4-Digit DC Voltmeter, Ammeter, Transmitter & Controller
Q9000A (Voltage) & Q9000B (Current)
The QUANTA Q9000A DC voltmeter and Q9000B DC ammeter
are ±9,999-count
versions of the ±1,999-count Q2000A and Q2000B, respectively.
They provide the same features and benefits (but no LCD display
option), plus additional resolution required for many applications.
A 1/8 DIN case with screw terminals for signal and power is standard.
A wide range of options are available.
POWER OPTIONS
Six types of meter power are available: 120 V ac, 240 V ac,
24 V ac, 5 V dc, isolated 9-32 V dc or 26-56 V dc.
ANALOG OUTPUT OPTIONS
A 0.1 mV/count (±1 V full-scale) analog output is standard
and is ideal for driving a strip-chart recorder. An additional
analog output can be provided by an optional vertical plug-in
board. Available output signals are 0-5 V dc, 0-10 V dc, 0-1 mA
(source or sink), and 4-20 mA (source or sink). The top and bottom
of each output range can be scaled to fit a user-selected display
span.
CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal upper board.
Available options include single-setpoint control with one 10
A relay, dual-setpoint control with two 10 A relays, 4-20 mA proportional
control (source or sink), time-proportional 2 A solid-state relay
control, and isolated, parallel BCD output. For additional information,
please refer to the QUANTA and Mechanical sections.
SPECIFICATIONS
ANALOG INPUT Q9000A
|
Range
|
±99.99
mV
|
±999.9
mV
|
±9.999
V
|
±99.99
V
|
|
Resolution
|
10
µV
|
100
µV
|
1
mV
|
10
mV
|
|
Maximum
Input
|
130
Vp
|
250
Vp
|
250
Vp
|
250
Vp
|
|
Input
resistance
|
100
Gohm
|
1
Mohm
|
1
Mohm
|
1
Mohm
|
|
Bias
current
|
1
nA
|
100
pA
|
10
pA
|
1
pA
|
ANALOG INPUT Q9000B
|
Range
|
±9.999
µA
|
±99.99
µA
|
±999.9
µA
|
|
Resolution
|
1
nA
|
10
nA
|
100
nA
|
|
Maximum
Input
|
3
mA
|
10
mA
|
30
mA
|
|
Input
resistance
|
10
kohm
|
1
kohm
|
100
ohm
|
|
Range
|
±9.999
mA
|
±99.99
mA
|
±999.9
mA
|
|
Resolution
|
1
µA
|
10
µA
|
100
µA
|
|
Maximum
Input
|
100
mA
|
500
mA
|
2.2
A
|
|
Input
resistance
|
10
ohm
|
1
ohm
|
0.1
ohm
|
INPUT CONFIGURATION
Configuration: Bipolar, single-ended
Polarity: Automatic
Span adjustment: ±4%
NOISE REJECTION
NMR: 130 dB, 50/60 Hz
CMR: 120 dB, DC to 60hZ
CMV: 1500 Vp per HV test, 354 Vp per IEC spacing
ACCURACY AT 25°C
Maximum Error: ±0.05% of reading ±2 counts
Span tempco: ±0.01% of reading/°C
Step response: 1 s to 99.9% of span
Warmup to rated accuracy: 30 min
CONVERSION
Technique: Dual-slope, average-value
Signal integration period: 100 ms
Read rate: 2.5/s
DISPLAY
Type: 7-segment, red LED
Height: 0.56 in (14.2 mm)
Symbols: 8.8.8.8
Decimal points: Three positions selectable by jumpers behind
lens or at connector
0 to ±9,999 counts: Normal operation
±10,000 to ±19,999 counts: Four least-significant
digits flash reading
Beyond ±19,999 counts: All four digits flash zeros
POWER
AC voltages: 120, 240 or 24 V ac +10%/15%
AC frequency: 49-440 Hz
DC voltages: 9-32 V dc, isolated to 300 Vp; 26-56 V dc, isolated
to 300 Vp; 5 V dc ±5%, non-isolated
Power consumption: 8 W max
ENVIRONMENTAL
Operating temperature: 0 to 60°C
Storage temperature: 40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)
MECHANICAL
Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical
section for drawings)
Weight: 17 oz (480 g)
Case material: 94V-0 UL-rated polycarbonate
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Display Resolution and Case Style
|
| |
Select 9 for ±9,999 counts (4 digits) 8 for ±9,999 with INFINITY FAMILY BEZEL AND ADAPTER
|
(2)
|
Display Type & Meter Power - LCD
|
| |
Select 0 for LED, 120 Vac (49/440 Hz) (BQ20 or BQ90) 1 for LCD, 120 Vac (49/440 Hz) (BQ21) 2 for LED, 240 Vac (49/440 Hz) (BQ22 or BQ92) 3 for LCD, 240 Vac (49/440 Hz) (BQ23) 4 for LED, 9-32 Vdc (isolated) (BQ24 or BQ94) 5 for LCD, 9-32 Vdc (isolated) (BQ25) 6 for LED, 5 Vdc** (BQ26 or BQ96) 7 for LCD, 5 Vdc** (BQ27) 8 for LED, 24 Vac (BQ28 or BQ98) 9 for LCD, 24 Vac (BQ29) A for LED, 26-56 Vdc (isolated) (BQ2A or BQ9A) B for LCD, 26-56 Vdc (isolated) (BQ2B)
|
(3)
|
Analog Output Adders
|
| |
Select 0 for ±1 or ±2 V recorder output, non-isolated. (standard) 1 for 0-5 Vdc, non-isolated (BA01) 2 for 0-10 Vdc, non-isolated (BA01) 3 for 0-1 mA, source or sink, non-isolated (BA01) 4 for 4-20 mA, source or sink, non-isolated (BA01) 5 for 4-20 mA, sink (high-compliance), non-isolated. (BA02) 6 for 4-20 mA, ISOLATED (BA03)
|
(4)
|
Control Output Adders
|
| |
Select 0 for None 1 for Dual-setpoint 10 A relay. (BDT1) 2 for Proportional 4-20 mA control, source or sink (BDP1) 3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control, source or sink. (BDP2) 4 for BCD (isolated, latched, buffered, byte addressable). Includes 50-pin mass-termination connector. (BDD2) 5 for Single-setpoint 10 A relay (BDS1)
|
(5)
|
Signal Conditioning Input Adders
|
| |
Select AVR1 for DC Voltage ±99.99 mV AVR2 for DC Voltage ±999.9 mV AVR3 for DC Voltage ±9.999 V AVR4 for DC Voltage ±99.99 V BCR1 for DC Current ±9.999 µA BCR2 for DC Current ±99.99 µA BCR3 for DC Current ±999.9 µA BCR4 for DC Current ±9.999 mA BCR5 for DC Current ±99.99 mA BCR6 for DC Current ±999.9 mA
|
(6)
|
Display Color
|
| |
Select Nothing(leave field blank) for Red Display (standard) ,G for Green Display
|
(7)
|
Lens
|
| |
Select Nothing(leave field blank) for Standard Lens (with Newport logo) ,BL for Blank Lens
|