THERMOCOUPLE SIGNAL CONDITIONER / TRANSMITTERS
|
The
iDRN-TC and iDRX-TC signal conditioners provide
highly accurate, stable, isolated measurement of thermocouple
sensors. Thermocouple types are selected and the outputs are scaled
with the free configuration software, or can be done at the factory
for no additional charge. The T/C Signal Conditioners can accept
9 different thermocouple types: J, K, T, E, R, S, B, N, and J
DIN.
TWO MODELS: ANALOG or DIGITAL OUTPUTS
iDRN-TC provides an analog output that is proportional to
the input signal. The iDRX-TC uses a digital RS-485 communication
link.
ANALOG OUTPUT MODEL
The output of iDRN-TC can be user set for 0 to 10 V, 4
to 20 mA or 0 to 20 mA. Input scaling and configuration of other
operating parameters is accomplished by connecting to a standard
RS-232 port of a personal computer and using the free Windows-based
setup software. Once configured the settings may be stored in
non-volatile memory and the unit disconnected from the PC.
DIGITAL OUTPUT MODEL
The iDRX-TC is a digital signal conditioner which communicates
over an RS-485 communication link using either a simple, straightforward
NEWPORT® ASCII Serial Protocol or MODBUS
Serial Protocol. Up to 32 modules may be connected to a single
RS-485 port stretching up to 4,000 ft. without repeaters.
ETHERNET CONNECTION
The Optional EIT-D iServer module can connect up to thirty-two
(32) iDRX RS-485 Signal Conditioners to an Ethernet network
and the Internet using standard TCP/IP protocol. The iServer can
also be used as a simple Serial to Ethernet "bridge" or converter
to connect a single iDRN RS-232 device to an Ethernet network
and the Internet.
Factory Setup and Configuration at No Extra Charge
To make your installation even easier, your iDRN (Analog
Output and RS 232) signal conditioners can be ordered preconfigured
by the factory at no extra charge. You select the input types,
ranges and output scale and we will program the instruments to
your specific requirements in our calibration lab prior to shipment.
For custom factory setup and scaling of the iDRN model,
please specify the “-FS” option.
Please Specify:
Thermocouple Type
Temperature High & Low
Output Value High & Low
Example: Type J, 0°C = 4mA, 100°C = 20mA
Free Active X Controls
Free Active X Controls are provided for the iDRN/iDRX series Signal
Conditioners. This free software makes it easy to integrate the
"iDRN/iDRX Signal Conditioners" with "Active X Containers" such
as Microsoft Visual Basic as well as with popular OLE compliant
data acquisition, process control, and industrial automation software
from NEWPORT® as well as Wonderware, Intellution,
Rockwell Automation, and Object Automation among others.
SPECIFICATIONS
Accuracy at 25°C: ±1°C
Resolution: 0.1°C
Power Consumption: 2.4 W (100 mA @ 24 Vdc)
Input Types: J, K, T, E, R, S, B, N, J DIN
Input Ranges: See range chart
iDRX Output: 2-wire (half duplex) RS-485 (NEWPORT®
ASCII
Serial Protocol and MODBUS Serial Protocol)
iDRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to
20 mA, 10 V compliance
Thermocouple
Default settings iDRN: Input Type K, Range 0-1000°F; Output
4-20 mA (Custom Settings available at no charge.)
|
Input
|
Range,
°F
|
Range,
°C
|
|
Input
|
Range,
°F
|
Range,
°C
|
|
J
|
-346
to 1400°F
|
-210 to 760°C
|
|
R
S
|
-58
to 3214°F
|
-50
to 1768°C
|
|
K
|
-454 to 2500°F
|
-270 to 1372°C
|
|
B
|
+212
to 3300°F
|
+100
to 1820°C
|
|
T
|
-454 to 752°F
|
-270 to 400°C
|
|
N
|
-454 to 2372°F
|
-270 to 1300°C
|
|
E
|
-454 to 1832°F
|
-270 to 1000°C
|
|
J
DIN
|
-328 to 1652°F
|
-200 to 900°C
|
 |
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Output Signal
|
| |
Select N for ANALOG OUTPUT X for DIGITAL RS485 OUTPUT
|
(2)
|
Input Signal
|
| |
Select PR for PROCESS VOLTAGE OR CURRENT ST for STRAIN GAGE/BRIDGE OR MILLIVOLT TC for THERMOCOUPLE INPUT RTD for RTD INPUT ACV for AC VOLTAGE INPUT ACC for AC CURRENT INPUT FP for FREQUENCY/PULSE INPUT
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
|
|
 |
 |
|
|
|
|
Keywords:THERMOCOUPLE SIGNAL CONDITIONER / TRANSMITTERS
|
Back to top |
|
| |