Thermocouple Wire - Duplex Insulated
CHROMEGA®-Constantan Duplex
ANSI Type E
ANSI Color Code:
Positive Wire, Purple; Negative Wire, Red; Overall, Brown
NEWPORT Electronics does not use reprocessed PFA, FEP or PVC in manufacturing thermocouple wire.
|
|
|
Insulation1
|
Model
#
|
AWG
|
Type
Wire
|
Insulation
|
Max.
Temp
|
Nominal
Size
|
Wt.†
lb/1000'
|
|
Conductor
|
Overall
|
°F
|
°C
|
|
Ceramic*
|
XC-E-14
|
14
|
Solid
|
Nextel
Ceramic
|
1200
|
650
|
.140
x .200
|
38
|
|
XC-E-20
|
20
|
1000
|
540
|
.135
x .190
|
16
|
|
XT-E-20
|
20
|
.105
x .155
|
15
|
|
XL-E-20
|
20
|
.095
x .135
|
14
|
|
XC-E-24
|
24
|
800
|
430
|
.115
x .175
|
12
|
|
XT-E-24
|
24
|
.088
x .132
|
11
|
|
XL-E-24
|
24
|
.078
x .116
|
10
|
|
Silica*
|
XS-E-14
|
14
|
Solid
|
Silica
|
1200
|
650
|
.140
x .200
|
35
|
|
XS-E-20
|
20
|
1000
|
540
|
.105
x .155
|
12
|
|
XS-E-24
|
24
|
800
|
430
|
.088
x .132
|
10
|
|
High
Temp. Glass**
|
HH-E-20
|
20
|
Solid
|
High
Temp. Glass
|
1000
|
540
|
.060
x .105
|
9
|
|
HH-E-24
|
24
|
800
|
430
|
.055
x .090
|
5
|
|
Glass
|
GG-E-20
|
20
|
Solid
|
Glass
Braid
|
Glass
Braid
|
900
|
482
|
.060
x .095
|
9
|
|
GG-E-20S
|
20
|
7
X 28
|
.060
x .100
|
9
|
|
GG-E-24
|
24
|
Solid
|
800
|
430
|
.050
x .080
|
5
|
|
GG-E-24S
|
24
|
7
X 32
|
.050
x .085
|
5
|
|
GG-E-26
|
26
|
Solid
|
.045
x .075
|
4
|
|
GG-E-30
|
30
|
Solid
|
Glass
Wrap
|
700
|
320
|
.037
x .050
|
3
|
|
GG-E-36
|
36
|
Solid
|
.033
x .043
|
2
|
|
PFA
(High Performance)
|
TT-E-20
|
20
|
Solid
|
PFA
|
500
|
260
|
.068
x .116
|
11
|
|
TT-E-20S
|
20
|
7
X 28
|
.073
x .126
|
11
|
|
TT-E-22S
|
22
|
7
X 30
|
.065
x .133
|
9
|
|
TT-E-24
|
24
|
Solid
|
.056
x .092
|
6
|
|
TT-E-24S
|
24
|
7
X 32
|
.063
x .102
|
6
|
|
TT-E-30††
|
30
|
Solid
|
.024
x .040
|
2
|
|
TT-E-36††
|
36
|
Solid
|
.019
x .030
|
2
|
|
TT-E-40††
|
40
|
Solid
|
.017
x .026
|
2
|
|
FEP
|
FF-E-20
|
20
|
Solid
|
FEP
|
392
|
200
|
.068
x .116
|
11
|
|
FF-E-24
|
24
|
.056
x .092
|
6
|
1
Additional Type E insulated wires are available. See Fused Tape Insulated
TFE-E.
†Weight of spool and wire rounded up to the next highest lb. (does not include packing material).
††Overall color clear
*Has color tracers on jacket and conductors
**Has trace thread in Positive leg, Negative leg is red, overall has trace thread.
*** Two insulated leads bonded together, but with no overwrap.
Some wires available with Special Limits of Error; consult Sales for pricing and availability.
Ceramic Weave Note: |
XC |
standard ceramic insulation with maximum insulation density. |
XT |
more tightly woven with reduced insulation density. |
XL |
loosely woven with the minimum insulation density. |

NEWPORT can cover any insulated wire in our handbook with metal overbraiding to protect against wear and abrasion. Overbraiding adds durability and electrical shielding for improved performance.
|
|
|
† All dollar amounts on this site are shown in US currency.
Ordering Example: (1) GG-E-20-1000 1000 ft, Glass Insulated, 20 AWG, Type E = $540
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Insulation
|
| |
Select HH for High Temp Glass (20 & 24 AWG Only) GG for Glass TT for Neoflon PFA (High Performance) FF for Neoflon FEP (20 & 24 AWG Only) XC for Ceramic(14 20 24 AWG Only) XT for Ceramic(20 & 24 AWG Only) XL for Ceramic(20 & 24 AWG Only) XS for Silica (14 20 24 AWG Only)
|
(2)
|
Gage
|
| |
Select 20 for 20 AWG 20S for 20 AWG (Stranded) 24 for 24 AWG 24S for 24 AWG (Stranded) 30 for 30 AWG 36 for 36 AWG 40 for 40 AWG
|
(3)
|
Spool Length
|
| |
Select 25 for 25 Feet 50 for 50 Feet 100 for 100 Feet 200 for 200 Feet 500 for 500 Feet 1000 for 1000 Feet
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| |
|
 |
 |
|
|
|
|
Keywords: E Type Duplex Insulated Thermocouple Wire
|