INFS
 |
6
Digits |
 |
Optional
Split Meter System |
 |
Four
Isolated Open Collector Outputs |
 |
Wide
Selection of dc Voltage and Current Ranges |
 |
Ratiometric
Inputs |
 |
Tare |
 |
1.5
to 11 and 24 Vdc Sensor Excitation |
 |
Peak
and Valley Detection and Memory |
 |
Large
Digital Offset Capabilities Enabling Easy Scaling in Engineering
Units |
 |
Smart
Filtering Detects the Difference Between a Spike or Process
Change (Patent Applied For) |
 |
Selectable
Decimal Point and Read Rates of up to 13 Readings/Sec |
 |
Configurable
Via Front Pushbuttons or Via RS-232 or RS-485 |
OPTIONS
 |
Isolated
Dual 7 Amp Form C Relays |
 |
Isolated
Parallel BCD Output |
 |
Isolated
Analog Output of 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc
and 4-20 mA dc |
 |
Isolated
Serial RS-232 |
 |
Isolated
RS-485, Addressable up to 199 Units |
The
INFINITY®
strain gage meter can be configured, via the five front-panel
pushbuttons and/or the optional serial communications boards,
to accept any of a variety of dc voltage ranges (some ranges
plus unipolar or bipolar are first selected via a jumper located
at the top of the instrument housing) and display them in engineering
units.
The INFW scale meter offers the same features as the
INFS strain meter, plus it is easily integrated into your data
acquisition systems, PLCs or other computer-controlled systems
with the optional inputs. Other features include dual relay
of BCD output, isolated analog output, RS-232 or RS-484 serial
communications options, auto or sequential tare, class selection,
and display of units of measure. Self-diagnostics are performed
automatically on power-up.
These meters provide both software and hardware lockout configurations
which let you define the parameters, from setpoint adjustment
to total reprogramming. Users can scale and offset their input
signal into any engineering units desired. This is accomplished
by the use of an exclusive two-data point method of scale and
offset that eliminates the signal errors transmitted from a
sensor. The meter provides a choice of sensor excitations of
1.5 to 11 Vdc or 24 Vdc for sensors such as load cells, strain
gages, and pressure transducers.
INFZS
Split Meter with remote display 

 |
Low
Range Constant
Moment Beam Load Cell
with 4-Direction Overload Stops

Available
from
OMEGADYNE,
INC. |
SPECIFICATIONS
Accuracy: ±0.005% rdg
Span Temperature Coefficient: ±15 ppm/°C
Step Response: 1 sec to 9.9%
Warm-up to Rated Accuracy: 50 min
Operating Ambient: 0 to 50°C (32 to 122°F), 95%RH, non-condensing
Storage Ambient: -40 to 85°C (-40 to 185°F)
Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc
Power Consumption: 6 W nominal, 10 W max.
Normal Mode Rejection: 60 dB
Common Mode Rejection: 120 dB
Common Mode Voltage: 1500 V peak per Hv test
Conversion: dual-slope technique
Resolution: 15-bit
Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec,
50 Hz
Display: red or green 6-digit, 14-segment, 13.7 mm (0.54");
4 alarm indicators
Dimensions: 48 H x 96 W x 165 D mm (1.89" x 3.78" x 6.5")
Panel Cutout: 45 H x 92 W mm (1.772" x 3.622"); 1/8 DIN
Weight: 574 g (1.27 lb)
TTL Outputs: four, isolated open collector; rated 150
mA at 1 V sink, 30 V open
BCD Output: isolated, tri-state, TTL/CMOS compatible;
external 5 V supply for isolated; internal 5 V supply for non-isolated
Dual Relays: form C, 7 A at 30 Vdc or 230 Vac
Four Relay Option: dual 7A relays and dual 1 A relays
Analog Output: 0-5 V/1-5 V/0-10 V/0-20 mA/4-20 mA, user
selectable; 354 Vp isolation; 14-bit resolution; 0.1% accuracy,
50 msec step response
RS-232 Communications: 300/600/1200/2400/4800/9600/19.2k
baud; RJ11 4-wire connection; complete program setup and message
display capability; programmable to transmit current display,
alarm status, min/max, actual measured input value and status
RS-485 Communications: 300/600/1200/2400/4800/9600/19.2k
baud; RJ12 6-wire connection; addressable from 0 to 199
Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V,
0-10 V, 0-100 V, ±50 mV, ±500 mV, ±5 V, ±50
Current Input Ranges: 0-20 mA, 4-20 mA
Input Configuration: single-ended
Polarity: unipolar/bipolar, programmable
Span Adjustment: +0.00001 to 500,000, programmable
Offset Adjustment: 0 to 999,999 or 0 to -99,999; programmable
Sensor Excitation: 10 V at 30 mA for bridge; 24 V at
25 mA for loop power
To
Order (*
insert number code to complete model number)
|
Basic
Model
|
Power/
Display
|
Control
Output
|
Analog
Output
|
Serial
Output
|
Input
Signal
|
Description
|
|
INFS
|
(
* )
|
(
* )
|
( * )
|
(
* )
|
(
* )
|
Strain
gage/load cell panel meter |
|
|
(
* )
|
(
* )
|
(
* )
|
(
* )
|
(
* )
|
Strain
meter with remote display |
| - |
0
|
- |
- |
- |
- |
115
Vac power, red LED display |
| - |
1
|
- |
- |
- |
- |
230
Vac power, red LED display |
| - |
2
|
- |
- |
- |
- |
115
Vac power, green LED display |
| - |
3
|
- |
- |
- |
- |
230
Vac power, green LED display |
| - |
4
|
- |
- |
- |
- |
10-32
Vdc power, red LED display* |
| - |
5
|
- |
- |
- |
- |
10-32
Vdc power, green LED display* |
| - |
- |
0
|
- |
- |
- |
Four
NPN open collector transistors |
| - |
- |
1
|
- |
- |
- |
Isolated
parallel BCD |
| - |
- |
2
|
- |
- |
- |
Two
7 A relays |
| - |
- |
3
|
- |
- |
- |
Two
7 A relays and two 1 A relays** |
| - |
- |
- |
0
|
- |
- |
No
analog output |
| - |
- |
- |
1
|
- |
- |
Isolated
analog output |
| - |
- |
- |
- |
0
|
- |
No
serial output |
| - |
- |
- |
- |
1
|
- |
Isolated
RS-232 |
| - |
- |
- |
- |
2
|
- |
Isolated
RS-485 |
| - |
- |
- |
- |
- |
(
* )
|
Specify
range signal from chart below.* |
** 4 Relay option is not available with 10-32 Vdc Power Option
INPUT
SIGNAL
|
Range
Code
|
Range
|
|
Range
Code
|
Range
|
|
Range
Code
|
Range
|
|
DC1
|
0-100
mV
|
|
DC5
|
0-10
Vdc
|
|
DC9
|
±5
Vdc
|
|
DC2
|
0-1
Vdc
|
|
DC6
|
0-100
Vdc
|
|
DC10
|
±50
Vdc
|
|
DC3
|
0-5
Vdc
|
|
DC7
|
±50
mVdc
|
|
C1
|
0-20
mA
|
|
DC4
|
1-5
Vdc
|
|
DC8
|
±500 mVdc
|
|
C2
|
4-20
mA
|
ADD-ON-OPTIONS
|
Model
|
Description
|
|
Model
|
Description
|
|
BL
|
Blank
Lens |
|
9SC4
|
9-pin
RS-485 connector |
|
FS
|
Special
Calibration |
|
25SC2
|
25-pin
RS-232 connector |
|
9SC2
|
9-pin
RS-232 connector |
|
25SC4
|
25-pin
RS-485 connector |
|
|
|
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) INFS-0200-DC7 INFINITY® strain input meter, 115 Vac power, red LED display, dual 7 A relays, configured for ±50 mV input = $645
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Meter Type
|
| |
Select INFS for STRAIN meter INFZS for STRAIN split meter with remote display
|
(2)
|
Power and LED Color
|
| |
Select 0 for Designates 115 Vac power and red LED display 1 for Designates 230 Vac power and red LED display 2 for Designates 115 Vac power and green LED display 3 for Designates 230 Vac power and green LED display 4 for Designates 10-32 Vdc power and red LED display 5 for Designates 10-32 Vdc power and green LED display
|
(3)
|
BCD and Control Outputs
|
| |
Select 0 for Four optically isolated open-collector outputs 1 for Isolated parallel BCD output (BCD1) 2 for Isolated dual 7 A relays (REL1) 3 for Isolated dual 7 amp and dual 1 amp relays (REL4), not available with DC power
|
(4)
|
Analog Output
|
| |
Select 0 for No analog output 1 for Isolated analog output (AN03)
|
(5)
|
Serial Outputs
|
| |
Select 0 for No serial output 1 for Isolated RS-232 serial output (RS24) 2 for Isolated RS-485 serial addressable output (RS24)
|
(6)
|
Input Options
|
| |
Select DC1 for Process or Strain range 0-100 mV DC2 for Process or Strain range 0-1 V DC3 for Process or Strain range 0-5 V DC4 for Process or Strain range 1-5 V DC5 for Process or Strain range 1-10 V DC6 for Process or Strain range 0-100 V DC7 for Process or Strain range ±50 mV DC8 for Process or Strain range ±500 mV DC9 for Process or Strain range ±5 V DC10 for Process or Strain range ±50 V C1 for Process or Strain range 0-20 mA C2 for Process or Strain range 4-20 mA
|
(7)
|
Add-on Options
|
| |
Select Nothing(leave field blank) for no options ,BL for Blank Lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | |
|
 |
 |
|
|
|
|
Back to top |
|
|