The P5000 microprocessor-based, 6-digit, 1/8 DIN panel instrument
can be configured by front-panel keys or by a personal computer as
a frequency meter/ tachometer, frequency-ratio meter, period/ period-average
meter, time-interval/time-interval-average meter, reset stopwatch,
and cumulative timer or totalizer/1-stage batch controller. However,
the P5000 display cannot toggle between rate and total. Two signal
inputs can be used to provide frequency ratio or time-interval measurements.
Five Operating Modes
In the frequency meter, the minimum display update rate is equal to
1 period of the frequency input. Thus, very low frequency measurements
are displayed and updated faster than most conventional frequency
meters. Only two sensors are required to measure the rate of a moving
object. The P5000 can be set up as frequency-ratio meter, ideal for
monitoring flow ratios.
The P5000 can be set up as an up or down totalizer/1-stage batch controller
at rates up to 7 MHz. The display capacity is –99,999 to 999,999 counts
with exponential format up to 9.99 E9. Upon ac power loss, the latest
reading is automatically saved in non-volatile RAM and is restored
upon return of power.
SPECIFICATIONS
TTL INPUT
Speed and Protection Levels (jumper selectable): 7 MHz, 0-5
V; 100 kHz, -20 to +25 V; 3 kHz, -20 to +25 V
Isolated Input Sensitivity (square-wave input): ±10 mV, 0 to
1 kHz; ±25 mV, 0 to 1 kHz; ±50 mV at 100 kHz Requires PGA1
NPN or PNP Open-Collector Sensor Excitation Output: 12.4 V
at 20 mA
COMMON
SPECIFICATIONS (All Input Types)
Number of Inputs: 1 or 2 (2 inputs for frequency ratio and
time interval only)
Update Rate: 60 msec to 99.99 sec, field programmable
OPERATION MODES
Frequency/Tachometer Mode– Frequency Range: 10-6 Hz to 7 MHz
Accuracy at 25°C (square wave): ±0.0002% (+2 ppm)
Totalizer Display–Offset (preset): –99,999 to 999,999
ISOLATED ANALOG INPUT
Accuracy: better than 99.9%
Non-Linearity: 0.05% FS
Isolation: 350 Vdc between output and input
Power: 230 Vac, 10-32 Vdc
AC Frequency: 49-440 Hz
Power Consumption, Typical: 7.5 W max.
Battery Backup: user-supplied 6-12 Vdc, 60 mA to maintain operation,
400 mA with display
Dimensions: 1.9" H x 3.8" W x 5.9" D (48 x 96 x 150 mm); 1.77"
x 3.62" (45 x 92 mm ) cutout
ON/OFF CONTROL & ALARM OUTPUTS
Standard: three open-collector transistors, rated 150 mA sink,
30V
Optional:
two form C relays rated 8 A, 30 Vdc, or 240 Vac, resistive load (for
rate alarm or batch control)
Input
Options
‘0’ = Standard input, dual-channel input board, non-isolated TTL/5
V CMOS-level, frequency range of 10-6 to 7 MHz. Default calibration:
0 to 10 kHz = 0 to 10000.0.
‘1’ = Isolated single-channel input board with sensor excitation,
protected for signals up to 260 Vac. (P6A1). Default calibration:
0 to 10 kHz = 0 to 10000.0.
‘2’ = Non-isolated dual-channel input board with sensor excitation.
Protected for input signals up to 260 Vac RMS. (P6A2). Default
calibration: 0 to 10 kHz = 0 to 10000.0
‘3’ = Non-isolated single-channel input board with sensor excitation.
Protected for input signals up to 60 Vac RMS. (P6A3). Default calibration:
0 to 10 kHz = 0 to 10000.0
‘4’ = Isolated analog-to-frequency single-channel input with
24 Vdc, 0-1 mA, 4-20 mA dc, 1-5 Vdc, and 0-10 Vdc (P6A5).
|
|
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) P5031 Ratemeter or totalizer with isolated signal input and analog output = $715
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
Option Descriptions
|
(1)
|
Power
|
|
Select 0 for Designates 115 V ac, 49/440 Hz power (P60A) 1 for Designates 230 V ac, 49/440 Hz power (P61A) 4 for Designates 9.5 to 32Vdc power (P64A)
(2)
|
Control Output Option
|
|
Select 0 for None 1 for Isolated, tri-state parallel BCD output. Includes 50-pin mass-termination connector (P6D1A) 2 for Dual 8A Form “C” SPDT relays. Includes screw clamp connector (P6T1A)
(3)
|
Signal Conditioner
|
|
Select 0 for TTL/5Vcmos is standard. Single input for frequency and totalize modes 1 for Isolated signal conditioner, single-channel, with sensor excitation output. Shipped jumpered for zero debounce time, and 10 mV hysteresis (P6A1A) 2 for Isolated signal conditioner, dual-channel, with sensor excitation output. Shipped jumpered for zero debounce time, and 10 mV hysteresis (P6A2A) 3 for Non-isolated signal conditioner, single-channel, with sensor excitation output. Shipped jumpered for 15µs debounce time, and 40 mV hysteresis (P6A3) 4 for Analog to frequency converter (Isolated) with 24 Vdc excitation output, for 0-1 mA, 4-20mA, 0-5V, 1-5V, or 0-10Vdc input. Ideal for Integrating Totalizer applications. Shipped jumpered for 4/20mA (P6A5B)
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| |
|
 |
 |
|
|
|
Keywords: INFINITY® 6-Digit Multi-function Meter for Batch Control, Rate Indication & Totalization
|
Back to top |
| |