Virtual Chart Recorder
View Temperature + Humidity with a Web Browser
| Features |
 |
Virtual Chart Recorder |
 |
Web Server |
 |
Alarms by Email or Text Message |
 |
Data Logging |
 |
Accurate Readings |
 |
iTHX-SD: Record Years of Data on Popular SD Cards |
 |
No Special Software Required |
|
|
|
| |
The NEWPORT® iTHX transmitter let's you monitor and record Temperature, Relative Humidity and Dew Point over an Ethernet network or the Internet with no special software except a Web Browser.
The NEWPORT iTHX serves Active Web Pages to display real time readings, display charts of temperature and humidity, or log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic.
The virtual chart viewed on the web page is a JAVA™ Applet that records a chart over the LAN or Internet in real time. With the NEWPORT iTHX, there is no need to invest time and money learning a proprietary software program to log or chart the data.
Adjustable Charts
Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 124°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). When a second sensor is added, users can select a chart that records channel 1, channel 2 or the difference of the two channels.
Display and Chart Two Channels
The iTHX transmitters come complete with a temperature and humidity probe for measurement of a single location. With the addition of a second probe, the iTHX transmitter can measure and display humidity, temperature and dew point in a second location up to ten feet away.
The transmitter can display and chart absolute measurements in both locations, or a differential measurement between the two locations. The second probe requires no change to the basic iTHX transmitter hardware.
A second probe can be added at the time of purchase or in the future. NEWPORT offers a choice of industrial probes in 2" and 5" lengths, and a wand style for ambient indoor applications. A simple DB-9 "Y" connector is available for adding a second probe to model iTHX-W and iTHX-SD.
No connector is required to add a second probe to the DIN rail mounted iTHX-2.
|

Display of Two Channels on
Read Sensor Web Page
Industrial Probes:
iTHP-5 and iTHP-2
|
Award-winning Technology
The NEWPORT iTHX is simple to install and use, and features NEWPORT's award-winning iServer technology that requires no special software except a Web Browser. The iTHX connects to an Ethernet Network with a standard RJ45 connector and sends data in standard TCP/IP packets. It is easily configured with a simple menu using a Web Browser and can be password protected. From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name such as "Cleanroom5" or "ServerRoom" in any Web Browser, and the iTHX serves a Web Page with the current readings.
Email Alarms
All NEWPORT iTHX models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user or a distribution list anywhere in the world, including text messages to cell phones and PDA's.
Typical Applications
The NEWPORT iTHX is great for monitoring temperature + humidity in applications such as: clean rooms, computer rooms, HVAC systems, pharmaceutical and food processing and storage, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, greenhouses, farm animal shelters, and many more.
|
NEW iTHX-SD
The NEWPORT model iTHX-SD with LCD display, adds several valuable features in addition to the backlit local display of temperature and humidity.
SD Flash Memory Card
The iTHX-SD comes complete with a removable 2 GB SD Flash Memory card that can store up to seven years of readings taken at ten second intervals.
Records on SD Flash Cards
The data is recorded on widely available SD (Secure Digital) flash cards. The format is a simple “.txt” text file that is easily imported to spread sheets and other programs. It can be read on a PC or MAC with a USB card reader. You can also download the data remotely over an Ethernet network or the Internet. |
|
Alarm Relays
The iTHX-SD features two 1.5 Amp relays. With the easy Web-based setup page, the two relays can be programmed for any combination of temperature or humidity, and high or low set points. The relays can also be programmed to remain latched and require a manual reset if a limit is exceeded.
Battery Backup
The iTHX-SD comes with a universal 100 to 240 Vac power adapter. A standard 9 Volt Alkaline battery (also included) allows the device to log data for up to 2 days without external ac power. A failure on the Ethernet network will not interrupt data recording.
Link to Web CAM or IP Camera
The iTHX-SD Web page includes a link to a “Web Cam” or “IP camera” (not included). If you get a message about an alarm condition, you can quickly click on the link to view the actual scene over the Internet.
NEWPORT iServer products are designed and manufactured in Santa Ana, California.
|
Specifications
Sensor Specifications
Relative Humidity (RH)
Accuracy/Range: ±2% for 10 to 90%
±3% for 5 to 10% and 90 to 95%
±4% for 0 to 5% and 95 to 100%
Non-linearity: ±3%
Hysteresis: ±1% RH
Response Time: 8 seconds, tau 63%
Repeatability: ±0.1%
Resolution: 0.1%, 12 bit |
Temperature (T)
Accuracy/Range*:
Wand Probe:
±0.5°C for 5 to 45°C (±1°F for 41° to 113°F);
±0.5 to ±1°C for 0 to 5°C and 45 to 70°C
(±1° to ±2°F for 32 to 41°F and 113 to 158°F)
Industrial Probe:
±0.5°C for 5 to 45°C (±1°F for 41 to 113°F);
±0.5° to ±1.5°C for -40 to 5°C and 45 to 124°C
(±1° to ±2.7°F for -40 to 41°F and 113 to 255°F)
(see chart)
*Note: extended temperature range is for Industrial Probe only, the iServer's operating temp. is 0 to 70 °C.
Response Time: 5 to 30 seconds, tau 63%
Repeatability: ±0.1°C
Resolution: 0.1°C, 14 bit
|

|
Probe Specifications
Wand Probe iTHP-W-6:
Ø19 mm x 198 mm L (0.75" x 7.8" L )
Cable length: 152mm (6”) with DB9 Connector
Cable operating temp: 0°C to 80°C (32°F to 176°F)
Industrial Probe iTHP-5, iTHP-2:
Ø16mm x 137mm or 51mm L (0.63” x 5” or 2” L )
Housing material: SS 316
Cable length: 3m (10’) or 0.9m (3’)
Cable operating temperature: -40°C to 125°C
(-40°F to 257°F)
|
|
Optional Caps available for
Industrial Probes. |
iServer Specifications
Interfaces
Ethernet (RJ45): Fixed or autonegotiating 10/100BASE-T, Auto MDI/MDIX for iTHX-SD;
10BASE-T for iTHX-W, iTHX-2
Sensor: Digital 4-wire (DB-9) for iTHX-W, iTHX-SD; removable 8 position screw terminals for iTHX-2
Supported Protocols
TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet for iTHX-SD;
TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet for iTHX-W, iTHX-2
LCD Display
16 Digits 6mm (0.23") for iTHX-SD
SD Flash Memory Card
2GB card: 8 months of data storage at 1 second recording intervals or 7 years at 10 second intervals for iTHX-SD
Relay Outputs
Two Relays 1.5A @ 30 Vdc for iTHX-SD
Management
Device configuration and monitoring through embedded WEB server (Fig.1)
Embedded WEB Server
Serves WEB pages containing real-time data (Fig. 2)
and live updated charts within definable time intervals (Fig. 3). |
Power (iTHX-W, iTHX-SD)
Power Input: 9 to 12 Vdc for iTHX-W, iTHX-SD
Consumption: 2.5 W max.for iTHX-W;
3.5 W max.for iTHX-SD
Safety Qualified ac Power Adapter (included) for
iTHX-W, iTHX-SD
Nominal Output: 9 Vdc @ 0.5 A
Input: 100 to 240 Vac, 50/60 Hz

Universal ac Power Adapter
Back-up Battery: 9Vdc, Alkaline for iTHX-SD
|
Power (iTHX-2)
Power Input: 10 to 32 Vdc
Consumption: 2.5 W max.
Switching Power Supply: iDRN-PS-1000 sold separately

iDRN-PS-1000
|
Environmental
Operating Temperature
iTHX-2, iTHX-W: 0 to 70°C (32 to 158°F)
iTHX-SD: 0 to 60°C (32 to 140°F)
ac Power Adapter: 0º to 40ºC (32º to 104ºF)
Back-up Battery: -18 to 55°C (0 to 131°F)
Packaging
Material: Steel metal case with wall mount bracket for iTHX-SD
Valox 364 PBT case with wall mount bracket for iTHX-W
Polycarbonate case with DIN Rail mount for iTHX-2
Dimensions: Refer to Mechanical Section
iTHX-W
iTHX-SD
iTHX-2
Weight: 0.18 kg (0.4 lbs.) iTHX-W
0.389 kg (0.86 lbs.) iTHX-SD
0.113 kg (0.25 lbs.) iTHX-2
Agency Approvals
Calibration
|
Software
Firmware upgradeable over Ethernet for iTHX-SD.
Firmware upgradeable (for iTHX-W and iTHX-2 iServer firmware upgrade package, (EIS-FW-CA and iTHX-FW-CD) contact Newport oem@newportUS.com or 714-540-4914)
OPC Server;
Configuration Software utility (iCONNECT);
macro for datalogging in Excel program iLOG (Fig. 4 and Fig. 5);
compatible with Windows operating systems
|
Fig. 3- WEB page displaying the graph of the received data
iTHX-2/iTHX-W and iTHX-SD

Fig. 4 – iLOG Excel program logging the data sent by the iTHX

Fig. 5 – iLOG Excel program sketching the data sent by the iTHX
Mechanical Dimensions
DOWNLOAD CAD FILES - iTHX-W & iTHX-SD |
WEB FORMAT |
AUTOCAD 2000 |


|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
iServer MicroServer™ Models
|
| |
Select iTHX-W for iServer MicroServer™ for Temperature + Humidity + Dew Point iTHX-SD for iServer MicroServer™ for Temperature + Humidity + Dew Point with LCD Display and 2 GB SD Flash Card iTHX-2 for DIN Rail mount iServer MicroServer™ for Temperature + Humidity + Dew Point
|
(2)
|
Probe Options
|
| |
Select Nothing(leave field blank) for Standard 8" Wand Probe. -2 for Industrial 2" Probe and 3' Cable with (substitution for standard Probe) -5 for Industrial 5" Probe and 10' Cable (substitution for standard Probe-not available with iTHX-2)
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
|
|
 |
 |
|
|
|
|