The L2Q9 and L4Q9 use the signal conditioner modules,
which makes them compatible with most common sensor types. The
P signal conditioner module accepts voltage inputs up to 10 Vdc
or current inputs up to 50 mA. For use with millivolt sensors,
such as load cells or strain gages, the S signal conditioner accepts
inputs up to 500 mV. Both the P and S models are fully scalable
to read out in engineering units from ±9999 counts. The S models
also have a 20 Vdc power supply for transducer excitation. Additional
models for J, K, and T thermocouples and 100 Ohm platinum RTDs
are also available. All large displays utilize a switching power
supply which enables them to operate on any ac voltage between
95 and 265 Vac and 45 to 440 Hz.
SPECIFICATIONS
Power: 95 to 265 Vac, 45 to 440 Hz
Power Consumption: 10 watts
Display Type: High efficiency red LED
Digit Height: L2Q: 2 1/4" (57 mm); L4Q: 4" (102 mm)
Operating Temperature: 32 to 122°F (0 to 50°C) (reduced
to 40°C if maximum display brightness is selected)
Storage Temperature: -4 to 185°F (-20 to 85°C)
Humidity: 85% RH non-condensing
Dimensions: L2Q: 10.4" W x 4.7" H x 4.6" D (264 x 120 x
117 mm); L4Q: 19" W x 7" H x 4.6" D (480 x 180 x 117 mm)
Panel Cutout: L2Q: 10.2" W x 4.5" H (258 x 114 mm); L4Q:
18.6" W x 6.8" H (474 x 174 mm)
Depth Behind Panel: 4.2" (107 mm)
Weight: L2Q: 5.5 lb. (2.5 kg); L4Q: 9.9 lb. (4.5 kg)
Case Material: aluminum extrusion, black anodized finish
Power Connector: IEC fused connector, 6' (1.8 m) power
cord included
Signal Connector: mating 9 pin sub-miniature D-type or
thermocouple input socket (SMP) for signal conditioner types J,
K and T, included
To Order (Specify Model No.)
Prices Shown in U.S. Dollars
|
Model
No.
|
Description
|
Price
|
|
L2Q2-R-(*)
|
3
1/2-digit large display panel meter with 2 1/4" (57 mm) high
digits |
$1415
|
|
L4Q2-R-(*)
|
3
1/2-digit large display panel meter with 4" (102 mm) high digits |
$2105
|
|
L2Q9-R-(*)
|
4-digit
large display panel meter with 2 1/4" (57 mm) high digits |
$1415
|
|
L4Q9-R-(*)
|
4-digit
large display panel meter with 4" (102 mm) high digits |
$2105
|
*
Insert Signal Conditioner Order Code from table above.
Comes complete with power cord, mating input connectors, operator's
manual and ferrite cores.
Ordering
Example:
L2Q9-R-JDC1 is a 4-digit large display meter with a 2 1/4"
(57 mm) high display, and type J thermocouple input with -40 to
760°C range, $1415 + 125 = $1540.
SIGNAL
CONDITIONERS
|
Model
No.
|
Order
Code
|
Range
|
Price
|
|
Process Current/Voltage |
P
|
Scalable
|
$100
|
|
Strain Gage/Millivolt |
S
|
Scalable
|
$175
|
| Frequency/Rate
Inputs |
H
|
Scalable
|
$125
|
|
J Thermocouple (°F) |
JDF1
|
-40
to 1400°F
|
$125
|
| J
Thermocouple (°C) |
JDC1
|
-40
to 760°C
|
$125
|
| K
Thermocouple (°F) |
KDF1
|
-40
to 1999°F
|
$125
|
| K
Thermocouple (°C) |
KDC1
|
-40
to 1260°C
|
$125
|
| T
Thermocouple (°F) |
TDF1
|
-300
to 700°F
|
$125
|
| T
Thermocouple (°C) |
TDC1
|
-184
to 371°C
|
$125
|
|
RTD 1° Resolution (°F) |
MDF1
|
-328
to 1526°F
|
$125
|
| RTD
1° Resolution (°C) |
MDC1
|
-200
to 830°C
|
$125
|
| RTD
0.1° Resolution (°F) |
RDF1*
|
-199.9
to 199.9°F
|
$125
|
|
RTD 0.1° Resolution (°C) |
RDC1*
|
-199.9
to 199.9°C
|
$140
|
*Not
recommended for use with L2Q9 or L4Q9 4-digit meters.
NOTE: Maximum temperature range for L2Q9 and L4Q9 is 999.9