The
INFPS Series pressure standard incorporates features
found in high-end standards into an affordable, portable benchtop
unit. The microprocessor-based controller allows the user to
adjust display filtering for the particular application. The
front panel tare allows zeroing of the display with a single
pushbutton.
|
Testing
pressure switches is done by utilizing the display hold
capabilities of the microprocessor. An external connection
is completed when the pressure switch under test changes
state. The switch freezes the display, which shows the
true actuating pressure.
The microprocessor allows adjusting of the unit for
increased or decreased resolution. All options associated
with the INFS panel meter are available on this benchtop
unit. Combining the INFPS with its unique options
can turn the unit into a sophisticated data collection
system. Scalable analog outputs, RS-232 or RS-485 communications
and mechanical relays are all available options with
the INFPS.
|

OMEGADYNE™
Load
Cells
available from NEWPORT®
|
SPECIFICATIONS
Accuracy: 0.25% FS (linearity, hysteresis and repeatability)
Operating Temp.: 0 to 50°C (32 to 122°F)
Media Temp.: -20 to 80°C (-4 to 176°F)
Temp. Effects: .004% FS/°C
Proof Press.: 150% FS
Output: 4 open collectors 150 mA sink @ 1 Vdc max; optional
2 SPDT relays 7 amp @ 230 Vac; deadband fully adjustable
Warmup to Rated Accuracy: 5 min.
A/D Conversion: Dual slope technique
Display: 6-digit, 14-segment LED, red or green; 14.2
mm H (0.56"); indicator lights for alarms and status modes
RS-232 Communications Option: 300/1200/2400/4800/9600/19.2k
baud; RJ11 4-wire connection; complete program setup and message
display capability; programmable to transmit current display,
alarm status, min/max, actual measured input value (not scaled)
and status
RS-485 Communications Option: 300/1200/2400/4800/9600/19.2k
baud; RJ11 6-wire connection; addressable from 0 to 199
Analog Output Option: Selectable 0-5 Vdc, 1-5 Vdc, 0-10
Vdc, 0-20 mA 4-20 mA; voltages @ 20 mA, current @ 12 Vdc
Read Rate: 3/second (adjustable to 13/second)
Power: 120 Vac @ 10 watts
Size: 109 H x 259 W x 254 mm D (4.3 H x 10.2 W x 10"
D)
Weight: 3.6 kg (5 lb)
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with power cord, operator's manual, and calibration certificate. Serial output models include 6’ of interconnecting cable with telephone plug connectors.
Ordering Example: (1) INFPS-0000-P1K Benchtop pressure standard, 0.25% accuracy, 115 Vac power, red LED display, open collector outputs, 0 to 1000.0 psig range = $795
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
POWER AND LED COLOR
|
| |
Select 0 for Designates 115 Vac power and red LED display 1 for Designates 230 Vac power and red LED display
|
(2)
|
BCD AND CONTROL OUTPUT(S)
|
| |
Select 0 for Four optically isolated open-collector outputs 2 for Isolated dual 7 A relays (REL1) 3 for Isolated dual 7 amp and dual 1 amp relays (REL4)
|
(3)
|
ANALOG OUTPUT
|
| |
Select 0 for No analog output 1 for Isolated analog output (0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V) (AN02)
|
(4)
|
SERIAL OUTPUTS
|
| |
Select 0 for No serial output 1 for Isolated RS-232 serial output (RS20) 2 for Isolated RS-485 serial addressable output (RS40)
|
(5)
|
INPUT RANGE
|
| |
Select P15 for 0-15.000 PSIG P30 for 0-30.000 PSIG P60 for 0-60.000 PSIG P100 for 0-100.00 PSIG P300 for 0-300.00 PSIG P600 for 0-600.00 PSIG P1K for 0-1000.0 PSIG P3K for 0-3000.0 PSIG P6K for 0-6000.0 PSIG
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | |
|
 |
 |
|
|
|
|
Back to top |
|
|