True-RMS Scalable Indicator
INFCAC
- Discontinued -


True-RMS Scalable Indicator
4-Digit, 14-Segment LED Display, Red or Green
High 0.1% of Reading Accuracy
Wide Selection of ac Current and Voltage Ranges
Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Pending)
Front Panel Configuration
Available with Dual 5 Amp Relays and/or Analog Output
Peak and Valley Detection and Memory
Optional RS-485 Communications






The INFCAC series has been discontinued. Please see the DP20 series, or consult sales to inquire about remaining inventory or get advice on possible alternatives.

INFCAC
true RMS meters are the leader in advanced AC monitoring and control. There are two models, an ac Voltmeter and an ac Ammeter. Four full digits plus broad scaling capabilities allow the meter to be used in most industrial and research applications. Easy plug-in rear panel connectors make installation and removal quick and easy. Optional user scalable analog output either 4-20 mA or 0-10 V allows either a control or recorder interface and the optional dual 5 A relays gives you extended control capability. The optional plug-in communication options can be added at any time allowing the instrument to grow with your application. Front panel range changes or via the serial communications option allows flexibility not often found in a meter in this price range. Security is provided by an internal hardware lockout.

Peak and Valley
The INFCAC meter provides the ability to capture and display both peak and valley levels of your input signals. This is particularly important for such applications as destructive testing, pressure testing, etc.

SPECIFICATIONS
Max. Error, ac Coupling: ±(0.1% rdg ± 10 counts) at 50 or 60 Hz. ±(0.1% rdg ± 40 counts) from 40 Hz to 3 kHz
Max. Error, dc Coupling: ±(0.1% rdg ± 10 counts) at 50 or 60 Hz. ± (0.1% rdg ± 30 counts) from 40 Hz to 3 kHz
Span Temperature Coefficient: 0.01%/°C typical
Step Response: 2-3 seconds to 99% of final value
Warmup to Rated Accuracy: 30min.

ENVIRONMENTAL
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Relative Humidity: 90% at 40°C (104°F) (non-condensing)

POWER
AC Voltage: 115 or 230 Vac ±10%; 49-100 Hz
Consumption: 3 to 10 watts max.

NOISE REJECTION
CMR: 100 dB typical at DC
CMV: 1500 V peak per Hv test

CONFIGURATION
Offset & Span Adjustments: +0.001 to +9999 or -0.01 to -199, programmable

CONVERSION
Technique: dual slope
Read Rate: 2.5/sec

MECHANICAL
Dimensions: 48 H x 96 W x 156 mm D (1.89" x 3.78" x 6")
Panel Cutout: 45 H x 92 mm W (1.772" x 3.622")
Weight: 574 g (20 oz.)

INPUT TYPES AND RANGE
AC Voltage: (user selectable) 0-100 mV, 0-1 V, 0-10 V, 0-100 V, 0-750 V
AC Current: (user selectable) 0-1 mA, 0-10 mA, 0-100 mA, 0-1 A, 0-5 A

INFCAC-( * )
( * )
( * )
( * )
( * )
POWER AND LED COLOR
0
- - - - 115 Vac power and red LED
1
- - - - 230 Vac power and red LED
2
- - - - 115 Vac power and green LED
3
- - - - 230 Vac power and green LED
- - - - - CONTROL OUTPUT
-
0
- - - No control output
-
1
- - - Two 5 A form "C" SPDT relays
- - - - - ANALOG OUTPUT
- -
0
- - No Output
- -
1
- - 4 to 20 mA or 0 to 10 Vdc
- - - - - COMMUNICATIONS
- - -
0
- No serial output
- - -
1
- not available
- - -
2
- Isolated RS-485 half duplex
- - - - - INPUT SIGNAL
- - - -
-V5
0-750 Vac user programmable
- - - -
-C5
0-5 A ac user programmable
All dollar amounts on this site are shown in US currency.

 Note: *Output options are not field installable.

See specifications for user programmable input ranges.

   
Keywords: 1/8 DIN High Accuracy True-RMS Scalable Indicator for AC Sinusoidal and Non-Sinusoidal Signals,