Thermocouple Wire - Special Limits of Error

Special Limits of Error for Thermocouples: 1
Model #
AWG
GG-J-20-SLE
20
GG-J-24-SLE
24
TT-J-20-SLE
20
TT-J-24-SLE
24
Thermocouple Type
Temp Range °C
Temp Range °F
Special Limits of Error(2)
T
0 to 350
32 to 662
±0.5°C or 0.4%
J
0 to 750
32 to 1382
±1.1°C or 0.4%
E
0 to 900
32 to 1652
±1.0°C or 0.4%
K
0 to 1250
32 to 2282
±1.1°C or 0.4%
1ANSI MC96.1 (1975)
2Whichever is greater


Model #
AWG
GG-K-20-SLE
20
GG-K-24-SLE
24
TT-K-20-SLE
20
TT-K-24-SLE
24
Model #
AWG
GG-T-20-SLE
20
GG-T-24-SLE
24
TT-T-20-SLE
20
TT-T-24-SLE
24
Model #
AWG
GG-E-20-SLE
20
GG-E-24-SLE
24
TT-E-20-SLE
20
TT-E-24-SLE
24
GG=Glass/Glass
TT=PFA/PFA

High Temperature Silfa Silica also available

NEWPORT will overbraid any thermocouple wire with Inconel 600, 304 SS or tinned copper overbraiding. Both Inconel 600 and SS add durability and abrasion protection. Consult Sales Department.



To Order (Specify Model Number, see variations below in partnumber builder table)    
 Part Number   Availability   Price    Description    Qty.
 GG-K-20-SLE-1000 1 Week    $610.00     1000 ft., Type K, 20 AWG, Fiberglass Insulated Thermocouple Wire, Special Limits of Error  
 GG-K-24-SLE-100 1 Week    $70.00     100 ft, Type K, 24 AWG, Fiberglass Insulated Thermocouple Wire, Special Limits of Error  
 TT-K-24-SLE-25 1 Week    $32.00     25 ft., Type K, 24 AWG, PFA Polymer Insulated Thermocouple Wire, Special Limits of Error  
 TT-J-24-SLE-1000 1 Week    $405.00     1000 ft., Type J, 24 AWG, PFA Polymer Insulated Thermocouple Wire, Special Limits of Error  
 GG-T-20-SLE-500 1 Week    $215.00     500 ft., Type T, 20 AWG, Fiberglass Insulated Thermocouple Wire, Special Limits of Error  
 TT-T-24-SLE-50 1 Week    $42.00     50 ft., Type T, 24 AWG, PFA Polymer Insulated Thermocouple Wire, Special Limits of Error  
 
All dollar amounts on this site are shown in US currency.

 Part Number Builder
(1) (2) (3) (4)
-SLE-
Option Descriptions
(1)
  Select
GG for Glass/Glass
TT for PFA
(2) Calibration
  Select
-T for 0-350°C (32-662°F)
-J for 0-750°C (32-1382°F)
-E for 0-900°C (32-1652°F)
-K for 0-1250°C (32-2282°F)
-N for 270 to 1300°C (450 to 2372°F)
(3) AWG Number
  Select
-20 for 0.81mm (0.032inch) Diameter
-24 for 0.51mm (0.020inch) Diameter
(4) Length
  Select
25 for 7.5m (25ft)
50 for 15m (50ft)
100 for 30m (100ft)
200 for 60m (200ft)
500 for 150m (500ft)
1000 for 300m (1000ft)
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   