3 1/2 DIGIT OHMMETER,
TRANSMITTER & CONTROLLER
MODEL Q2000O
DISPLAY
AND POWER OPTIONS
The
QUANTA Model Q2000O is available with an LED or an LCD display
and with six types of meter power: 120 Vac, 240 Vac, 24 Vac, 5 Vdc,
9-32 Vdc (isolated) and 26-56 Vdc (isolated).
ANALOG OUTPUT
OPTIONS
A 1 mV/count (±2 V full-scale) analog output is standard and
is ideal for driving a strip-chart recorder. An additional analog
output can be provided by an optional vertical plug-in board. Available
output signals are 0-5 Vdc, 0-10 Vdc, 0-1 mA (source or sink), and
4-20 mA (source or sink). The top and bottom of each output range
can be scaled to fit a user-selected display span.
CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal upper board. Available
options include single-setpoint control with one 10 A relay, dual-setpoint
control with two 10 A relays, 4-20 mA proportional control (source
or sink), time- proportional 2 A solid-state relay control, and isolated,
parallel BCD output. The 10A relay options are ideal for ATE and material
testing applications, which require ON/OFF control. The BCD output
can communicate with programmable controllers and Newport's Model
872A thumbwheel controller. For additional information, please refer
to the QUANTA and Mechanical sections.
SPECIFICATIONS
INPUT
|
Range
|
19.99
ohm
|
199.9
Kohm
|
1.999
Kohm
|
19.99
Kohm
|
|
Resolution
|
10
mohm
|
100
mohm
|
1
ohm
|
10
ohm
|
|
Excitation
Current
|
4.2
mA
|
4.2
mA
|
420
µA
|
42
µA
|
INPUT
CONFIGURATION
Connection:
2- or 4-wire
Zero adjustment: ±50 counts
Overvoltage protection (differential): 15 Vp
Open-circuit voltage (max): 12 V
NOISE REJECTION
NMR:
50 dB, 50/60 Hz
CMR:
120 dB
CMV: 1500 Vp per HV test, 354 Vp per IEC spacing
ACCURACY AT 25°C
Overall accuracy:
±0.05% of
reading ±1 count
Span tempco: ±0.006% of reading/°C
Zero tempco: ±2.5 m/°C ±0.001% of FS/°C
Warmup to rated accuracy: 1 min
ANALOG-TO-DIGITAL CONVERSION
Input
configuration: Differential, bipolar
Technique: Dual-slope, average-value
Polarity: Automatic
Signal integration period: 100 ms
Read rate: 2.5/s
DISPLAY
LED:
0.56 in (14.2 mm) 7-segment, red
LCD: 0.50 in (12.7 mm) 7-segment liquid crystal
Symbols: 1.8.8.8
Decimal-point positions: Three positions selectable by jumpers
behind lens or at connector
Overrange or break indication: Three least-significant digits
blanked
POWER
AC voltages: 120, 240, 100 or 24 Vac +10%/15%
AC frequency: 49-440 Hz
DC voltages: 9-32 Vdc, isolated to 300 Vp; 26-56 Vdc, isolated
to 300 Vp; 5 Vdc ±5%, non-isolated
DC power consumption: 8 W max
ENVIRONMENTAL
Operating temperature: 0 to 60°C
Storage temperature: 40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)
MECHANICAL
Dimensions:
Newport DIN1A (1/8 DIN) case (See Mechanical section for drawings)
Weight: 17 oz (480 g)
Case material: 94 V-0 UL-rated polycarbonate
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Display Resolution and Case Style
|
| |
Select 2 for ±1,999 counts (3 1/2 digits) 3 for ±1,999 with INFINITY FAMILY BEZEL AND ADAPTER
|
(2)
|
Display Type & Meter Power - LCD
|
| |
Select 0 for LED, 120 Vac (49/440 Hz) (BQ20 or BQ90) 1 for LCD, 120 Vac (49/440 Hz) (BQ21) 2 for LED, 240 Vac (49/440 Hz) (BQ22 or BQ92) 3 for LCD, 240 Vac (49/440 Hz) (BQ23) 4 for LED, 9-32 Vdc (isolated) (BQ24 or BQ94) 5 for LCD, 9-32 Vdc (isolated) (BQ25) 6 for LED, 5 Vdc** (BQ26 or BQ96) 7 for LCD, 5 Vdc** (BQ27) 8 for LED, 24 Vac (BQ28 or BQ98) 9 for LCD, 24 Vac (BQ29) A for LED, 26-56 Vdc (isolated) (BQ2A or BQ9A) B for LCD, 26-56 Vdc (isolated) (BQ2B)
|
(3)
|
Analog Output Adders
|
| |
Select 0 for ±1 or ±2 V recorder output, non-isolated. (standard) 1 for 0-5 Vdc, non-isolated (BA01) 2 for 0-10 Vdc, non-isolated (BA01) 3 for 0-1 mA, source or sink, non-isolated (BA01) 4 for 4-20 mA, source or sink, non-isolated (BA01) 5 for 4-20 mA, sink (high-compliance), non-isolated. (BA02) 6 for 4-20 mA, ISOLATED (BA03)
|
(4)
|
Control Output Adders
|
| |
Select 0 for None 1 for Dual-setpoint 10 A relay. (BDT1) 2 for Proportional 4-20 mA control, source or sink (BDP1) 3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control, source or sink. (BDP2) 4 for BCD (isolated, latched, buffered, byte addressable). Includes 50-pin mass-termination connector. (BDD2) 5 for Single-setpoint 10 A relay (BDS1)
|
(5)
|
Signal Conditioning Input Adders
|
| |
Select OOR1 for 2- or 4-wire resistance input (BSCR) 19.99 ohm (BSCR) OOR2 for 2- or 4-wire resistance input (BSCR) 199.9 ohm (BSCR) OOR3 for 2- or 4-wire resistance input 1999 ohm (BSCR) OOR4 for 2- or 4-wire resistance input 19.99 kohm (BSCR)
|
(6)
|
Display Color
|
| |
Select Nothing(leave field blank) for Red Display (standard) ,G for Green Display
|
(7)
|
Lens
|
| |
Select Nothing(leave field blank) for Standard Lens (with Newport logo) ,BL for Blank Lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | |
|
 |
 |
|
|
|
|
Back to top |
|
|