Navigation image map
Contact Us Distributor Site Map Manuals Home Products


PLATINUM™ Series Temperature, Process and Strain Digital Panel Meters
PTDP_Series

PLATINUM™ Series  Temperature, Process and Strain Digital Panel Meters
Strain & Bridge Inputs, 6 Digit Display and Upgraded Platinum Software Now Available
High Performance (20 Samples / Sec)
High Accuracy
Extremely Versatile yet Easy and Intuitive to Use
Bright 3-Color (RED, GREEN, and AMBER) 9 Segment LED Display with Wide Viewing Angle
Universal Inputs for Thermocouples, RTD’s, Thermistors, Process Voltage/Current, Strain & Bridge
No Jumpers to Set, Totally Firmware Configurable
Flexible Alarm Programming, Optional Alarm Relays
Standard USB, Optional Ethernet and RS232/ RS485 with MODBUS® Serial Communications
UL and cUL Certified
Controller versions are also available
PLATINUM Demonstrator Kit are also available

1 Year Warranty Electromagnetic Compatibility Underwriter Laboratories New

Scroll Below to Order Specs Manuals Quickstarts Software Literature

The Industry Leading PLATINUM™ Series family of microprocessor-based digital panel meters offer unparalleled flexibility in process measurement. While extremely powerful and versatile, great care has gone into designing a product that is very easy to set-up and use. The automatic hardware configuration recognition eliminates the need for jumpers and allows the firmware to automatically simplify itself, eliminating all menu options that do not apply to a specific configuration.

Each unit allows the user to select the input type from 9 thermocouple types (J, K, T, E, R, S, B, C, and N), Pt RTDs (100, 500, or 1000 Ω, with either 385, 392, or 3916 curve), thermistors (2250 Ω, 5K Ω, and 10K Ω), DC voltage, or DC current, and Strain & Bridge Inputs. The bipolar voltage or current inputs are fully scalable to virtually all engineering units, with a selectable decimal point that is perfect for use with pressure, flow, or other process input.

Two alarms can be configured for above, below, hi/lo, and band triggering using either absolute or deviation alarm trigger points. In addition, high-high/low-low indication is available. The two optional single pole double throw mechanical relays can be assigned to either or both alarm triggers. Two annunciators and three display colors can also be assigned to the alarm triggers.

The PLATINUM™ Series device features a large, 3-color, 9 segment programmable LED display with the capability to change color and/ or change the state of designated outputs every time an alarm is triggered. Now 6-digit display is available. The universal power supply accepts 90 to 240 Vac. The low voltage power option accepts 24 Vac or 12 to 36 Vdc.

Embedded Ethernet and Serial Communications
Optional embedded ethernet on the 1⁄16 and 1⁄8 DIN models allow the units to connect directly to an ethernet network and transmit data in standard TCP/IP packets, or serve web pages over a LAN or the internet. Optional serial communications are also available configurable as RS232 or RS485, with straightforward ASCII commands or MODBUS®. All three types of communications interfaces (USB, ethernet, and serial) can be installed and active simultaneously.

Specifications
Inputs
Input Types: Thermocouple, RTD, thermistor, analog voltage, analog current, strain & bridge inputs
Current Input: 4 to 20 mA, 0 to 24 mA scalable
Voltage Input:±100 mV, ±1 V, ±10 Vdc scalable
Thermocouple Input (ITS 90): K, J, T, E, R, S, B, C, N
RTD Input (ITS 90): 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves
Thermistor Input: 2252 Ω, 5K Ω, 10K Ω
Strain Input: ±100 mV, ±50 mV
Excitation: Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 Vdc @ 25 mA (24V for AC Units Only)
Configuration: Differential
Polarity: Bipolar
Resolution: 0.1° temperature; 10 μV process
Input Impedances:
    Process Voltage: 10M Ω for ±100 mV, 1M Ω for other voltage ranges
    Process Current: 5 Ω
    Thermocouple: 10K Ω max
Temperature Stability:
    RTD: 0.04°C/°C
    Thermocouple @ 25°C (77°F): 0.05°C/°C (cold junction compensation)
    Process: 50 ppm/°C
A/D Conversion: 24-bit sigma delta
Reading Rate: 20 samples per second
Digital Filter: Programmable from 0.05 seconds (filter = 1) to 6.4 seconds (filter = 128)
CMRR: 120 dB
Setpoint Adjustment: 4 Digit (-9999 to +9999 counts); 6 Digit (-99999 to +999999)
Warm-Up to Rated Accuracy: 30 mins
Alarm outputs (optional)
Isolated Analog output (optional): Retransmission only
SPDT Relay: Single pole, double throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load)
Communications (USB Standard , Optional Serial and Ethernet)
Connection:
    USB: Female micro-USB
    Ethernet: Standard RJ45
    Serial: Screw terminals
USB: USB 2.0 host or device
Ethernet Standards Compliance: IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET
Serial: Software selectable RS232 or RS485; programmable 1200 to 115.2 K baud
Protocols: Omega ASCII, Modbus ® ASCII/RTU
Isolation
Approvals: UL, cUL, CE
Power to Input/Output: 2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option)
Power to Relays/SSR Outputs: 2300 Vac per 1 min test
Relays/SSR to Relay/SSR Outputs: 2300 Vac per 1 min test
RS232/RS485 to Inputs/Outputs: 500 Vac per 1 min test




Input Type Description Range Accuracy
Process/Strain Process Voltage ±50 mV, ±100 mV, ±1, ±10 Vdc 0.03% FS
Process Process Current Scalable within 0 to 24 mA 0.03% FS
J Iron-Constantan -210 to 1200°C (-346 to 2192°F) 0.4°C (0.7°F)
K CHROMEGA®-ALOMEGA® -270 to -160°C (-454 to -256°F)
-160 to 1372°C (-256 to 2502°F)
1.0°C (1.8°F)
0.4°C (0.7°F)
T Copper-Constantan -270 to -190°C (-454 to -310°F)
-190 to 400°C (-310 to 752°F)
1.0°C (1.8°F)
0.4°C (0.7°F)
E CHROMEGA®-Constantan -270 to -220°C (-454 to -364°F)
-220 to 1000°C (-364 to 1832°F)
1.0°C (1.8°F)
0.4°C (0.7°F)
R Pt/13%Rh-Pt -50 to 40°C (-58 to 104°F)
40 to 1788°C (104 to 3250°F)
1.0°C (1.8°F)
0.5°C (0.9°F)
S Pt/10%Rh-Pt -50 to 100°C (-58 to 212°F)
100 to 1768°C (212 to 3214°F)
1.0°C (1.8°F)
0.5°C (0.9°F)
B 30%Rh-Pt/6%Rh-Pt 100 to 640°C (212 to 1184°F)
640 to 1820°C (1184 to 3308°F)
1.0°C (1.8°F)
0.5°C (0.9°F)
C 5%Re-W/26%Re-W 0 to 2320°C (32 to 4208°F) 0.4°C (0.7°F)
N Nicrosil-Nisil -250 to -100°C (-418 to -148°F)
-100 to 1300°C (-148 to 2372°F)
1.0°C (1.8°F)
0.4°C (0.7°F)
RTD Pt, 0.00385, 100 Ω, 500 Ω, 1000 Ω -200 to 850°C (-328 to 1562°F) 0.3°C (0.7°F)
RTD Pt, 0.003916, 100 Ω -200 to 660°C (-328 to 1220°F) 0.3°C (0.7°F)
RTD Pt, 0.00392, 100 Ω -200 to 660°C (-328 to 1220°F) 0.3°C (0.7°F)
Thermistor 2252 Ω -40 to 120°C (-40 to 248°F) 0.2°C (0.35°F)
Thermistor 5K Ω -30 to 140°C (-22 to 284°F) 0.2°C (0.35°F)
Thermistor 10K Ω -20 to 150°C (-4 to 302°F) 0.2°C (0.35°F)

Accessories
Use the optional PT-USB-CABLE for a NEMA4 rated panel mount USB connector. A 12" (304mm) length cable connects from USB port of Platinum controller to your control panel. This accessory includes a protective end cap when not in use.

The PT-USB-ADAPTER, which is supplied with each unit, can be plugged into the controller and be used with a standard USB 2.0 memory stick.



PT-USB-CABLE


The PT-USB-1 1 GB USB thumbdrive has a standard USB connector on one end and a micro-USB connector on the other end. It is convenient for transferring files between your PC and your PLATINUM unit.



PT-USB-1

The part numbers listed below are only examples. Many more configurations are offered and can be constructed using the part number builder at the bottom of this page.


Product Selection (Specify Model Number, see variations below in partnumber builder table)
 Part Number   Availability   Price    Description   
 PtDP32 in-stock    $160.00     1/32 DIN 4-digit display Meter with USB Communications  
 PtDP32-330 in-stock    $200.00     1/32 DIN 4-digit display Meter with 2 Alarm Relays and USB Communications  
 PtDP32-C24-DC in-stock    $250.00     1/32 DIN 4-digit display Meter with USB and RS232 / RS485 Serial Communications, 12-36 Vdc Powered  
 PtDP32-330-C24 in-stock    $265.00     1/32 DIN 4-digit display Meter with 2 Alarm Relays, USB and RS232 / RS485 Serial Communications  
 PtDP16-DC in-stock    $220.00     1/16 DIN 4-digit display Meter with USB Communications, 12-36 Vdc Powered  
 PtDP16-330 in-stock    $235.00     1/16 DIN 4-digit display Meter with 2 Alarm Relays and USB Communications  
 PtDP16-EIP-DC in-stock    $290.00     1/16 DIN 4-digit display Meter with USB and Ethernet Communications, 12-36 Vdc Powered  
 PtDP8 in-stock    $235.00     1/8 DIN 4-digit display Meter with USB Communications  
 PtDP16-330-C24-EIP-DC in-stock    $395.00     1/16 DIN 4-digit display Meter with 2 Alarm Relays, USB, RS232 / RS485 Serial and Ethernet Communications, 12-36 Vdc Powered  
 PtDP8-330-DC in-stock    $300.00     1/8 DIN 4-digit display Meter with 2 Alarm Relays and USB Communications, 12-36 Vdc Powered  
 PtDP8-330-C24-DC in-stock    $365.00     1/8 DIN 4-digit display Meter with 2 Alarm Relays, USB abd RS232 / RS485 Serial Communications, 12-36 Vdc Powered  
 PtDP8-330-EIP in-stock    $345.00     1/8 DIN 4-digit display Meter with 2 Alarm Relays, USB and Ethernet Communications  
 PtDP8-330-006 in-stock    $340.00     1/8 DIN 4-digit display Meter with 2 Alarm Relays and Isolated Analog Output  
 PtDP8E in-stock    $295.00     1/8 DIN 6-digit display Meter with USB communication  
 Accessories
 PT-USB-ADAPTER in-stock    $7.35     Standard USB to Micro USB Adapter  
 PT-USB-CABLE in-stock    $15.80     USB Micro to Standard Cable with Panel Mount Connector  
 PT-USB-1 in-stock    $15.80     1 GB Double-Ended USB Stick (Male Micro and Male Standard)  
 
All dollar amounts on this site are shown in US currency.

 Note: Comes complete with quickstart manual with downloadable operator’s manual. Free DASHBOARD software can be downloaded for use with a PC to log data from the unit on the PC via any installed communications channel.

All units come with USB communications standard but the Ethernet communications option is not available on 1/32 DIN models.

For Calibration: when ordering a CAL-3, default input is K type T/C in degree C. Please contact sales if other input types are needed
 Part Number Builder
(1) (2) (3) (4) (5) (6)
P
P
t
t
D
D
P
P
Option Descriptions
(1) DIN Size
  Select
32 for 1/32 DIN 4-digit Single Display
16 for 1/16 DIN 4-digit Single Display
8 for 1/8 DIN 4-digit Single Display
8E for 1/8 DIN 6-digit Single Display
(2) Alarm Relays
  Select
Nothing(leave field blank) for Not Installed
-330 for 2 Mechanical Relays for Alarms
(3) Isolated Outputs
  Select
Nothing(leave field blank) for Not Installed
-006 for for for One Isolated Analog Output(1/8 DIN only)
(4) Serial Communications
  Select
Nothing(leave field blank) for Not Installed
-C24 for RS232 / RS485 Serial Communications
(5) Ethernet
  Select
Nothing(leave field blank) for Not Installed
-EIP for Ethernet Communications and Web Server (Not Available on 1/32 DIN Models)
(6) Power Source
  Select
Nothing(leave field blank) for Standard AC Powered
-DC for 12 to 36 Vdc Powered
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   
Keywords: Panel Meters, Panel Meter, Temperature Meter, Process Meter, Temperature Meters, Process Meters, Alarm, Strain Meter

   Back to top