New wSeries Wi-Fi transmitters
You can view charts and graphs, monitor and record readings from virtually any
type of transducer over an Ethernet network or the Internet from any computer,
tablet, or smart phone with a Web browser.
The Wi-Fi transmitters are powered by your choice of batteries or AC. The battery
version comes with two ordinary alkaline C-CELL batteries that can last for two
years depending on the frequency of readings. The AC version comes with a
universal AC adapter that operates on any voltage worldwide (110 to 240 VAC)
and also includes an alkaline AA backup battery.
The
wSeries Wi-Fi transmitters are designed for demanding industrial applications and
harsh outdoor environments. The electronics are protected in a rugged
weatherproof, polycarbonate NEMA4/IP65 rated housing.
CHARTS AND GRAPHS
The NEWPORT® wSeries system serves Active Web
Pages to display real time readings and charts of Analog
Voltage and Current, Temperature, Humidity, and
Barometric Pressure. You can also log data in standard
data formats for use in a spreadsheet or data acquisition
program such as Excel or Visual Basic.
Chart scales are fully adjustable on the fly. For example,
the chart can display one minute, one hour, one day, one
week, one month or one year. Temperature and humidity
can be charted across the full span (-40 to 125°C, and
0 to 100% RH) or within any narrow range such as
(20 to 30°C). NEWPORT offers an OPC Server software
($295) that makes it easy to integrate the wSeries
wireless sensor system with many popular Data
Acquisition and Automation programs offered by
NEWPORT, Wonderware, iConics, Intellution, Rockwell
Automation, and National Instruments, among others.
| |
 |
 |
|
ALARM AND EMAIL
The wSeries wireless sensor system can trigger an alarm
if variables go above or below a set point that you
determine. You can even set alarms to be notified by email. Alarms can be sent to a single
user or to a group distribution list, including text messages to cell phones.
QUALITY and TECHNOLOGY
The innovative
NEWPORT® wSeries system features an extended one
(1) YEAR warranty at no extra charge.
|
|
SPECIFICATIONS
EXTERNAL SENSOR SPECIFICATIONS
RELATIVE HUMIDITY
Accuracy/Range: wTHP, wTHP2, wBTHP
±2% for 10 to 90%;
±3% for 5 to 10% and 90 to 95%;
±4% for 0 to 5% and 95 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Repeatability: ±0.1%
Resolution: 0.1%
TEMPERATURE
Accuracy/Range*: wTHP, wTHP2
±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 124°C
(up to ±2.7°F for -40 to 41°F and 113 to 255°F)
wTP1, WTP2
±0.5°C for 10 to 85°C (±0.9°F for 50 to 185°F);
±1°C for -40 to 10°C and 85 to 125°C
(±1.8°F for -40 to 50°F and 185 to 257°F)
wBTHP
±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 85°C
(up to ±2.7°F for -40 to 41°F and 113 to 185°F)
wBTP
±0.8°C @ 25ºC (±1.5°F @ 77ºF)
±4°C for -40 to 85°C (±7.2°F for -40 to 185ºF)
*Note: extended temperature range is for External Probe only.
Resolution: 0.1ºC
BAROMETRIC PRESSURE
Accuracy/Range: wBTP, wBTHP
±2 mbar for 300 to 1100 mbar @ 0 to 50°C
±6 mbar for 300 to 1100 mbar @ -40 to 85°C
Resolution: 0.1 mbar
ANALOG VOLTAGE & CURRENT INPUT (wVI)
Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V
Input Impedance: 38 K ohm for voltage
Current Input: Differential; bipolar; ±20 mA (5 Ohm load)
Accuracy: ±0.1% Full Range @ 25°C
Reading Rate: Periodic (1 sample/update) or continuous
(3 samples/second)
A/D Conversion: Sigma-Delta
Resolution: 16 bits
Temperature Coefficient: ±50 ppm/°C
Common Mode Rejection: 105 dB
Normal Mode Rejection: 98 dB
Warm-Up to Rated Accuracy: 30 minutes
THERMOCOUPLE INPUT (wTC)
Temperature Range: refer to Thermocouple Chart
Temperature Accuracy: refer to Thermocouple Chart
Temperature Stability: 0.08°C/°C
Temperature Coefficient: ±25 ppm/°C
Thermocouple Cold End Tracking: 0.1°C/°C
Thermocouple Lead Resistance: 100 ohm max.
Thermocouple Type (ITS 90):
J, K, T, E, R, S, B, C, N, L (DIN J)
Warm-Up to Rated Accuracy: 30 minutes
Reading Rate: Periodic (1 sample/update) or continuous
(3 samples/second)
 |
|
METER SPECIFICATIONS
Supported Protocols Transmitter:
TCP/IP, UDP, ARP, ICMP, DHCP,
HTTP and FTP
Supported Protocols VC:
TCP/IP, UDP, HTTP, FTP, SMTP and
Telnet
WIRELESS COMMUNICATION
Standard: IEEE 802.11 b/g / Wi-Fi
Frequency: 2.4 GHz (2402~2480 MHz)
Range: Up to 100m (330') depending
upon environmental considerations.
Radio Power Output Level (Class 1):
20 dBm
Modulation:
802.11b Compatibility: DSSS
(CCK-11, CCK-5.5, DQPSK-2, DBPSK-1)
802.11g: OFDM (default)
Channels: 1-14
Channel Interval: 5MHz
Transmission Rate (Over the Air):
802.11b: 1 to 11 Mbps
802.11g: 6 to 54 Mbps
Receiver Sensitivity: -85 dBm, typ.
POWER
Power Input:
wVI: 9 Vdc
All Others: 5 Vdc
Consumption:
wVI: 1.3 W max
All Others: 0.7 W max
Safety Qualified
AC Power Adapter
(included)
Nominal Output:
5 Vdc @ 0.6 A or
9 Vdc @ 0.5 A (wVI )
Input:
100 to 240 Vac,
50/60 Hz
Back-up Alkaline Battery:
One AA 1.5 Vdc, supplied

Universal ac Power Adapter
POWER (wSeries-CCELL)
Alkaline Battery:
Two C-CELL 1.5 Vdc, supplied
Lifetime:
Estimate of 2.4 years (wTC/wVI) and 4.3 years (wTxxP/wBxxP) with frequency of 1 reading per 1 minute (see Chart)
 | | Battery life is dependent on environmental conditions and transmitter settings. |
ENCLOSURE PACKAGING
Material: Polycarbonate Sabiclexan
Protection: NEMA4/IP65 rated housing
Dimensions:
96.5H x 146.3W x 50.8D mm
(3.8 x 5.76 x 2"), not including
connectors or antenna
GENERAL
Approvals:
FCC Part 15C;
CE EMC; 2004/108/EC,
LVD 2006/95/EC,
R&TTE 1999/5/EC
Operating Temperature:
-10 to 55ºC (14 to 131ºF), 90% RH
non-condensing
AC Power Adapter: 0 to 40ºC (32 to 104ºF)
|
Click chart for detailed Battery Lifetimes

 | | Battery life is dependent on environmental conditions and transmitter settings. |

Mechanical Dimensions
Quick Disconnect Connectors & Cable Gland usage
Thermocouple Chart
|
Input Type |
Range |
Accuracy |
J |
Iron-Constantan |
-210 to 760°C / -346 to 1400°F |
0.5°C / 0.9°F |
K |
CHROMEGA®-ALOMEGA® |
-230 to -180°C / -180 to 1372°C
-382 to -292°F / -292 to 2502°F |
1.0°C / 0.5°C
1.8°F / 0.9°F |
T |
Copper-Constantan |
-240 to -180°C / -180 to 400°C
-400 to -292°F / -292 to 752°F |
1.0°C / 0.5°C
1.8°F / 0.9°F |
E |
CHROMEGA®-Constantan |
-250 to -220°C / -220 to 1000°C
-418 to -364°F / -364 to 1832°F |
1.0°C / 0.5°C
1.8°F / 0.9°F |
R |
Pt/13%Rh-Pt |
310 to 1768°C
590 to 3214°F |
1.0°C
1.8°F |
S |
Pt/10%Rh-Pt |
400 to 1768°C
752 to 3214°F |
1.0°C
1.8°F |
B |
30%Rh-Pt/6%Rh-Pt |
470 to 1050°C / 1050 to 1820°C
878 to 1922°F / 1922 to 3308°F |
2.0°C / 1.0°C
3.6°F / 1.8°F |
C |
5%Re-W/26%Re-W |
0 to 450°C / 450 to 790°F
790 to 2280°C / 32 to 842°F
842 to 1454°C / 1454 to 4136°F |
1.0°C / 0.5°F
1.0°C / 1.8°F
0.9°C / 1.8°F |
N |
Nicrosil-Nisil |
-200 to -120°C / -120 to 1300°C
-328 to -184°F / -184 to 2372°F |
1.0°C / 0.5°C
1.8°F / 0.9°F |
L |
J DIN |
-200 to 900°C / -328 to 1652°F |
0.5°C / 0.9°F |

Replacement Probes and Calibration Certificates
No need to take your unit out of service to get re-calibrated, order a calibrated probe instead.

Get a NIST Traceable Calibration Certificate with your Calibrated Replacement Probe.
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 2 "CCELL" batteries or AC power adaptor, and "AA" backup battery.
Note: Because of transmission frequency regulations, these products may only be used in the United States, Canada and Europe.
Ordering Example: (1) CAL-3-T a NIST Traceable Calibration Certificate for your new unit, (1) zTP1-P For a replacement external stick probe, (1) zTP1-CAL-3-T For a calibrated replacement probe including Calibration Certificate: $50 + 50 = $260
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
External Sensors
|
| |
Select TP1 for Temperature Stick Probe TP2 for Temperature Lug Mount Probe THP for Humidity + Temperature Industrial Probe THP2 for Short Quick-Disconnect Humidity + Temperature Probe BTHP for Barometric Pressure + Temperature + Humidity Industrial Probe BTP for Barometric Pressure + Temperature Industrial Probe TC for Dual Thermocouple Input VI for Analog Process Voltage and Current Input
|
(2)
|
Power and Display Options
|
| |
Select Nothing(leave field blank) for AC power with back-up battery -LCD for AC power and LCD Display -CCELL for Power with two C-cell alkaline batteries -LCD-CCELL for Power with two C-cell alkaline batteries and LCD Display
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
|
|
 |
 |
|
|
|
|
Keywords:Wi-Fi Wireless Sensor transmitter wireless ethernet sensor system web based monitoring temperature humidity barometric pressure virtual coordinator
|
Back to top |
|
| |