3 1/2 DIGIT THERMOCOUPLE METERS, TRANSMITTERS & CONTROLLERS
MODEL Q2000J / Q2000K / Q2000T
Electromagnetic Compatibility

NEWPORT PRODUCT INFO
MANUAL - PDF Version QxxxxJ
MANUAL - PDF Version QxxxxK
MANUAL - PDF Version QxxxxT
MECHANICAL 1/8 DIN (1A) Case
MECHANICAL Connections Diagram
PRICE
REQUIRES ADOBE ACROBAT - HELP
STANDARD FEATURES
Thermocouple types J, K, T
­300 to +1999-count display span
1°C or 1°F resolution
Internal reference junction
Sensor-break detection
120 dB CMR to 500 V
1 mV/count linearized analog output
LED or LCD display
Display hold and test
120/240 V ac, 5 V dc, 9-32 V dc or 26-56 V dc power
Screw-terminal barrier strip
1/8 DIN case
   
OPTIONS
Analog output for user-selected span
Single-setpoint 10 A relay control
Dual-setpoint 10 A relay control
Proportional 4-20 mA control
Time-proportional 2 A SS relay control
Parallel BCD output, isolated
NEMA-4 splash-proof lens cover

QUANTA Models Q2000J, Q2000K and Q2000T
are 3 1/2 digit indicator/controllers for thermocouple types J, K and T, respectively. They are complete with linearization, cold-junction compensation, and sensor-break detection. Readout is in °C or °F with 1° resolution, as selected by push-on jumpers. What makes QUANTA exceptional is the wide choice of options.

INPUT POWER AND DISPLAY OPTIONS
Six types of meter power are available: 120 V ac, 240 V ac, 24 V ac, 5 V dc, isolated 9-32 V dc and isolated 26-56 V dc. An LED display is standard. An LCD display is optional and is recommended for viewing in bright ambient light.


ANALOG OUTPUT OPTIONS
A 1 mV/count (±2 V full-scale) analog output is standard and is useful for driving a strip-chart recorder. An additional analog output can be provided by an optional vertical plug-in board. Available output signals are 0-5 V dc, 0-10 V dc, 0-1 mA (source or sink), and 4-20 mA (source or sink). The top and bottom of each output range can be scaled to fit a user-selected display span.

CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal upper board. Available options include single-setpoint control with one 10 A relay, dual-setpoint control with two 10 A relays, 4-20 mA proportional control (source or sink), time-proportional 2 A solid-state relay control, and isolated, parallel BCD output. For additional information, please refer to the QUANTA, Options, and Mechanical sections.


SPECIFICATIONS

ANALOG INPUT
TC types: J (Iron-Constantan), K (Chromel-Alumel), T (Copper-Constantan)
Calibration: To IPTS-68, as published in NIST monograph 125 (March 1974), ASTM E130-72 or ASA C96.2-1973
Configuration: Single-ended (-TC lead connected to ANA GND)
Input resistance: 100 Mohm
Sensor-break detection: 400 nA current source
Max lead resistance for rated accuracy: 500ohm (type J ohm), 395ohm (type K ohm), 200ohm (type T ohm)
Zero tempco (cold-junction error): ±0.06 deg/deg
Span tempco, 10°C to 40°C: ±0.01% of reading/°C


NOISE REJECTION
NMR: 70 dB at 50/60 Hz
Overvoltage protection: 120 V rms (continuous), 240 V rms (30 s max)
CMR: 120 dB with 250 ohm imbalance
CMV: 1500 Vp per HV test, 354 Vp per IEC spacing

ANALOG-TO-DIGITAL CONVERSION
Input configuration: Single-ended SIG HI (TC + ) lead connected to SIG GND through 10ohm
Technique:
Dual-slope, average-value
Polarity: Automatic
Signal integration period:
100 ms
Read rate: 2.5/s

DISPLAY
LED: 0.56 in (14.2 mm) 7-segment, red
LCD: 0.50 in (12.7 mm) 7-segment liquid crystal
Symbols: ­1.8.8.8
Decimal point positions: Three positions selectable by jumpers behind lens or at connector
Sensor-break indication: Three least-significant digits blanked

POWER
AC voltages:
120, 240, 100 or 24 V ac +10%/­15%
AC frequency: 49-440 Hz
DC voltages: 9-32 V dc, isolated to 300 Vp; 26-56 V dc, isolated to 300 Vp; 5 V dc ±5%, non-isolated
Power consumption: 10 W max

ENVIRONMENTAL
Operating temperature:
0 to 60°C
Storage temperature: ­40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)

MECHANICAL
Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical section for drawings)
Weight: 17 oz (480 g)
Case material: 94V-0 UL-rated polycarbonate

Thermocouple types



To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description    Qty.
 Q2000-KDF1 in-stock    $305.00     Quanta meter,3-1/2 digit display, red LED display, 120 Vac power, 1 mV per count analog output, type K thermocouple input with -40 to 1400°F range (no control output)  
 Q9000-KDC1 in-stock    $345.00     Quanta meter,4 digit display, red LED display, 120 Vac power, 1 mV per count analog output, type K thermocouple input with -40.0 to 999.9°C range (no control output)  
 Q2020-TDF1 in-stock    $395.00     Quanta meter,3-1/2 digit display, red LED display, 120 Vac power, 0 to 10 Vdc analog output, type T thermocouple input with -300 to 700°F range (no control output)  
 Q9001-JDC1 in-stock    $510.00     Quanta meter,4 digit display, red LED display, 120 Vac power, 1 mV per count analog output, dual setpoint 10 A relay, type J thermocouple input with
-40.0 to 760.0°C range
 
 
All dollar amounts on this site are shown in US currency.

 Part Number Builder
(1) (2) (3) (4) (5) (6) (7)
Q -
Option Descriptions
(1) Display Resolution and Case Style
  Select
2 for ±1,999 counts (3 1/2 digits)
3 for ±1,999 with INFINITY FAMILY BEZEL AND ADAPTER
9 for ±9,999 counts (4 digits)
8 for ±9,999 with INFINITY FAMILY BEZEL AND ADAPTER
(2) Display Type & Meter Power - LCD
  Select
0 for LED, 120 Vac (49/440 Hz) (BQ20 or BQ90)
1 for LCD, 120 Vac (49/440 Hz) (BQ21)
2 for LED, 240 Vac (49/440 Hz) (BQ22 or BQ92)
3 for LCD, 240 Vac (49/440 Hz) (BQ23)
4 for LED, 9-32 Vdc (isolated) (BQ24 or BQ94)
5 for LCD, 9-32 Vdc (isolated) (BQ25)
6 for LED, 5 Vdc** (BQ26 or BQ96)
7 for LCD, 5 Vdc** (BQ27)
8 for LED, 24 Vac (BQ28 or BQ98)
9 for LCD, 24 Vac (BQ29)
A for LED, 26-56 Vdc (isolated) (BQ2A or BQ9A)
B for LCD, 26-56 Vdc (isolated) (BQ2B)
(3) Analog Output Adders
  Select
0 for ±1 or ±2 V recorder output, non-isolated. (standard)
1 for 0-5 Vdc, non-isolated (BA01)
2 for 0-10 Vdc, non-isolated (BA01)
3 for 0-1 mA, source or sink, non-isolated (BA01)
4 for 4-20 mA, source or sink, non-isolated (BA01)
5 for 4-20 mA, sink (high-compliance), non-isolated. (BA02)
6 for 4-20 mA, ISOLATED (BA03)
(4) Control Output Adders
  Select
0 for None
1 for Dual-setpoint 10 A relay. (BDT1)
2 for Proportional 4-20 mA control, source or sink (BDP1)
3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control, source or sink. (BDP2)
4 for BCD (isolated, latched, buffered, byte addressable). Includes 50-pin mass-termination connector. (BDD2)
5 for Single-setpoint 10 A relay (BDS1)
(5) Signal Conditioning Input Adders
  Select
JDC1 for Type J Thermocouple input -40 to 760°C (Q2000/Q3000) or -40.0 to 760.0°C (Q8000/Q9000) (BSCJ)
JDF1 for Type J Thermocouple input -40 to 1400°F (Q2000/Q3000) or -40.0 to 999.9°F (Q8000/Q9000) (BSCJ)
KDC1 for Type K Thermocouple input -40 to 1260°F (Q2000/Q3000) or -40.0 to 999.9°C (Q8000/Q9000) (BSCK)
KDF1 for Type K Thermocouple input -40 to 1999°F (Q2000/Q3000) or -40.0 to 999.9°F (Q8000/Q9000) (BSCK)
TDC1 for Type T Thermocouple input -184 to 371°C (Q2000/Q3000) or -184.0 to 371.0°C (Q8000/Q9000) (BSCT)
TDF1 for Type T Thermocouple input -300 to 700°F (Q2000/Q3000) or -300.0 to 700.0°F (Q8000/Q9000) (BSCT)
(6) Display Color
  Select
Nothing(leave field blank) for Red Display (standard)
,G for Green Display
(7) Lens
  Select
Nothing(leave field blank) for Standard Lens (with Newport logo)
,BL for Blank Lens
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   