AC
VOLTMETER, AMMETER & CONTROLLER
|
|
NEWPORT
PRODUCT INFO
|
|
|
•
REQUIRES
ADOBE ACROBAT - HELP
|
|
|
The QUANTA® AC AVG voltmeter
and ammeter use a precision op-amp rectifier circuit to provide
an economical AC-average meter, which is calibrated to display the
true-RMS value of sinusoidal signals. The QUANTA AC RMS voltmeter
and ammeter use an integrated circuit that computes the true-root-mean-square
value of complex waveforms. Screw-terminals are provided for AC
or DC coupling. AC coupling allows the measurement of the AC component
or ripple from a signal with both AC and DC components. DC coupling
allows the measurement of true-RMS, including both DC and AC components.
The signal conditioner provides six current ranges, as determined
by an internal shunt resistor. In addition, there is a special 5
A range, which allows direct connection to a current transformer
(CT) with 5 A secondary, without need for a stepdown transformer.
Proper scaling is obtained for primary currents of 10, 100 and 1000
A.
SPECIFICATIONS
ANALOG
INPUT, Q2000C & Q2000F / Q3000C & Q3000F
|
Range
|
- |
199.9
mV
|
1.999
V
|
|
Resolution
|
- |
100
µV
|
1
mV
|
|
Maximum
input
|
- |
50
Vp
|
100
Vp
|
|
Input
resistance
|
- |
1.1
Mohm
|
1.1
Mohm
|
|
Range
|
19.99
V
|
199.9
V
|
650
V
|
|
Resolution
|
10
mV
|
100
mV
|
1
V
|
|
Maximum
input
|
250
Vp
|
500
Vp
|
920
Vp
|
|
Input
resistance
|
1.0
Mohm
|
1.0
Mohm
|
10
Mohm
|
ANALOG INPUT, Q2000D & Q2000G / Q3000D
& Q3000G
|
Range
|
19.99
µA
|
199.9
µA
|
1.999
mA
|
|
Resolution
|
10
nA
|
100
nA
|
1
µA
|
|
Maximum
input
|
3
mA
|
10
mA
|
30
mA
|
|
Input
resistance
|
10
kohm
|
1
kohm
|
100ohm
|
|
Range
|
19.99
mA
|
199.9
mA
|
1.999
A
|
|
Resolution
|
10
µA
|
100
µA
|
1
mA
|
|
Maximum
input
|
100
mA
|
500
mA
|
2.2
A
|
|
Input
resistance
|
10
ohm
|
1
ohm
|
0.1
ohm
|
|
Range
|
19.99
A
|
199.9
A
|
1999
A
|
|
Resolution
|
10
mA
|
100
mA
|
1
A
|
|
Maximum
input
|
5
A CT
|
5
A CT
|
5
A CT
|
|
Input
resistance
|
0.01ohm
|
0.01ohm
|
0.01ohm
|
ANALOG INPUT, Q9000C & Q9000F / Q8000C &
Q8000F
|
Range
|
99.99
mV
|
999.9
mV
|
|
Resolution
|
10
µV
|
100
µV
|
|
Maximum
Input
|
50
Vp
|
100
Vp
|
|
Input
Resistance
|
1.1
Mohm
|
1.1
Mohm
|
|
Range
|
9.999
V
|
99.99
V
|
650.V
|
|
Resolution
|
1
mV
|
10
mV
|
100
mV
|
|
Maximum
Input
|
250
Vp
|
500
Vp
|
920
Vp
|
|
Input
Resistance
|
1.0
Mohm
|
1.0
Mohm
|
10
Mohm
|
ANALOG INPUT, Q9000D & Q9000G / Q8000D
& Q8000G
|
Range
|
9.999
µA
|
99.99
µA
|
999.9
µA
|
|
Resolution
|
1
nA
|
10
nA
|
100
nA
|
|
Maximum
Input
|
3
mA
|
10
mA
|
30
mA
|
|
Input
Resistance
|
10
kohm
|
1
kohm
|
100
ohm
|
|
Range
|
9.999
A
|
99.99
A
|
999.9
A
|
|
Resolution
|
1
mA
|
10
mA
|
100
mA
|
|
Maximum
Input
|
5
A CT
|
5
A CT
|
5
A CT
|
|
Input
Resistance
|
0.01
ohm
|
0.01
ohm
|
0.01
ohm
|
ACCURACY at 25°C (AC)
Maximum Error: ±0.1% of reading ±10 counts
Span tempco: ±0.01% of reading/°C (AC)
Step response: 1 s to 99.9% of span
Frequency range for rated accuracy: 147 to 1000 Hz
Warmup to rated accuracy: Less than 30 min.
ACCURACY at 25°C (RMS) (1% to 100%
of full scale)
Maximum error, AC coupling: ±0.1% of reading ±10 cts, 47 Hz
to 5 kHz
Maximum error, DC coupling: ±0.1% of reading ±10 cts, 9 Hz
to 5 kH
Span tempco: ±0.03% of reading/°C (typ)
Zero tempco: 0.15 mV/°C (typ)
Step response: 1 sec to 99.9% of span
Warmup to rated accuracy: Less than 30 min.
CONVERSION
Technique: Dual-slope, average-value
Signal integration period: 100 ms
Read rate: 2.5/sz
|
Range Code
|
Input Range |
| Range
Code |
True
RMS |
Q2000
/ Q3000 |
Q9000
/ Q8000 |
|
CVR2
|
FVR2
|
199.99
mV
|
99.99
mV
|
|
CVR3
|
FVR3
|
1.999
V
|
999.9
mV
|
|
CVR4
|
FVR4
|
19.99
V
|
9.999
V
|
|
CVR5
|
FVR5
|
199.9
V
|
99.99
V
|
|
CVR6
|
FVR6
|
650
V
|
650.0
V
|
|
DCR1
|
GCR1
|
19.99
µA
|
9.999
µA
|
|
DCR2
|
GCR2
|
199.9
µA
|
99.99
µA
|
|
DCR3
|
GCR3
|
1.999
mA
|
999.9
µA
|
|
DCR4
|
GCR4
|
19.99
mA
|
9.999
mA
|
|
DCR5
|
GCR5
|
199.99
mA
|
99.99
mA
|
|
DCR6
|
GCR6
|
1.999
A
|
999.9
mA
|
|
DCR7
|
GCR7
|
5 A CT
|
5
A CT
|
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Display Resolution and Case Style
|
| |
Select 2 for ±1,999 counts (3 1/2 digits) 3 for ±1,999 with INFINITY FAMILY BEZEL AND ADAPTER 9 for ±9,999 counts (4 digits) 8 for ±9,999 with INFINITY FAMILY BEZEL AND ADAPTER
|
(2)
|
Display Type & Meter Power - LCD
|
| |
Select 0 for LED, 120 Vac (49/440 Hz) (BQ20 or BQ90) 1 for LCD, 120 Vac (49/440 Hz) (BQ21) 2 for LED, 240 Vac (49/440 Hz) (BQ22 or BQ92) 3 for LCD, 240 Vac (49/440 Hz) (BQ23) 4 for LED, 9-32 Vdc (isolated) (BQ24 or BQ94) 5 for LCD, 9-32 Vdc (isolated) (BQ25) 6 for LED, 5 Vdc** (BQ26 or BQ96) 7 for LCD, 5 Vdc** (BQ27) 8 for LED, 24 Vac (BQ28 or BQ98) 9 for LCD, 24 Vac (BQ29) A for LED, 26-56 Vdc (isolated) (BQ2A or BQ9A) B for LCD, 26-56 Vdc (isolated) (BQ2B)
|
(3)
|
Analog Output Adders
|
| |
Select 0 for ±1 or ±2 V recorder output, non-isolated. (standard) 1 for 0-5 Vdc, non-isolated (BA01) 2 for 0-10 Vdc, non-isolated (BA01) 3 for 0-1 mA, source or sink, non-isolated (BA01) 4 for 4-20 mA, source or sink, non-isolated (BA01) 5 for 4-20 mA, sink (high-compliance), non-isolated. (BA02) 6 for 4-20 mA, ISOLATED (BA03)
|
(4)
|
Control Output Adders
|
| |
Select 0 for None 1 for Dual-setpoint 10 A relay. (BDT1) 2 for Proportional 4-20 mA control, source or sink (BDP1) 3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control, source or sink. (BDP2) 4 for BCD (isolated, latched, buffered, byte addressable). Includes 50-pin mass-termination connector. (BDD2) 5 for Single-setpoint 10 A relay (BDS1)
|
(5)
|
Signal Conditioning Input Adders
|
| |
Select CVR2 for AC AVG Voltage 199.9 mV (Q2000/Q3000) or 99.99 mV (Q8000/Q9000) CVR3 for AC AVG Voltage 1.999 V (Q2000/Q3000) or 999.9 mV (Q8000/Q9000) CVR4 for AC AVG Voltage 19.99 V (Q2000/Q3000) or 9.999 V (Q8000/Q9000) CVR5 for AC AVG Voltage 199.9 V (Q2000/Q3000) or 99.99 V (Q8000/Q9000) CVR6 for AC AVG Voltage 650 V (Q2000/Q3000) or 650.0 V (Q8000/Q9000) DCR1 for AC AVG Current 19.99 µA (Q2000/Q3000) or 9.999 µA (Q8000/Q9000) DCR2 for AC AVG Current 199.9 µA (Q2000/Q3000) or 99.99 µA (Q8000/Q9000) DCR3 for AC AVG Current 1.999 mA (Q2000/Q3000) or 999.9 µA (Q8000/Q9000) DCR4 for AC AVG Current 19.99 mA (Q2000/Q3000) or 9.999 mA (Q8000/Q9000) DCR5 for AC AVG Current 199.9 mA (Q2000/Q3000) or 99.99 mA (Q8000/Q9000) DCR6 for AC AVG Current 1.999 A (Q2000/Q3000) or 999.9 mA (Q8000/Q9000) DCR7 for 5 Amp Current transformer- 5 A = 199.9 A (Q2000/Q3000) or 5 A = 99.99 A (Q8000/Q9000) FVR2 for True-RMS Voltage 199.9 mV (Q2000/Q3000) or 99.99 mV (Q8000/Q9000) FVR3 for True-RMS Voltage 1.999 V (Q2000/Q3000) or 999.9 mV (Q8000/Q9000) FVR4 for True-RMS Voltage 19.99 V (Q2000/Q3000) or 9.999 V (Q8000/Q9000) FVR5 for True-RMS Voltage 199.9 V (Q2000/Q3000) or 99.99 V (Q8000/Q9000) FVR6 for True-RMS Voltage 650 V (Q2000/Q3000) or 650 V (Q8000/Q9000) GCR1 for True-RMS Current 19.99 µA (Q2000/Q3000) or 9.999 µA (Q8000/Q9000) GCR2 for True-RMS Current 199.9 µA (Q2000/Q3000) or 99.99 µA (Q8000/Q9000) GCR3 for True-RMS Current 1.999 mA (Q2000/Q3000) or 999.9 µA (Q8000/Q9000) GCR4 for True-RMS Current 19.99 mA (Q2000/Q3000) or 9.999 mA (Q8000/Q9000) GCR5 for True-RMS Current 199.9 mA (Q2000/Q3000) or 99.99 mA (Q8000/Q9000) GCR6 for True-RMS Current 1.999 A (Q2000/Q3000) or 999.9 mA (Q8000/Q9000) GCR 7 for 5 Amp Current transformer 5 A = 199.9 A (Q2000/Q3000) or Default calibration 5 A=99.99 A (Q8000/Q9000)
|
(6)
|
Display Color
|
| |
Select Nothing(leave field blank) for Red Display (standard) ,G for Green Display
|
(7)
|
Lens
|
| |
Select Nothing(leave field blank) for Standard Lens (with Newport logo) ,BL for Blank Lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | |
|
 |
 |
|
|
|
|
Keywords:AC VOLTMETER, AMMETER & CONTROLLER AVG RMS
|
Back to top |
|
|