The INFINITY®
The INFU universal meter is ideal for those who want
a single meter to cover a variety of input needs. This meter
can measure a broad spectrum of dc voltage and current ranges,
nine thermocouple types, a variety of RTDs, a multitude of
inputs from pressure transducers, load cells, strain gages
as well as potentiometric inputs. Six full digits make this
meter ideal for demanding process control applications. On-board
excitation is included so you can power virtually any sensor
or transmitter, and four standard setpoints give the flexibility
to control or alarm your system completely. The various setpoints
can be configured as active above or below, latching or non-latching,
as either high deviation, low deviation or band deviation,
as well as numerous other possibilities.
The meter is delivered configured for the input type you choose.
The meter can be easily reconfigured using the front pushbuttons
or via either of the optional serial communications boards.
All options are field installable, so you can easily upgrade
as your needs change.

SPECIFICATIONS
Accuracy: ±0.005% rdg
Span Temperature Coefficient: ±20 ppm
Step Response: 1 sec to 99.9%
Warmup to Rated Accuracy: 50 min
Operating Ambient: 0 to 50°C (32 to 122°F), 95%RH,
non-condensing
Storage Ambient: -40 to 85°C (-40 to 185°F)
Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc
Power Consumption: 6 W nominal, 10 W max.
Normal Mode Rejection: 60 dB
Common Mode Rejection: 120 dB
Common Mode Voltage: 1500 V peak per Hv test
Resolution: 17-bit
Conversion: dual-slope technique
Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec,
50 Hz
Display: red or green 6-digit, 14-segment, 13.7 mm
(0.54"); 4 alarm indicators
Dimensions: 48 H x 96 W x 165 D mm (1.89" x 3.78" x
6.5")
Panel Cutout: 45 H x 92 W mm (1.772" x 3.622"); 1/8
DIN
Weight: 574 g (1.27 lb)
TTL Outputs: four, isolated open collector; rated 150
mA at 1 V sink, 30 V open
BCD Output: isolated, tri-state, TTL/CMOS compatible;
external 5 V supply for isolated; internal 5 V supply for
non-isolated
Dual Relays: form C, 7 A at 30 Vdc or 230 Vac
Four Relay Option: dual 7A relays and dual 1 A relays
Analog Output: 0-5 V/1-5 V/0-10 V/0-20 mA/4-20 mA,
user selectable; 354 Vp isolation; 14-bit resolution; 0.1%
accuracy, 50 msec step response
RS-232 Communications: 300/600/1200/2400/4800/9600/19.2k
baud; RJ11 4-wire connection; programmable to transmit current
display, alarm status, min/max, actual measured input value
and status
RS-485 Communications: 300/600/1200/2400/4800/9600/19.2k
baud; RJ12 6-wire connection; addressable from 0 to 199
Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V,
0-10 V, 0-100 V, ±50 mV, ±500 mV, ±5 V, ±50 V
Current Input Ranges: 0-20 mA, 4-20 mA
Input Configuration: single-ended
Polarity: unipolar/bipolar, programmable
Span Adjustment: +0.00001 to 500,000, programmable
Offset Adjustment: 0 to 999,999 or 0 to -99,999, programmable
Thermocouple Input Types: J, K, T, E, R, S, B, N, J
DIN
RTD Input: any 6 to 6k (ohm) NIST or DIN platinum and
any linear RTD
RTD Connection: 2, 3 or 4-wire
Sensor Break Protection: upscale or downscale, programmable
Sensor Excitation: 10 V at 30 mA for bridge; 24 V at
25 mA for loop power
|
|
Input
Type
|
Range,
°F
|
Range,
°C
|
Accuracy
|
|
|
Iron-Constantan
|
-346
to 1400°F
|
-210
to 760°C
|
0.2°C
/ 0.3°F
|
|
|
Chromel-Alumel
|
-454
to 2500°F
|
-270
to 1372°C
|
0.2°C
/ 0.3°F
|
|
|
Copper-Constantan
|
-454
to 752°F
|
-270
to 400°C
|
0.2°C
/ 0.3°F
|
|
|
Chromel-Constantan
|
-454
to 1832°F
|
-270
to 1000°C
|
0.2°C
/ 0.3°F
|
|
|
Pt/Rh
|
-58
to 3214°F
|
-50
to 1768°C
|
0.2°C
/ 0.3°F
|
|
|
Pt/30%
Rh-Pt/6° Rh
|
+212
to 3300°F
|
+100
to 1820°C
|
0.3°C
/ 0.5°F
|
|
|
Nicrosil-Nisil
|
-454
to 2372°F
|
-270
to 1300°C
|
0.2°C
/ 0.3°F
|
|
|
Iron-Constantan
|
-328
to 1652°F
|
-200
to 900°C
|
0.6°C
/ 1.0°F
|
|
Input Type
|
Range, °F |
Range, °C |
Range, °K |
Accuracy* |
| RTD 1 - 10ohm Copper |
-328 to 392°F |
-200 to 200°C |
73.2 to 473.2°K |
1.0°C/2.0°F/1.0K |
| RTD 2 - 0.00385 100ohm Pt |
-328 to 1652°F |
-200 to 900°C |
73.2 to 1173.2°K |
0.2°C/0.3°F/0.2K |
| RTD 3 - 0.00392 100ohm Pt |
-328 to 1562°F |
-200 to 850°C |
73.2 to 1123.2°K |
0.2°C/0.3°F/0.2K |
|
|
|
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) INFU-0000-DC1 INFINITY® UNIVERSAL input meter, 115 Vac power, red LED display, open collector outputs, configured for 0-100 mV input = $645
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Meter Type
|
| |
Select INFU for INFINITY® UNIVERSAL input meter INFZU for UNIVERSAL input split meter with remote display
|
(2)
|
Power and LED Color
|
| |
Select 0 for Designates 115 Vac power and red LED display 1 for Designates 230 Vac power and red LED display 2 for Designates 115 Vac power and green LED display 3 for Designates 230 Vac power and green LED display 4 for Designates 10-32 Vdc power and red LED display 5 for Designates 10-32 Vdc power and green LED display
|
(3)
|
BCD and Control Outputs
|
| |
Select 0 for Four optically isolated open-collector outputs 1 for Isolated parallel BCD output (BCD1) 2 for Isolated dual 7 A relays (REL1) 3 for Isolated dual 7 amp and dual 1 amp relays (REL4), not available with DC power
|
(4)
|
Analog Output
|
| |
Select 0 for No analog output 1 for Isolated analog output (AN03)
|
(5)
|
Serial Outputs
|
| |
Select 0 for No serial output 1 for Isolated RS-232 serial output (RS24) 2 for Isolated RS-485 serial addressable output (RS24)
|
(6)
|
Input Options
|
| |
Select DC1 for Process or Strain range 0-100 mV DC2 for Process or Strain range 0-1 V DC3 for Process or Strain range 0-5 V DC4 for Process or Strain range 1-5 V DC5 for Process or Strain range 1-10 V DC6 for Process or Strain range 0-100 V DC7 for Process or Strain range ±50 mV DC8 for Process or Strain range ±500 mV DC9 for Process or Strain range ±5 V DC10 for Process or Strain range ±50 V C1 for Process or Strain range 0-20 mA C2 for Process or Strain range 4-20 mA TC for J K E T B S N or DIN J Thermocouple RTD1 for 10 ohm Copper RTD RTD2 for 100 ohm Pt RTD with 0.00385 alpha RTD3 for 100 ohm Pt RTD with 0.00392 alpha
|
(7)
|
Temperature Units (Thermocouple/RTD configurations)
|
| |
Select Nothing(leave field blank) for not configured (process/strain input) C for °C (Celsius) F for °F (Fahrenheit) K for Kelvin
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | |
|
 |
 |
|
|
|
|