RTD Elements with Lead Wires Attached
RTD-2

All of NEWPORT’s
RTD elements can be supplied with additional lead wire attached
to existing leads. Longer leads create more flexibility for use
in many applications. |
| Features |
 |
Made
From Class B, 100 ohm, 0.00385 Curve Elements |
 |
2-,
3- or 4-Wire Lead Configurations |
 |
26
AWG Stranded Nickel-Plated Copper Leads, 36" Long |
 |
Most
Common Assemblies Shown Below |
For additional specifications on the elements in this section
(i.e., dimensions, accuracy, ohm value, etc.), The size of the
potted junction between lead wire and element is kept as small
as possible. Note: These elements are not intended for
direct immersion into liquids. |
RTD Elements
with Attached Lead Wires
|
Model
No.*
|
RTD
Element Used
|
Lead
Wire Insulation
|
Potting
Material
|
Max.
Temp.
|
|
RTD-2-F3105-36-T
|
F3105
|
PFA
|
Epoxy
|
450°F (230°C)
|
|
RTD-2-F3105-36-G
|
F3105
|
Glass
|
Cement
|
900°F (480°C)
|
|
RTD-2-F3105-36-B
|
F3105
|
Bare
|
Cement
|
1112°F (600°C)
|
|
RTD-2-F3102-36-T
|
F3102
|
PFA
|
Epoxy
|
450°F
(230°C)
|
|
RTD-2-F3102-36-G
|
F3102
|
Glass
|
Cement
|
900°F
(480°C)
|
|
RTD-2-F3102-36-B
|
F3102
|
Bare
|
Cement
|
1112°F
(600°C)
|
|
RTD-2-1PT100K2515-36-T
|
1PT100K2515
|
PFA
|
Epoxy
|
450°F
(230°C)
|
|
RTD-2-1PT100K2515-36-G
|
1PT100K2515
|
Glass
|
Cement
|
900°F
(480°C)
|
|
RTD-2-1PT100K2515-36-B
|
1PT100K2515
|
Bare
|
Cement
|
1562°F
(850°C)
|
|
RTD-2-1PT100KN2528-36-T
|
1PT00KN2528
|
PFA
|
Epoxy
|
450°F
(230°C)
|
|
RTD-2-1PT100KN2528-36-G
|
1PT100KN2528
|
Glass
|
Cement
|
900°F
(480°C)
|
|
RTD-2-1PT100KN2528-36-B
|
1PT100KN2528
|
Bare
|
Cement
|
1220°F
(661°C)
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: These elements are not intended for direct immersion into liquids. Style 2 is standard wire configuration. To order style 1 (2-wire), replace the “-2-” with “-1-”in the model number. To order style 3 (4-wire), replace the “-2-” with “-3-” in the model number. For leads over 36", change the “36” in the model number to length desired in inches and add $2.25/ft (Styles 2 & 3) or $1.40/ft (Style 1). Other RTD elements are also available with lead wire attached see others in the RTD-(*) series or consult Sales for availability and pricing. Terminations available: “-LUG”, add $4.50. For miniature connectors, use suffix “-MTP” or “-OTP” for standard size connectors, and add $7. (OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) RTD-2-F3105-36-T F3105 element with 36" of PFA-insulated leads attached = $45
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Wire Style
|
| |
Select 2 for 3-wire (standard) 1 for 2-wire 3 for 4-wire
|
(2)
|
Element
|
| |
Select F3105 for 2x2 mm 100 ohm thin film element F3102 for 4x5 mm 100 ohm thin film element 1PT100K2515 for 25 mm l x 1.5 mm dia 100 ohm wire wound element 1PT100KN2528 for 25 mm l x 1.5 mm dia 100 ohm wire wound element
|
(3)
|
Cable Length
|
| |
Select 36 for 40 inch (1 m) standard
|
(4)
|
Lead Wire Insulation Type
|
| |
Select T for PFA G for Fiberglass B for Bare
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | |
|
 |
 |
|
|
|
|