PADDLEWHEEL
FLOW SENSOR SYSTEM
|
The
INFCTRA Series panel meter supplies power for the
flow sensor and provides rate indication, or totalization,
and batch control (when ordered with the dual relay option).
When ordered with the analog output option, the INFCTRA
can be used to interface the FP7000 flow signal to such
items as strip chart recorders, dataloggers, and computer
interfaces.
The system consists of the flow sensor, an installing
fitting, and electronics. The PVC tee fittings are supplied
with a PVC locking nut, and the galvanized iron tee fittings
are supplied with a brass locking nut to provide a secure
metal-to-metal mounting to the threaded brass insert. |
 |
The FP7000 is not compatible with FP-5300 or FMG-5300 Series installation
fittings. When powered by the FPW-5 five Vdc wall socket converter,
the FP7000 has a TTL level pulse output which can be used with
a variety of pulse input flow indicators, signal conditioners
and controllers. It is not compatible with the FPM 730/740.

INFCTRA Series
compatible indicators, for flowrate, or total or batch control,
sold separately. |

Available with
PVC or galvanized iron fittings |
SPECIFICATIONS
Accuracy: ±2% of full scale
Repeatability: ±1% of full scale
Power: 5 to 18 Vdc @ 10 mA maximum
Wetted Materials
FP7000 Series sensor
polypropylene body (PVDF), PVDF paddle, FKM
O-ring, 316SS shaft. Galvanized iron tee
includes brass insert and locking nut. PVC tee has PVC insert
and locking nut.
Fluid Temperature/Pressure Range
Do not exceed the maximum ratings of your piping. Depending on
the material of the fitting, the operating Temperature/ pressure
may be limited by your piping, and not by the sensor. For all
PVC tee fittings, do not exceed 150 PSIG @ 27ºC (80ºF),
100 PSIG @ 38ºC (100ºF), 60 PSIG @ 49ºC (120ºF),
30 PSIG @ 60ºC (140ºF), due to the insert in the tee.
FP7000 sensor
0-26ºC (32 to 80ºF) up to 150 PSIG; max. pressure decreases
1.1 PSIG per each 0.56ºC ( 1ºF) above 27ºC (80ºF) for a max. temperature
of 93ºC ( 200ºF) at 18 PSIG max.
Frequency Output:
Nominal 1 Hz/fps. amplitude of open collector pulse = Vdc input
power
Cable Length: 2.4 m (8 feet)
Weight
FP7001: 0.2 kg (1/2 lb)
FP7030GI: 2.8 kg (6 1/4 lb)
FP7030: 4.3 kg (9 1/2 lb)
Max Viscosity: 5 cps
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: All PVC fittings include some straight pipe
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
MODEL & INSTALLATION FITTINGS
|
| |
Select 001 for PADDLEWHEEL FLOW SENSOR SYSTEM 007 for PVC Tee Schedule 40 - 3/4 in. pipe, flowrange (gpm) 2.0 to 30 010 for 1 in. pipe, flowrange (gpm) 3.0 to 50 012 for 1 1/4 in. pipe, flowrange (gpm) 5.0 to 90 015 for 1 1/2 in. pipe, flowrange (gpm) 7.0 to 125 020 for 2 in. pipe, flowrange (gpm) 11 to 205 025 for 2 1/2 in. pipe, flowrange (gpm) 15 to 285 030 for 3 in. pipe, flowrange (gpm) 25 to 460 007-GI for GALVANIZED IRON - 3/4 in. pipe, flowrange (gpm) 2.0 to 30 010-GI for 1 in. pipe, flowrange (gpm) 3.0 to 50 012-GI for 1 1/4 in. pipe, flowrange (gpm) 5.0 to 90 015-GI for 1 1/2 in. pipe, flowrange (gpm) 7.0 to 125 020-GI for 2 in. pipe, flowrange (gpm) 11 to 205 025-GI for 2 1/2 in. pipe, flowrange (gpm) 15 to 285 030-GI for 3 in. pipe, flowrange (gpm) 25 to 460
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
|
 |
 |
|
|
|
|
Back to top |
|
|