| OPTIONS |
 |
Dual
8 A Form C relays |
 |
Parallel
BCD output, isolated |
 |
Analog
output, isolated and scalable, 4-20 mA, 0-20 mA, 0-10 V |
 |
9-32
V isolated DC power |
 |
Plain
front panel without programming keys |
The P6004
is a special configuration of the six-digit P6000 microprocessor-based
rate meter and counter with an isolated analog-to-frequency signal
conditioner. The result is a 1/8 DIN software-scalable process meter
or integrating totalizer with an exceptionally wide display range,
two setpoints and RS-232. Standard input ranges are 4-20 mA, 0-10
V or 0-2 V, with fine zero and span input adjustments at the rear
of the meter.
PROCESS INDICATOR MODE
The analog-to-frequency signal conditioner converts the analog process
signal to a frequency from 1 Hz to 10 kHz. In the process indicator
mode, this frequency is scaled to engineering units (such as PSI
or liters/s) by a six-digit multiplier or divider with any decimal
point. An exceptionally wide six digits of zero offset are also
available. For instance, this offset can allow the P6004 to display
the water level of a canal to 0.1 inch resolution at 1,000 feet
above sea level, based on 4-20 mA signal from a pressure transducer
at the bottom of the canal and the known altitude of the canal.
The display
update time can be programmed in 10 ms steps from 50 ms plus one
pulse period to 99.99 s. The longer update times provide improved
noise rejection by time-averaging the signal.
In the process indicator mode, the accuracy of the P6004 is 99.9%
at 25°C, as for most 3 1/2 digit meters with dual-slope integration.
The temperature coefficient is a low 50 ppm/°C. The number
of digits to the right of the decimal point is program-selectable
with true roundoff so as to eliminate non-significant digits.
INTEGRATING TOTALIZER MODE
In the
totalizer mode, the 1 Hz to 10 kHz output from the analog-to-frequency
signal conditioner is totalized, then scaled to engineering units
by a six-digit multiplier or divider with any decimal point. For
instance, this allows the P6004 to accept the 4-20 mA signal from
a linear flowmeter and display volume in liters or gallons, or to
accept the 0-10 V signal from a wattmeter and display kW-hrs.
Six digits of preset (display offset) are available, and the P6004
may count up from zero to this preset (positive multiplier or divider)
or down from this preset to zero (negative multiplier or divider).
In case of a power failure, the latest reading is automatically
saved in non-volatile RAM and is restored with power. A low-level
cutoff may be jumper-selected to disable totalizing below 0.27%
of maximum signal.
SIMULTANEOUS RATE AND TOTAL
Rate and total can be displayed simultaneously and can each have
their own HI and LO setpoints if a basic P6000 is used in combination
with a P6004. This is achieved by bringing out the TTL-level 1 Hz
to 10 kHz pulses from the analog-to-frequency signal conditioner
of the P6004 and using them as input to the basic P6000.
LOCAL OR REMOTE PROGRAMMING
1.
FRONT-PANEL PROGRAMMING
The P6004 can be programmed manually at the front panel, which
provides five programming keys and alphanumeric prompting through
the LED display. If desired, all setup parameters can be stored
in non-volatile RAM. To prevent unauthorized or inadvertent program
changes, the P6004 provides four levels of front-panel lockout using
push-on jumpers. The front panel can be locked out completely, be
locked out except for setpoints, or be fully usable except for fine-calibration
of the crystal clock. Saving program changes in non-volatile RAM
can also be locked out, so that previously stored setup parameters
can always be recalled.
Once the program is stored in non-volatile RAM, an optional front
panel without keys can be substituted for the standard front panel
with keys.
The P6004 can also be programmed remotely by downloading setup parameters
from a host computer via RS-232 using direct wiring or a modem.
It is well suited for ATE and other computer-controlled applications,
since the host computer or programmable controller can dynamically
change all setup parameters, including setpoints, and receive data
via RS-232. To aid in programming, an IBM PC compatible 5i1/4
inch floppy disk with a menu-driven setup program is available as
a low-cost option.
DATA, ALARM AND CONTROL OUTPUTS
RS-232 and 20 mA serial ASCII communications are standard on
the main board, as are three open-collector outputs rated 30 V,
150 mA. The P6004 also offers a choice of three upper-board options:
Isolated parallel BCD output allows the P6004 to be interfaced
to programmable controllers and to Newport's Model 820A printer.
The combination of a P6004 with an 820A constitutes a low-cost datalogging
system, where the readings are tagged with time and date.
Dual 8 A Form C relays allow the P6004 to switch resistive
loads up to 2 kW for alarm and control applications.
Isolated analog output provides jumper selection of 0-10
V or 4-20 mA and adjustable zero and span. The 0-10 V output is
ideal to drive a stripchart recorder. The 4-20 mA output effectively
turns the P6004 into an isolated transmitter.
SPECIFICATIONS
ANALOG INPUT
|
Signal
range
|
4-20
mA
|
0-2
V
|
0-10
V
|
|
Maximum
Input
|
22
mA
|
2.1
V
|
11
V
|
|
Input
resistance
|
56 ohm
|
20
kohm
|
100
kohm
|
Output to main meter: 1 Hz to 10 kHz
Low-level shutoff: Jumper selection to disable output below
27 Hz (0.27% of full scale)
Zero adjust: ±5% of full scale via potentiometer
Span adjust: 6-digit software multiply or divide, any decimal
point
ISOLATION
& NOISE REJECTION
CMV,
SIG GND to PWR GND or DIG GND: 1500 Vp per HV test, 354 Vp per
IEC spacing
CMR, SIG GND to PWR GND or DIG GND: 100 dB
NMR, SIG HI to SIG LO: 32 dB, 50/60 Hz (in process meter
mode at 400 ms update time)
ACCURACY AT 25°C
Nonlinearity, max: ±0.05% of full scale
Accuracy at 25°C: 99.9% of reading
Warmup to rated accuracy: 1 hr
Response time, min for 10% to 90% for step input: 200 ms
Time for display averaging: Programmable, 0 to 99.9 s
Tempco, 4-20 mA or 0-10 V: ±0.005%R/°C (50 ppm/°C)
Tempco, 0-2 V: ±0.01%R/°C (100 ppm/°C)
DISPLAY
Type: 7-segment, red LED
Digit: 0.56 in (14.2 mm)
Symbols: 8.8.8.8.8.8
Display scaling: 6-digit multiply or divide, any decimal
point
Display offset (or count preset): 6-digits, any decimal point
Decimal points: Programmable number of digits to right of
decimal point with true roundoff, or 6-digit display with autoranging
Display overrange: Exponential notation to 9.99 E9
RS-232
/ 20 mA ASCII COMMUNICATIONS (STD)
Baud
rate: 1200 or 9600
RS-232 voltage levels: +5 V, 6 V
RS-232 connections: Data out, data in, RTS, GND
20 mA ASCII connections: Data out, GND
Receive capability: Complete program setup
Transmit capability: Readings with decimal point, sign, alarm
status, unit of measurement, setup data
CONTROL, ALARM & DATA OUTPUTS
1. MAIN BOARD (STD)
Setpoint output: Three open-collector transistors
Power rating: 150 mA sink, 30 V
2. DUAL-RELAY
UPPER BOARD (OPT)
Output type: Two form-C relays
Power rating: 8 A, 30 V dc or 240 V ac, resistive load
3. ISOLATED
PARALLEL BCD UPPER BOARD (OPT)
BCD type: Isolated, buffered, gated tri-state
Digit addressing: 3 or 6 digits at a time
Output level: TTL/CMOS, 10 LSTTL loads
Power: External 5 V dc for isolated BCD, internal 5 V dc
for non-isolated BCD
4.
ISOLATED ANALOG OUTPUT UPPER BOARD (OPT)
Output
level (source): 4-20 mA, 0-20 mA, 0-10 V (jumper-selectable)
Compliance for 20 mA source: 12 V
Compliance for 10 V source: 20 mA
Isolation, SIG GND to ANA GND: 500 Vp
Resolution: 1/2048 of output span (11 bits)
Accuracy, 10 - 40°C: ±0.1% of theoretical value
Step response, 10% to 90% of full-scale: 50 ms
Zero and span adjust: Via screwdriver from rear of case
Turndown ratio (max zero offset ÷ by min span): 20:1
ENVIRONMENTAL
Operating temperature: 0 to 60°C
Storage temperature: 40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)
MECHANICAL
Environmental protection: Splash-resistant front panel
(std) NEMA-12 lens cover (opt)
Dimensions: Newport DIN 4896-150 (1/8 DIN) case, 150 mm behind
panel
Weight: 21 oz (590 g)
Case material: 94V-0 UL-rated polycarbonate
ELECTRICAL
CONNECTIONS
Signal,
power, and dual-relay upper-board option: Push-in cable connectors
with screw clamping
RS232/20 mA ASCII: 10-pin dual-row male header on meter (standard),
10-pin dual-row female cable connector (D10D option)
Control I/O functions: 20-pin dual-row male header on meter
(standard), 20-pin dual-row female cable connector (D20D option)
Parallel BCD upper-board option: 50-pin dual-row male header
on meter plus
50-pin dual-row female cable connector (both standard)
Note: The male dual-row headers and female cable connectors
are per DIN 41612 and provide .100" x .100" (2.54 x 2.54mm)
pin spacing. The cable connectors allow mass termination or individual
wire connections without soldering by using needle-nose pliers or
a hand-insertion tool like 3M 3430-01000.
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Each unit comes complete with operator's manual.
Ordering Example: (1) P6004A rate meter and counter with isolated analog-to-frequency signal conditioner, 115 Vac power = $515
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Power
|
| |
Select 0 for 115 Vac 49-440 Hz power 1 for 230 Vac 49-440 Hz power 4 for 9.5 to 32 Vdc power
|
(2)
|
Control Output(s)
|
| |
Select 0 for no control outputs 1 for isolated tri-state parallel BCD output 2 for dual 8 A form C SPDT relays 3 for isolated and scalable analog output
|
(3)
|
Add-On Options
|
| |
Select Nothing(leave field blank) for no options ,FS for special calibration configuration ,BL for blank lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| |
|
 |
 |
|
|
|
|
Back to top |
|
|