automatic zero and polarity
Display hold
   
OPTIONS
±200 mV to ±200 V dc ranges
Red or green LED display
24, 100, 115 or 230 V ac power
Non-isolated 5 or 7-32 V dc power
25 x 75 mm bezel adapter

Model 205-A
is a low-cost 3 1/2 digit DC voltmeter with a full-size 0.56 in (14.2 mm), red or green LED display, yet housed in a small 3/64 DIN case with a 24 x 72 mm bezel. The case fits into a standard 3/64 DIN cutout, 0.87 x 2.68 in (22.2 x 68 mm), and requires a depth of less than 4.72 in (120 mm) behind the panel, including plug-in screw-clamp connectors (standard).

The 205-A offers 99.9% accuracy and jumper-selectable DC voltage ranges of ±199.9 mV, ±1.999 V, ±19.99 V and ±199.9 V. The input is true differential, with excellent common mode rejection (CMR).

AC- or DC-POWERED
Multiple choices are available for AC or DC power. All provide EMI filtering, so that power line noise does not affect the meter reading. AC power options are 24, 100, 115 or 230 V ac. Non-isolated DC power options are 5 or 7-32 V dc.


DESIGNED FOR SAFETY
Many design features are incorporated to ensure compliance with the latest worldwide safety specifications. To minimize the possibility of electrical shock, there are no openings which would allow electrical contact with a probe 0.16 in (4 mm) in diameter. Proper creepage distances are observed for power and signal as specified by IEC-348, Class 1. The power transformer uses separate bobbins for the primary and secondary windings. Type-Y AC line filter capacitors and removable screw-clamp connectors comply with VDE and UL specifications. Noryl SE-1 plastic is used in the case for mechanical strength and flame retardance.

SPECIFICATIONS

ANALOG INPUT
Range
±199.9 mV
±1.999 V
±19.99 V
±199.9 V
Resolution
100 µV
1 mV
10 mV
100 mV
Maximum Input
130 Vp
250 Vp
250 Vp
250 Vp
Input Resistance
1 Gohm
1.1 Mohm
1.0 Mohm
1.0 Mohm
Bias Current
50 pA
5 pA
1 pA
1 pA

Configuration: Differential, Bipolar
Zero: Automatic
Span Adjustment: ±5%

NOISE REJECTION
NMR:
56 dB, 50/60 Hz
CMR, SIG LO to PWR GND: 120 dB, DC to 60 Hz
CMV, SIG LO to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing
CMV, SIG LO to DIG GND: 0 V


ACCURACY AT 25°C

Maximum error: ±0.05% of reading ±1 count
Span tempco: ±0.01% of reading/°C
Step response: 1 s
Warmup to rated accuracy: 30 min

ANALOG-TO-DIGITAL CONVERSION
Technique: Dual-slope, average-value
Polarity: Automatic
Signal integration period:
100 ms
Read rate: 2.5/sec

DISPLAY
Type: 7-segment, red LED
Color: Red or green
Height: 0.56 in (14.2 mm)
Symbols: ­1.8.8.8
Decimal points: Three position jumper-selectable behind lens
Overrange indication: Three least-significant digits blank

POWER OPTIONS
AC voltage:
24, 100, 115, 230 V ac ±15%
AC frequency: 49-63 Hz
DC voltage (non-isolated): 5 V dc ±5%, 7-32 V dc
Power consumption, AC or DC: 1.5 W

ENVIRONMENTAL
Operating temperature:
0 to 60°C
Storage temperature: ­40 to 85°C
Relative humidity: 95% at 40°C (non-condensing)

MECHANICAL
Dimensions: Newport DIN2472-100 (3/64 DIN) (see Mechanical section for drawings)
Bezel (standard): 0.94 x 2.83 in (24 x 72 mm)
Bezel (with TP2 adapter): 0.98 x 2.96 in (25 x 75 mm)
Panel cutout: 0.87 x 2.68 in (22.2 x 68 mm)
Depth behind bezel (with connector): 4.72 in (120 mm)
Weight: 7 oz (200 g)
Case material: 94V-1 UL-rated Noryl SE-1



To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description    Qty.
 205-AV2,G,C0 in-stock    $145.00     3 1/2 digit (±1,999 count) digital indicator, ±199.9 mV input range, green LED, 115 Vac power  
 205-AV3,G,C0 in-stock    $145.00     3 1/2 digit (±1,999 count) digital indicator, ±1.999 V input range, green LED, 115 Vac power  
 Accessories
 TP2 in-stock    $30.00     25 x 75 mm bezel adapter (25 x 68 mm panel cutout)  
 TP3 in-stock    $30.00     Bezel adapter for 3/64 DIN to 1/8 DIN  
 RP23 in-stock    $50.00     19" Rack panel for 2 3/64 DIN meters  
 RP43 in-stock    $55.00     19" Rack panel for 4 3/64 DIN meters  
 
All dollar amounts on this site are shown in US currency.

 Part Number Builder
(1) (2) (3) (4)
205
Option Descriptions
(1) DC VOLTAGE INPUT
  Select
-AV2 for ±199.9 mV
-AV3 for ±1.999 V
-AV4 for ±19.99 V
-AV5 for ±199.9 V - PROCESS SIGNAL INPUT
-PA1 for 4-20 mA
-PV2 for 0-1999.9 mV
-PV3 for 1-5 V
-PV4 for 0-10 V
-PV5 for 0-100 V - PROCESS SIGNAL INPUT WITH EXCITATION OUTPUT
-EA1 for 4-20 mA
-EV2 for 0-199.9 mV
-EV3 for 1-5 V
-EV4 for 0-10 V
-EV5 for 0-100 V - THERMOCOUPLE INPUT - Type J, Iron-Constantan (Fe-CuNi)
-JC1 for -210 to +760°C
-JC2 for -199.9 to +199.9°C
-JF1 for -346 to +1400°F
-JF2 for -199.9 to +199.9°F - Type K, Chromel-Alumel (NiCr-NiAl)
-KC1 for -105 to +1372°C
-KC2 for -199.9 to +199.9°C
-KF1 for -157 to +1999°F
-KF2 for 199.9 to +199.9°F - Type T, Copper-Constantan(Cu-CuNi)
-TC1 for -105 to +400°C
-TC2 for -199.9 to +199.9°C
-TF1 for -157 to +752°F
-TF2 for -199.9 to +199.9°F - Type E, Chromel-Constantan (NiCr-CuNi)
-EC1 for -105 to +1000°C
-EC2 for -199.9 to +199.9°C
-EF1 for -157 to +1832°F
-EF2 for -199.9 to +199.9°F - RTD (Pt 100) INPUT, Alpha of 0.00385, calibrated to IEC 751 (IPTS-68)
-MC1 for -200 to +850°C
-MF1 for -328 to +1562°F-
-MC1 for -199.9 to +199.9°C
-MF2 for -199.9 to +199.9°F
(2) DISPLAY COLOR
  Select
,R for Standard red LED
,G for Green LED
(3) POWER
  Select
,C0 for 115 Vac, 49/63 Hz
,C1 for 230 Vac, 49/63 Hz
,C2 for 7-32 Vdc, non-isolated (for -A & -P)
,C2A for 9-26 Vdc, non-isolated (for temperature versions). Use ungrounded Thermocouples to avoid ground loops
,C3 for 5 Vdc, non-isolated (not compatible with -E or temperature versions)
,C5 for 100 Vac, 50/60 Hz
,C8 for 24 Vac, 50/60 Hz
(4) ADD-ON OPTIONS
  Select
Nothing(leave field blank) for No Options
,BL for Lens without Newport logo in lieu of standard lens
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   

   Back to top

Sitemap | Order Status | Careers | About Us | ISO 9001 | Worldwide Affiliates
Copyright ©2008, NEWPORT Electronics, Inc. All rights reserved.